Pepperl Fuchs IC-KP-B6-SUBD
Request a Quote
Quick facts
| Availability | Confirmed on request |
| Category | RFID Evaluation Units |
| Lifecycle | active |
| Warranty | 12-month (new) · 3-month (used/refurbished) |
Shipping & availability
When can IC-KP-B6-SUBD be shipped?
IC-KP-B6-SUBD is sourced on request — request a quote and we'll confirm the exact availability and shipping timeline for this specific unit.
Can I pick up IC-KP-B6-SUBD in person?
Local pickup from our Groningen, Netherlands warehouse may be possible — contact us before ordering to check availability and arrange a collection time.
Is express delivery available?
Yes — mention it when you request a quote for IC-KP-B6-SUBD and we'll include express shipping options in our reply.
My factory is down and I need this urgently — can you help?
For a critical breakdown, contact us directly at +31 (0)50-7110348 or sales@partnerplc.com — we can look into same-day courier or dedicated taxi/hotshot delivery for IC-KP-B6-SUBD, subject to availability and destination.
RFID evaluation unit. Control interface unit IDENTControl with PROFIBUS DP interface. Number of read/write heads: max. 4alternative 2 read/write heads and 2 trigger sensors. UL File Number: E87056. LEDs 1, 2, 3, 4: Status indicator for read/write headsgreen: command at read/write head activeyellow: approx. 1 second long, if command was successfully executed. LED PWR/ERR: green: power onred: Hardware fault. LED UL: green: Interface Power ON/OK. LED Bus Error: red: Bus error. LED Data Exch: green: Slave is at state "Data Exchange". LED DPV1: Yellow: not used. LC display: two-line multi-function display with 12 characters per line configuration of the control interface and display of connected read/write heads as additional pictograms; easy and direct selection of operating commands and addressing. Button: 4 keys: ESC, up, down and return. Rated operating voltage: 20 ... 30 V DC , PELV. Ripple: ≤ 10 % at 30 V DC. Current consumption: ≤ 2 A incl. read/write heads. Power consumption: 3.5 W Without read/write heads. Galvanic isolation: basic insulation acc. to DIN EN 50178, rated insulation voltage of 50 Veff. Physical: RS-485. Protocol: PROFIBUS DP acc. to EN 50170. Transfer rate: 9.6; 19.2; 93.75; 187.5; 500; 1500 kBit/s 3; 6; 12 Mbit/s self-synchronizing. Electromagnetic compatibility: . Directive 2014/30/EUEN 61326-1: . Directive 2014/30/EU: EN 61326-1. RoHS: . Directive 2011/65/EU (RoHS)IEC/EN 63000: . Directive 2011/65/EU (RoHS): IEC/EN 63000. Degree of protection: IEC 60529. Ambient temperature: -25 ... 70 °C (-13 ... 158 °F). Storage temperature: -30 ... 80 °C (-22 ... 176 °F). Climatic conditions: air humidity max. 96 %. Shock and impact resistance: Oscillation (Sine): 5 g, 10 - 1000 Hz to EN 60068-2-6Shock (Half-sine): 30 g, 11 ms in accordance with EN 60068-2-27. Degree of protection: IP40. Connection: Read/write heads: shielded, 4-pin, M12 connector Power supply: M12 connector Protective earth: M6 earthing screw PROFIBUS: 9-pin Sub-D connector. Material: . Housingpowder coated aluminum: . Housing: powder coated aluminum. Installation: snap-on to 35 mm standard rail or screw fixing. Mass: approx. 1000 g. Dimensions: . Height73 mmWidth105 mmLength148 mm: . Height: 73 mm. Width: 105 mm. Length: 148 mm
Specifications
General specifications
| Number of read/write heads | max. 4alternative 2 read/write heads and 2 trigger sensors |
| UL File Number | E87056 |
Indicators/operating means
| LEDs 1, 2, 3, 4 | Status indicator for read/write headsgreen: command at read/write head activeyellow: approx. 1 second long, if command was successfully executed |
| LED PWR/ERR | green: power onred: Hardware fault |
| LED UL | green: Interface Power ON/OK |
| LED Bus Error | red: Bus error |
| LED Data Exch | green: Slave is at state "Data Exchange" |
| LED DPV1 | Yellow: not used |
| LC display | two-line multi-function display with 12 characters per line configuration of the control interface and display of connected read/write heads as additional pictograms; easy and direct selection of operating commands and addressing |
| Button | 4 keys: ESC, up, down and return |
Electrical specifications
| Rated operating voltage | 20 ... 30 V DC , PELV Ue |
| Ripple | ≤ 10 % at 30 V DC |
| Current consumption | ≤ 2 A incl. read/write heads |
| Power consumption | 3.5 W Without read/write heads P0 |
| Galvanic isolation | basic insulation acc. to DIN EN 50178, rated insulation voltage of 50 Veff |
Interface
| Physical | RS-485 |
| Protocol | PROFIBUS DP acc. to EN 50170 |
| Transfer rate | 9.6; 19.2; 93.75; 187.5; 500; 1500 kBit/s 3; 6; 12 Mbit/s self-synchronizing |
Directive conformity
| Electromagnetic compatibility | |
| Directive 2014/30/EUEN 61326-1 | Directive 2014/30/EU |
| Directive 2014/30/EU | EN 61326-1 |
| RoHS | |
| Directive 2011/65/EU (RoHS)IEC/EN 63000 | Directive 2011/65/EU (RoHS) |
| Directive 2011/65/EU (RoHS) | IEC/EN 63000 |
Standard conformity
| Degree of protection | IEC 60529 |
Ambient conditions
| Ambient temperature | -25 ... 70 °C (-13 ... 158 °F) |
| Storage temperature | -30 ... 80 °C (-22 ... 176 °F) |
| Climatic conditions | air humidity max. 96 % |
| Shock and impact resistance | Oscillation (Sine): 5 g, 10 - 1000 Hz to EN 60068-2-6Shock (Half-sine): 30 g, 11 ms in accordance with EN 60068-2-27 |
Mechanical specifications
| Degree of protection | IP40 |
| Connection | Read/write heads: shielded, 4-pin, M12 connector Power supply: M12 connector Protective earth: M6 earthing screw PROFIBUS: 9-pin Sub-D connector |
| Material | |
| Housingpowder coated aluminum | Housing |
| Housing | powder coated aluminum |
| Installation | snap-on to 35 mm standard rail or screw fixing |
| Mass | approx. 1000 g |
| Dimensions | |
| Height73 mmWidth105 mmLength148 mm | Height |
| Height | 73 mm |
| Width | 105 mm |
| Length | 148 mm |