Pepperl Fuchs HiC2441
Request a Quote
Quick facts
| Availability | Confirmed on request |
| Category | H-System (Termination Board Mounting) |
| Lifecycle | active |
| Warranty | 12-month (new) · 3-month (used/refurbished) |
Shipping & availability
When can HiC2441 be shipped?
HiC2441 is sourced on request — request a quote and we'll confirm the exact availability and shipping timeline for this specific unit.
Can I pick up HiC2441 in person?
Local pickup from our Groningen, Netherlands warehouse may be possible — contact us before ordering to check availability and arrange a collection time.
Is express delivery available?
Yes — mention it when you request a quote for HiC2441 and we'll include express shipping options in our reply.
My factory is down and I need this urgently — can you help?
For a critical breakdown, contact us directly at +31 (0)50-7110348 or sales@partnerplc.com — we can look into same-day courier or dedicated taxi/hotshot delivery for HiC2441, subject to availability and destination.
SMART Universal Barrier. 1-channel isolated barrier, 24 V DC supply (bus powered), Analog input, digital input,<br>analog output, digital output, No configuration required, device is self-adapting, HART transparency, Low power dissipation, 3-way isolation, Up to SIL 2 acc. to IEC/EN 61508. Signal type: Universal. Safety Integrity Level (SIL): SIL 2. Systematic capability (SC): SC 2. Connection: SL1: 1a, 1b(-); 2a, 2b(+). Rated voltage: 19 ... 30 V DC bus powered via Termination Board. Ripple: ≤ 10 %. Rated current: ≤ 30 mA. Power consumption: ≤ 700 mW. Suitable field devices: 2-wire SMART transmitters, current sources. Signal: 0/4 ... 20 mA , limited to approx. 40 mA (depends on control system) , reverse polarity protected. Field circuit: SL2: 5a(+), 5b(-) (2-wire SMART transmitter)SL2: 5a(+), 1b(-) (2-wire SMART transmitter with current source). Voltage drop: approx. 4 V (current source). Control circuit: SL1: 8a(+), 7a(-). Supply voltage: min. 16 V at 20 mA (2-wire SMART transmitter). Voltage: 15 ... 30 V. Signal: 0/4 ... 20 mA , sink mode , working voltage 15 ... 30 V. Ripple: 20 mV rms. Suitable field devices: I/P converters (positioner), on-site-displays. Signal: 0/4 ... 20 mA. Field circuit: SL2: 5a(+), 5b(-). Load: 0 ... 650 Ω. Voltage: ≥ 13 V at 20 mA. Ripple: 20 mV rms. Control circuit: SL1: 8a(+), 7a(-). Voltage: 12 ... 30 V. Signal: 0/4 ... 20 mA. Line fault detection: > 100 kΩ at max. 30 V, with field wiring open. Field circuit: SL2: 5a(+), 1a(-) (NAMUR sensor)SL2: 5a(+), 5b(-) (dry contact). Suitable field devices: NAMUR sensors according to IEC/EN 60947-5-6, dry contacts. Signal: 0.1 ... 9 mA , sink mode. Open loop voltage: approx. 10 V DC , 1 kΩ series resistance. Signal: 0.1 ... 9 mA. Control circuit: SL1: 8a(+), 7a(-). Voltage: 13 ... 30 V. Field circuit: SL2: 5a(+), 5b(-). Suitable field devices: Solenoid Valve , audible alarm , visual alarm. Drive capability: 12 V / 40 mA at 300 Ω load. Internal resistor: min. 240 Ω. Current: 40 mA. Voltage: 12 V. Current limit: 45 mA. Open loop voltage: approx. 22 V. Control circuit: SL1: 8a(+), 7a(-). Voltage: 1-signal: 19 ... 30 V DC 0-signal: 0 ... 5 V DC. Current: 1-signal: 0 ... 45 mA, depending on the output load 0-signal: < 0.1 mA, independent of the output load. Power dissipation: 1.1 W at 24 V, 300 Ω load (digital output). Deviation: at 20 °C (68 °F) ≤ ±20 µA incl. linearity, hysteresis and supply fluctuations at 4 ... 20 mA (analog input, analog output) ≤ ±60 µA incl. linearity, hysteresis and supply fluctuations at 0 ... 45 mA (digital output). Influence of ambient temperature< 2 µA/K (0 ... 70 °C (32 ... 158 °F)) < 3 µA/K (-40 ... 0 °C (-40 ... 32 °F)): . Influence of ambient temperature: < 2 µA/K (0 ... 70 °C (32 ... 