What is the Pepperl Fuchs HiCTB16-YC3-RRB-KS-CC-AM16-Y2?

System board for Yokogawa CENTUM VP

For 16-channel AI/AO card AAB842-H

For 16 modules

Recommended modules: HiC2025(A) (AI), HiC2031 (AO), HiC2081(TI)

24 V DC supply

Hazardous area: spring terminals, blue

Non-hazardous area: Yokogawa system connector, 40-pin

System board for Yokogawa CENTUM VP, For 16-channel AI/AO card AAB842-H, For 16 modules, Recommended modules: HiC2025(A) (AI), HiC2031 (AO), HiC2081(TI), 24 V DC supply, Hazardous area: spring terminals, blue, Non-hazardous area: Yokogawa system connector, 40-pin, Number of modules: 16, Signal type: Analog input/analog output, Manufacturer: Yokogawa, Control system type: CENTUM VP

Specifications

Supply

Order code (Pepperl+Fuchs part number)70101322
ConnectionX20: terminals 3, 5(+); 4, 6(-)
Nominal voltage24 V DC , in consideration of rated voltage of used isolators
Voltage drop0.9 V , voltage drop across the series diode on the termination board must be considered
Ripple≤ 10 %
Fusing4 A , in each case for 16 modules
Power dissipation≤ 500 mW , without modules
Reverse polarity protectionyes
LifecycleActive (current Pepperl+Fuchs product)

Redundancy

SupplyRedundancy available. The supply for the isolators is decoupled, monitored and fused.

Fault indication output

ConnectionX20: terminals 1, 2
Output typevolt-free contact
Switch behaviourno fault: relay contact closed power supply fault: relay contact open module fault: relay contact open
Contact loading30 V DC , 1 A

Indicators/settings

Display elementsLEDs PWR ON (Termination Board power supply) - LED power supply I, green LED - LED power supply II, green LED LED FAULT (fault indication), red LED - LED lits: module fault - LED flashes: power supply fault

Directive conformity

Electromagnetic compatibility: Directive 2014/30/EUEN 61326-1:2013 (industrial locations)

Conformity

Electromagnetic compatibilityNE 21:2017 For further information see system description.
Degree of protectionIEC 60529:2001

Ambient conditions

Ambient temperature-20 ... 60 °C (-4 ... 140 °F)
Storage temperature-40 ... 70 °C (-40 ... 158 °F)

Mechanical specifications

Degree of protectionIP20
Connection: Field sideexplosion hazardous area: spring terminals , blue
Connection: Control sidenon-explosion hazardous area: Yokogawa system connector, 40-pin
Connection: Supplypluggable screw terminals , black
Connection: Fault outputpluggable screw terminals , black
Core cross sectionspring terminals: rigid: 0.2 ... 2.5 mm2 flexible: 0.25 ... 1.5 mm2
Materialhousing: polycarbonate
Massapprox. 645 g
Dimensions240 x 175 x 153 mm (9.45 x 6.9 x 6.02 inch) (W x H x D) , depth including module assembly
Height175 mm
Width240 mm
Depth153 mm
Mountingon 35 mm DIN mounting rail acc. to EN 60715:2001

Data for application in connection with hazardous areas

EU-type examination certificateCESI 06 ATEX 022
MarkingII (1)G [Ex ia Ga] IIC [exsign] II (1)D [Ex ia Da] IIIC [exsign] I (M1) [Ex ia Ma] I
Non-hazardous area: Maximum safe voltage250 V (Attention! Um is no rated voltage.)
Galvanic isolation: Field circuit/control circuitsafe electrical isolation acc. to IEC/EN 60079-11, voltage peak value 375 V
Directive conformity: Directive 2014/34/EUEN IEC 60079-0:2018+AC:2020 , EN 60079-11:2012 , EN 50303:2000

International approvals

IECEx approval: IECEx certificateIECEx CES 06.0003
IECEx approval: IECEx marking[Ex ia Ga] IIC [Ex ia Da] IIIC [Ex ia Ma] I

General information

Supplementary informationObserve the certificates, declarations of conformity, instruction manuals, and manuals where applicable. For information see www.pepperl-fuchs.com.

HiCTB16-YC3-RRB-KS-CC-AM16-Y2: frequently asked questions

When can HiCTB16-YC3-RRB-KS-CC-AM16-Y2 be shipped?

HiCTB16-YC3-RRB-KS-CC-AM16-Y2 is sourced on request — request a quote and we'll confirm the exact availability and shipping timeline for this specific unit.

Can I pick up HiCTB16-YC3-RRB-KS-CC-AM16-Y2 in person?

Local pickup from our Groningen, Netherlands warehouse may be possible — contact us before ordering to check availability and arrange a collection time.

Is express delivery available?

Yes — mention it when you request a quote for HiCTB16-YC3-RRB-KS-CC-AM16-Y2 and we'll include express shipping options in our reply.

My factory is down and I need this urgently — can you help?

For a critical breakdown, contact us directly at +31 (0)50-7110348 or sales@partnerplc.com — we can look into same-day courier or dedicated taxi/hotshot delivery for HiCTB16-YC3-RRB-KS-CC-AM16-Y2, subject to availability and destination.

More Pepperl Fuchs parts

Pepperl Fuchs HiCTB16-YC3-RRB-KS-CC-AM16-Y2Price and lead time confirmed within 1 business day
Request a Quote