Pepperl Fuchs HiD-ADP-HiC-DI
Request a Quote
Quick facts
| Availability | Confirmed on request |
| Category | H-System (Termination Board Mounting) |
| Lifecycle | active |
| Warranty | 12-month (new) · 3-month (used/refurbished) |
Shipping & availability
When can HiD-ADP-HiC-DI be shipped?
HiD-ADP-HiC-DI is sourced on request — request a quote and we'll confirm the exact availability and shipping timeline for this specific unit.
Can I pick up HiD-ADP-HiC-DI in person?
Local pickup from our Groningen, Netherlands warehouse may be possible — contact us before ordering to check availability and arrange a collection time.
Is express delivery available?
Yes — mention it when you request a quote for HiD-ADP-HiC-DI and we'll include express shipping options in our reply.
My factory is down and I need this urgently — can you help?
For a critical breakdown, contact us directly at +31 (0)50-7110348 or sales@partnerplc.com — we can look into same-day courier or dedicated taxi/hotshot delivery for HiD-ADP-HiC-DI, subject to availability and destination.
Adapter Set for HiD Termination Board. Set consisting of isolated barrier HiC2822 and adapter HiD-ADP-HiC, 2-channel isolated barrier, 24 V DC supply (bus powered), Dry contact or NAMUR inputs, 2 relay contact outputs, For HiD Termination Board mounting, Up to SIL 2 acc. to IEC/EN 61508, Signal type: Digital Input, Safety Integrity Level (SIL): SIL 2, Field device: NAMUR sensor, Type: 2 x relay (NO contact). Signal type: Digital Input. Safety Integrity Level (SIL): SIL 2. Rated voltage: 19 ... 30 V DC bus powered via Termination Board. Rated current: ≤ 30 mA. Power dissipation: ≤ 600 mW. Power consumption: ≤ 600 mW. Connection side: field side. Open circuit voltage/short-circuit current: approx. 10 V DC / approx. 8 mA. Switching point/switching hysteresis: 1.2 ... 2.1 mA / approx. 0.2 mA. Line fault detection: breakage I ≤ 0.1 mA , short-circuit I ≥ 6.7 mA. Connection side: control side. Output I: signal ; relay. Output II: signal ; relay. Output type: open collector transistor (internal fault bus). Display elements: LEDs. Control elements: DIP switch. Configuration: via DIP switches. Labeling: space for labeling at the front. Electromagnetic compatibility: . Directive 2014/30/EUsee datasheet of isolated barrier: . Directive 2014/30/EU: see datasheet of isolated barrier. Electromagnetic compatibility: see datasheet of isolated barrier. Degree of protection: IEC 60529. Ambient temperature: -20 ... 60 °C (-4 ... 140 °F). Degree of protection: IP20. Mass: approx. 200 g. Dimensions: 18 x 106 x 168 mm (0.7 x 4.2 x 6.6 inch) (W x H x D). Mounting: on termination board. EU-type examination certificate: see datasheet of isolated barrier. UL approval: see datasheet of isolated barrier. IECEx approval: . IECEx certificatesee datasheet of isolated barrier: . IECEx certificate: see datasheet of isolated barrier. Supplementary information: Observe the certificates, declarations of conformity, instruction manuals, and manuals where applicable. For information see www.pepperl-fuchs.com.
Specifications
General specifications
| Signal type | Digital Input |
Functional safety related parameters
| Safety Integrity Level (SIL) | SIL 2 |
Supply
| Rated voltage | 19 ... 30 V DC bus powered via Termination Board Ur |
| Rated current | ≤ 30 mA Ir |
| Power dissipation | ≤ 600 mW |
| Power consumption | ≤ 600 mW |
Input
| Connection side | field side |
| Open circuit voltage/short-circuit current | approx. 10 V DC / approx. 8 mA |
| Switching point/switching hysteresis | 1.2 ... 2.1 mA / approx. 0.2 mA |
| Line fault detection | breakage I ≤ 0.1 mA , short-circuit I ≥ 6.7 mA |
Output
| Connection side | control side |
| Output I | signal ; relay |
| Output II | signal ; relay |
Fault indication output
| Output type | open collector transistor (internal fault bus) |
Indicators/settings
| Display elements | LEDs |
| Control elements | DIP switch |
| Configuration | via DIP switches |
| Labeling | space for labeling at the front |
Directive conformity
| Electromagnetic compatibility | |
| Directive 2014/30/EUsee datasheet of isolated barrier | Directive 2014/30/EU |
| Directive 2014/30/EU | see datasheet of isolated barrier |
Conformity
| Electromagnetic compatibility | see datasheet of isolated barrier |
| Degree of protection | IEC 60529 |
Ambient conditions
| Ambient temperature | -20 ... 60 °C (-4 ... 140 °F) |
Mechanical specifications
| Degree of protection | IP20 |
| Mass | approx. 200 g |
| Dimensions | 18 x 106 x 168 mm (0.7 x 4.2 x 6.6 inch) (W x H x D) |
| Mounting | on termination board |
Data for application in connection with hazardous areas
| EU-type examination certificate | see datasheet of isolated barrier |
International approvals
| UL approval | see datasheet of isolated barrier |
| IECEx approval | |
| IECEx certificatesee datasheet of isolated barrier | IECEx certificate |
| IECEx certificate | see datasheet of isolated barrier |
General information
| Supplementary information | Observe the certificates, declarations of conformity, instruction manuals, and manuals where applicable. For information see www.pepperl-fuchs.com. |
More Pepperl Fuchs parts
NewPepperl + Fuchs KFD2-GUT-EX1.D New open box
Available on requestPepperl Fuchs V19-W-BK15M-PUR-U-V19-G
Available on requestPepperl Fuchs V1SD-G-GN65M-PUR-E1S-V45-G