Pepperl Fuchs HiCTB16-TRX-RAC-PL-AI16 – Termination Board. System board for Schneider Electric
Request a Quote
Quick facts
| Availability | Confirmed on request |
| Category | H-System (Termination Board Mounting) |
| Lifecycle | active |
| Warranty | 12-month (new) · 3-month (used/refurbished) |
Shipping & availability
When can HiCTB16-TRX-RAC-PL-AI16 be shipped?
HiCTB16-TRX-RAC-PL-AI16 is sourced on request — request a quote and we'll confirm the exact availability and shipping timeline for this specific unit.
Can I pick up HiCTB16-TRX-RAC-PL-AI16 in person?
Local pickup from our Groningen, Netherlands warehouse may be possible — contact us before ordering to check availability and arrange a collection time.
Is express delivery available?
Yes — mention it when you request a quote for HiCTB16-TRX-RAC-PL-AI16 and we'll include express shipping options in our reply.
My factory is down and I need this urgently — can you help?
For a critical breakdown, contact us directly at +31 (0)50-7110348 or sales@partnerplc.com — we can look into same-day courier or dedicated taxi/hotshot delivery for HiCTB16-TRX-RAC-PL-AI16, subject to availability and destination.
Termination Board. System board for Schneider Electric, Tricon CX series by Triconex, TAN48 approval, For 32-channel (16+16) AI cards 3722X and 3723X, For 16 modules, Recommended modules: HiC2025(A) (AI), HiC2025ES (AI), HiC2081 (TI), 24 V DC supply, Hazardous area: pluggable screw terminals, blue, Non-hazardous area: ELCO socket, 56-pin, Number of modules: 16, Signal type: Analog input, Manufacturer: Triconex, Control system type: Tricon CX. Connection: X20: terminals 3, 5(+); 4, 6(-). Nominal voltage: 24 V DC , in consideration of rated voltage of used isolators. Voltage drop: 0.9 V , voltage drop across the series diode on the termination board must be considered. Ripple: ≤ 10 %. Fusing: 4 A , in each case for 16 modules. Power dissipation: ≤ 500 mW , without modules. Reverse polarity protection: yes. Supply: Redundancy available. The supply for the isolators is decoupled, monitored and fused.. Connection: X20: terminals 1(+), 2(-). Output type: volt-free transistor output , not short-circuit protected , not overload protected. Rated voltage: 30 V DC. Rated current: 100 mA. Signal level: no fault: (external voltage) - 1 V max. for 100 mA (Tamb = 25 °C (77 °F))power supply fault/module fault: blocked output (off-state current ≤ 10 µA). Display elements: LED PWR1 (termination board power supply), green LEDLED PWR2 (termination board power supply), green LED. Electromagnetic compatibility: . Directive 2014/30/EUEN 61326-1:2013 (industrial locations): . Directive 2014/30/EU: EN 61326-1:2013 (industrial locations). Electromagnetic compatibility: NE 21:2017For further information see system description.. Degree of protection: IEC 60529:2001. Ambient temperature: -20 ... 60 °C (-4 ... 140 °F). Storage temperature: -40 ... 85 °C (-40 ... 185 °F). Degree of protection: IP20. Connection: . Field sideexplosion hazardous area: pluggable screw terminals , blueControl sidenon-explosion hazardous area: ELCO socket, 56-pinSupplypluggable screw terminals , blackFault outputpluggable screw terminals , black: . Field side: explosion hazardous area: pluggable screw terminals , blue. Control side: non-explosion hazardous area: ELCO socket, 56-pin. Supply: pluggable screw terminals , black. Fault output: pluggable screw terminals , black. Core cross section: screw terminals 0.25 ... 