158 °F)) < 3 µA/K (-40 ... 0 °C (-40 ... 32 °F)). Switching frequency: ≤ 500 Hz with 50 % duty cycle (digital input, NAMUR sensor) ≤ 5 Hz (digital input, dry contact) ≤ 20 Hz (digital output). Frequency range: HART: bandwidth by 0.5 Vpp signal and/or 1 mApp signal 950 ... 2500 Hz (analog input, analog output). Settling time: ≤ 20 ms (analog input, analog output) ≤ 1 ms (digital input, NAMUR sensor). Reaction time: ≤ 5 ms , turn-on/turn-off time (digital output). Control/power supply: basic insulation according to IEC/EN 61010-1, rated insulation voltage 60 Veff. Display elements: LED. Labeling: space for labeling at the front. Electromagnetic compatibility: . Directive 2014/30/EUEN 61326-1:2013 (industrial locations): . Directive 2014/30/EU: EN 61326-1:2013 (industrial locations). Electromagnetic compatibility: NE 21:2012For further information see system description.. Degree of protection: IEC 60529:2001. Protection against electrical shock: IEC 61010-1:2010. Input: EN 60947-5-6:2000. Ambient temperature: -40 ... 70 °C (-40 ... 158 °F) Observe the temperature range limited by derating, see section derating.. Storage temperature: -40 ... 85 °C (-40 ... 185 °F). Relative humidity: 95 % non-condensing. Degree of protection: IP20. Mass: approx. 105 g. Dimensions: 12.5 x 106 x 128 mm (0.5 x 4.2 x 5.1 inch) (W x H x D). Height106 mmWidth12.5 mmDepth128 mm: . Height: 106 mm. Width: 12.5 mm. Depth: 128 mm. Mounting: on termination board. Coding: pin 1 and 4 trimmed For further information see system description.. EU-type examination certificate: TÜV 14 ATEX 153522 X. Marking II (1)G [Ex ia Ga] IIC [exsign] II (1)D [Ex ia Da] IIIC [exsign] I (M1) [Ex ia Ma] I: . Marking: II (1)G [Ex ia Ga] IIC [exsign] II (1)D [Ex ia Da] IIIC [exsign] I (M1) [Ex ia Ma] I. Supply: . Maximum safe voltageUm250 V (Attention! The rated voltage can be lower.): Um. Maximum safe voltage: 250 V (Attention! The rated voltage can be lower.). Equipment: SL2: 5a(+), 5b(-). VoltageUo25.2 VCurrentIo110 mAPowerPo693 mWInternal capacitanceCi5.7 nFInternal inductanceLi0 mH: Uo. Voltage: 25.2 V. Current: 110 mA. Power: 693 mW. Internal capacitance: 5.7 nF. Internal inductance: 0 mH. Equipment: SL2: 5a(+), 1b(-). VoltageUi< 28 VCurrentIi< 115 mAVoltageUo7.2 VCurrentIo0 mAPowerPo0 mWInternal capacitanceCi5.7 nFInternal inductanceLi0 mH: Ui. Voltage: < 28 V. Current: < 115 mA. Voltage: 7.2 V. Current: 0 mA. Power: 0 mW. Internal capacitance: 5.7 nF. Internal inductance: 0 mH. Equipment: SL2: 5a(+), 1a(-). VoltageUo12.6 VCurrentIo13 mAPowerPo41 mWInternal capacitanceCi5.7 nFInternal inductanceLi0 mH: Uo. Voltage: 12.6 V. Current: 13 mA. Power: 41 mW. Internal capacitance: 5.7 nF. Internal inductance: 0 mH. Certificate: TÜV 14 ATEX 153523 X. Marking II 3G Ex ec IIC T4 Gc: . Marking: II 3G Ex ec IIC T4 Gc. Galvanic isolation: . Input/Other circuitssafe electrical isolation acc. to IEC/EN 60079-11, voltage peak value 375 V: . Input/Other circuits: safe electrical isolation acc. to IEC/EN 60079-11, voltage peak value 375 V. Directive conformity: . Directive 2014/34/EUEN IEC 60079-0:2018+AC:2020 , EN 60079-11:2012 , EN 60079-7:2015+A1:2018: . Directive 2014/34/EU: EN IEC 60079-0:2018+AC:2020 , EN 60079-11:2012 , EN 60079-7:2015+A1:2018. UL approval: E106378. Control drawing116-0408 (cULus): . Control drawing: 116-0408 (cULus). IECEx approval: . IECEx certificateIECEx TUN 15.0004XIECEx marking[Ex ia Ga] IIC , [Ex ia Da] IIIC , [Ex ia Ma] I Ex ec IIC T4 Gc: . IECEx certificate: IECEx TUN 15.0004X. IECEx marking: [Ex ia Ga] IIC , [Ex ia Da] IIIC , [Ex ia Ma] I Ex ec IIC T4 Gc. Supplementary information: Observe the certificates, declarations of conformity, instruction manuals, and manuals where applicable. For information see www.pepperl-fuchs.com.