2.5 mm2 (24 ... 12 AWG). Material: housing: polycarbonate, 10 % glass fiber reinforced. Mass: approx. 775 g. Dimensions: 216 x 200 x 163 mm (8.5 x 7.9 x 6.42 inch) (W x H x D) , depth including module assembly. Height200 mmWidth216 mmDepth163 mm: . Height: 200 mm. Width: 216 mm. Depth: 163 mm. Mounting: on 35 mm DIN mounting rail acc. to EN 60715:2001. EU-type examination certificate: CESI 06 ATEX 022. Marking II (1)G [Ex ia Ga] IIC [exsign] II (1)D [Ex ia Da] IIIC [exsign] I (M1) [Ex ia Ma] I: . Marking: II (1)G [Ex ia Ga] IIC [exsign] II (1)D [Ex ia Da] IIIC [exsign] I (M1) [Ex ia Ma] I. Non-hazardous area: . Maximum safe voltage250 V (Attention! Um is no rated voltage.): . Maximum safe voltage: 250 V (Attention! Um is no rated voltage.). Galvanic isolation: . Field circuit/control circuitsafe electrical isolation acc. to IEC/EN 60079-11, voltage peak value 375 V: . Field circuit/control circuit: safe electrical isolation acc. to IEC/EN 60079-11, voltage peak value 375 V. Directive conformity: . Directive 2014/34/EUEN IEC 60079-0:2018+AC:2020 , EN 60079-11:2012 , EN 50303:2000: . Directive 2014/34/EU: EN IEC 60079-0:2018+AC:2020 , EN 60079-11:2012 , EN 50303:2000. UL approval: E106378. Control drawing116-0327: . Control drawing: 116-0327. IECEx approval: . IECEx certificateIECEx CES 06.0003IECEx marking[Ex ia Ga] IIC [Ex ia Da] IIIC [Ex ia Ma] I: . IECEx certificate: IECEx CES 06.0003. IECEx marking: [Ex ia Ga] IIC [Ex ia Da] IIIC [Ex ia Ma] I. Supplementary information: Observe the certificates, declarations of conformity, instruction manuals, and manuals where applicable. For information see www.pepperl-fuchs.com.
Specifications
Supply
| Connection | X20: terminals 3, 5(+); 4, 6(-) |
| Nominal voltage | 24 V DC , in consideration of rated voltage of used isolators |
| Voltage drop | 0.9 V , voltage drop across the series diode on the termination board must be considered |
| Ripple | ≤ 10 % |
| Fusing | 4 A , in each case for 16 modules |
| Power dissipation | ≤ 500 mW , without modules |
| Reverse polarity protection | yes |
Redundancy
| Supply | Redundancy available. The supply for the isolators is decoupled, monitored and fused. |
Fault indication output
| Connection | X20: terminals 1(+), 2(-) |
| Output type | volt-free transistor output , not short-circuit protected , not overload protected |
| Rated voltage | 30 V DC Ur |
| Rated current | 100 mA Ir |
| Signal level | no fault: (external voltage) - 1 V max. for 100 mA (Tamb = 25 °C (77 °F))power supply fault/module fault: blocked output (off-state current ≤ 10 µA) |
Indicators/settings
| Display elements | LED PWR1 (termination board power supply), green LEDLED PWR2 (termination board power supply), green LED |
Directive conformity
| Electromagnetic compatibility | |
| Directive 2014/30/EUEN 61326-1:2013 (industrial locations) | Directive 2014/30/EU |
| Directive 2014/30/EU | EN 61326-1:2013 (industrial locations) |
Conformity
| Electromagnetic compatibility | NE 21:2017For further information see system description. |
| Degree of protection | IEC 60529:2001 |
Ambient conditions
| Ambient temperature | -20 ... 60 °C (-4 ... 140 °F) |
| Storage temperature | -40 ... 85 °C (-40 ... 185 °F) |
Mechanical specifications
| Degree of protection | IP20 |
| Connection | |