Specifications
General specifications
| Signal type | Universal |
Functional safety related parameters
| Safety Integrity Level (SIL) | SIL 2 |
| Systematic capability (SC) | SC 2 |
Supply
| Connection | SL1: 1a, 1b(-); 2a, 2b(+) |
| Rated voltage | 19 ... 30 V DC bus powered via Termination Board Ur |
| Ripple | ≤ 10 % |
| Rated current | ≤ 30 mA Ir |
| Power consumption | ≤ 700 mW |
Analog input
| Suitable field devices | 2-wire SMART transmitters, current sources |
| Signal | 0/4 ... 20 mA , limited to approx. 40 mA (depends on control system) , reverse polarity protected |
| Field circuit | SL2: 5a(+), 5b(-) (2-wire SMART transmitter)SL2: 5a(+), 1b(-) (2-wire SMART transmitter with current source) |
| Voltage drop | approx. 4 V (current source) |
| Control circuit | SL1: 8a(+), 7a(-) |
| Supply voltage | min. 16 V at 20 mA (2-wire SMART transmitter) |
| Voltage | 15 ... 30 V |
| Signal | 0/4 ... 20 mA , sink mode , working voltage 15 ... 30 V |
| Ripple | 20 mV rms |
Analog output
| Suitable field devices | I/P converters (positioner), on-site-displays |
| Signal | 0/4 ... 20 mA |
| Field circuit | SL2: 5a(+), 5b(-) |
| Load | 0 ... 650 Ω |
| Voltage | ≥ 13 V at 20 mA |
| Ripple | 20 mV rms |
| Control circuit | SL1: 8a(+), 7a(-) |
| Voltage | 12 ... 30 V |
| Signal | 0/4 ... 20 mA |
| Line fault detection | > 100 kΩ at max. 30 V, with field wiring open |
Digital input
| Field circuit | SL2: 5a(+), 1a(-) (NAMUR sensor)SL2: 5a(+), 5b(-) (dry contact) |
| Suitable field devices | NAMUR sensors according to IEC/EN 60947-5-6, dry contacts |
| Signal | 0.1 ... 9 mA , sink mode |
| Open loop voltage | approx. 10 V DC , 1 kΩ series resistance |
| Signal | 0.1 ... 9 mA |
| Control circuit | SL1: 8a(+), 7a(-) |
| Voltage | 13 ... 30 V |
Digital output
| Field circuit | SL2: 5a(+), 5b(-) |
| Suitable field devices | Solenoid Valve , audible alarm , visual alarm |
| Drive capability | 12 V / 40 mA at 300 Ω load |
| Internal resistor | min. 240 Ω Ri |
| Current | 40 mA Ie |
| Voltage | 12 V Ue |
| Current limit | 45 mA Imax |
| Open loop voltage | approx. 22 V Us |
| Control circuit | SL1: 8a(+), 7a(-) |
| Voltage | 1-signal: 19 ... 30 V DC 0-signal: 0 ... 5 V DC |
| Current | 1-signal: 0 ... 45 mA, depending on the output load 0-signal: < 0.1 mA, independent of the output load |
| Power dissipation | 1.1 W at 24 V, 300 Ω load (digital output) |
Transfer characteristics
| Deviation | at 20 °C (68 °F) ≤ ±20 µA incl. linearity, hysteresis and supply fluctuations at 4 ... 20 mA (analog input, analog output) ≤ ±60 µA incl. linearity, hysteresis and supply fluctuations at 0 ... 45 mA (digital output) |
| Influence of ambient temperature< 2 µA/K (0 ... 70 °C (32 ... 158 °F)) < 3 µA/K (-40 ... 0 °C (-40 ... 32 °F)) | Influence of ambient temperature |
| Influence of ambient temperature | < 2 µA/K (0 ... 70 °C (32 ... 158 °F)) < 3 µA/K (-40 ... 0 °C (-40 ... 32 °F)) |
| Switching frequency | ≤ 500 Hz with 50 % duty cycle (digital input, NAMUR sensor) ≤ 5 Hz (digital input, dry contact) ≤ 20 Hz (digital output) |
| Frequency range | HART: bandwidth by 0.5 Vpp signal and/or 1 mApp signal 950 ... 2500 Hz (analog input, analog output) |
| Settling time | ≤ 20 ms (analog input, analog output) ≤ 1 ms (digital input, NAMUR sensor) |
| Reaction time | ≤ 5 ms , turn-on/turn-off time (digital output) |
Galvanic isolation
| Control/power supply | basic insulation according to IEC/EN 61010-1, rated insulation voltage 60 Veff |
Indicators/settings
| Display elements | LED |
| Labeling | space for labeling at the front |
Directive conformity
| Electromagnetic compatibility | |
| Directive 2014/30/EUEN 61326-1:2013 (industrial locations) | Directive 2014/30/EU |
| Directive 2014/30/EU | EN 61326-1:2013 (industrial locations) |
Conformity
| Electromagnetic compatibility | NE 21:2012For further information see system description. |
| Degree of protection | IEC 60529:2001 |
| Protection against electrical shock | IEC 61010-1:2010 |
| Input | EN 60947-5-6:2000 |
Ambient conditions
| Ambient temperature | -40 ... 70 °C (-40 ... 158 °F) Observe the temperature range limited by derating, see section derating. |
| Storage temperature | -40 ... 85 °C (-40 ... 185 °F) |
| Relative humidity | 95 % non-condensing |
Mechanical specifications
| Degree of protection | IP20 |
| Mass | approx. 105 g |
| Dimensions | 12.5 x 106 x 128 mm (0.5 x 4.2 x 5.1 inch) (W x H x D) |
| Height106 mmWidth12.5 mmDepth128 mm | Height |
| Height | 106 mm |
| Width | 12.5 mm |
| Depth | 128 mm |
| Mounting | on termination board |
| Coding | pin 1 and 4 trimmed For further information see system description. |
Data for application in connection with hazardous areas
| EU-type examination certificate | TÜV 14 ATEX 153522 X |
| Marking II (1)G [Ex ia Ga] IIC [exsign] II (1)D [Ex ia Da] IIIC [exsign] I (M1) [Ex ia Ma] I | Marking |
| Marking | II (1)G [Ex ia Ga] IIC [exsign] II (1)D [Ex ia Da] IIIC [exsign] I (M1) [Ex ia Ma] I |
| Supply | |
| Maximum safe voltageUm250 V (Attention! The rated voltage can be lower.) | Um Maximum safe voltage |
| Maximum safe voltage | 250 V (Attention! The rated voltage can be lower.) Um |
| Equipment | SL2: 5a(+), 5b(-) |
| VoltageUo25.2 VCurrentIo110 mAPowerPo693 mWInternal capacitanceCi5.7 nFInternal inductanceLi0 mH | Uo Voltage |
| Voltage | 25.2 V Uo |
| Current | 110 mA Io |
| Power | 693 mW Po |
| Internal capacitance | 5.7 nF Ci |
| Internal inductance | 0 mH Li |
| Equipment | SL2: 5a(+), 1b(-) |
| VoltageUi< 28 VCurrentIi< 115 mAVoltageUo7.2 VCurrentIo0 mAPowerPo0 mWInternal capacitanceCi5.7 nFInternal inductanceLi0 mH | Ui Voltage |
| Voltage | < 28 V Ui |
| Current | < 115 mA Ii |
| Voltage | 7.2 V Uo |
| Current | 0 mA Io |
| Power | 0 mW Po |
| Internal capacitance | 5.7 nF Ci |
| Internal inductance | 0 mH Li |
| Equipment | SL2: 5a(+), 1a(-) |
| VoltageUo12.6 VCurrentIo13 mAPowerPo41 mWInternal capacitanceCi5.7 nFInternal inductanceLi0 mH | Uo Voltage |
| Voltage | 12.6 V Uo |
| Current | 13 mA Io |
| Power | 41 mW Po |
| Internal capacitance | 5.7 nF Ci |
| Internal inductance | 0 mH Li |
| Certificate | TÜV 14 ATEX 153523 X |
| Marking II 3G Ex ec IIC T4 Gc | Marking |
| Marking | II 3G Ex ec IIC T4 Gc |
| Galvanic isolation | |
| Input/Other circuitssafe electrical isolation acc. to IEC/EN 60079-11, voltage peak value 375 V | Input/Other circuits |
| Input/Other circuits | safe electrical isolation acc. to IEC/EN 60079-11, voltage peak value 375 V |
| Directive conformity | |
| Directive 2014/34/EUEN IEC 60079-0:2018+AC:2020 , EN 60079-11:2012 , EN 60079-7:2015+A1:2018 | Directive 2014/34/EU |
| Directive 2014/34/EU | EN IEC 60079-0:2018+AC:2020 , EN 60079-11:2012 , EN 60079-7:2015+A1:2018 |
International approvals
| UL approval | E106378 |
| Control drawing116-0408 (cULus) | Control drawing |
| Control drawing | 116-0408 (cULus) |
| IECEx approval | |
| IECEx certificateIECEx TUN 15.0004XIECEx marking[Ex ia Ga] IIC , [Ex ia Da] IIIC , [Ex ia Ma] I Ex ec IIC T4 Gc | IECEx certificate |
| IECEx certificate | IECEx TUN 15.0004X |
| IECEx marking | [Ex ia Ga] IIC , [Ex ia Da] IIIC , [Ex ia Ma] I Ex ec IIC T4 Gc |
General information
| Supplementary information | Observe the certificates, declarations of conformity, instruction manuals, and manuals where applicable. For information see www.pepperl-fuchs.com. |