| Field sideexplosion hazardous area: pluggable screw terminals , blueControl sidenon-explosion hazardous area: ELCO socket, 56-pinSupplypluggable screw terminals , blackFault outputpluggable screw terminals , black | Field side |
| Field side | explosion hazardous area: pluggable screw terminals , blue |
| Control side | non-explosion hazardous area: ELCO socket, 56-pin |
| Supply | pluggable screw terminals , black |
| Fault output | pluggable screw terminals , black |
| Core cross section | screw terminals 0.25 ... 2.5 mm2 (24 ... 12 AWG) |
| Material | housing: polycarbonate, 10 % glass fiber reinforced |
| Mass | approx. 775 g |
| Dimensions | 216 x 200 x 163 mm (8.5 x 7.9 x 6.42 inch) (W x H x D) , depth including module assembly |
| Height200 mmWidth216 mmDepth163 mm | Height |
| Height | 200 mm |
| Width | 216 mm |
| Depth | 163 mm |
| Mounting | on 35 mm DIN mounting rail acc. to EN 60715:2001 |
Data for application in connection with hazardous areas
| EU-type examination certificate | CESI 06 ATEX 022 |
| Marking II (1)G [Ex ia Ga] IIC [exsign] II (1)D [Ex ia Da] IIIC [exsign] I (M1) [Ex ia Ma] I | Marking |
| Marking | II (1)G [Ex ia Ga] IIC [exsign] II (1)D [Ex ia Da] IIIC [exsign] I (M1) [Ex ia Ma] I |
| Non-hazardous area | |
| Maximum safe voltage250 V (Attention! Um is no rated voltage.) | Maximum safe voltage |
| Maximum safe voltage | 250 V (Attention! Um is no rated voltage.) |
| Galvanic isolation | |
| Field circuit/control circuitsafe electrical isolation acc. to IEC/EN 60079-11, voltage peak value 375 V | Field circuit/control circuit |
| Field circuit/control circuit | safe electrical isolation acc. to IEC/EN 60079-11, voltage peak value 375 V |
| Directive conformity | |
| Directive 2014/34/EUEN IEC 60079-0:2018+AC:2020 , EN 60079-11:2012 , EN 50303:2000 | Directive 2014/34/EU |
| Directive 2014/34/EU | EN IEC 60079-0:2018+AC:2020 , EN 60079-11:2012 , EN 50303:2000 |
International approvals
| UL approval | E106378 |
| Control drawing116-0327 | Control drawing |
| Control drawing | 116-0327 |
| IECEx approval | |
| IECEx certificateIECEx CES 06.0003IECEx marking[Ex ia Ga] IIC [Ex ia Da] IIIC [Ex ia Ma] I | IECEx certificate |
| IECEx certificate | IECEx CES 06.0003 |
| IECEx marking | [Ex ia Ga] IIC [Ex ia Da] IIIC [Ex ia Ma] I |
General information
| Supplementary information | Observe the certificates, declarations of conformity, instruction manuals, and manuals where applicable. For information see www.pepperl-fuchs.com. |
More Pepperl Fuchs parts
Available on requestPepperl Fuchs HiCTB16-TRI-DIISD-EL-PL – Termination Board. System board for Schneider Electric
Available on requestPepperl Fuchs HiCTB16-TRI-DIISS-EL-PL – Termination Board. System board for Schneider Electric
Available on requestPepperl Fuchs HiCTB16-TRI-DIISS-EL-PL-Y1 – Termination Board. System board for Schneider Electric
Available on requestPepperl Fuchs HiCTB16-TRI-DOISS-EL-PL-Y1 – Termination Board. System board for Schneider Electric
Available on requestPepperl Fuchs HiCTB16-TRX-RAC-PL-DI16 – Termination Board. System board for Schneider Electric
Available on requestPepperl Fuchs HiCTB16-TRX-RAC-PL-DI32 – Termination Board. System board for Schneider Electric
Available on requestPepperl Fuchs HiCTB16-TRX-RAC-PL-DO16 – Termination Board. System board for Schneider Electric
Available on requestPepperl Fuchs HiCTB16-TRX-RAC-PL-IO16 – Termination Board. System board for Schneider Electric