IFM TK6130
Request a Quote
Quick facts
| Availability | Confirmed on request |
| Category | Intuitive switch point setting |
| Warranty | 12-month (new) · 3-month (used/refurbished) |
Shipping & availability
When can TK6130 be shipped?
TK6130 is sourced on request — request a quote and we'll confirm the exact availability and shipping timeline for this specific unit.
Can I pick up TK6130 in person?
Local pickup from our Groningen, Netherlands warehouse may be possible — contact us before ordering to check availability and arrange a collection time.
Is express delivery available?
Yes — mention it when you request a quote for TK6130 and we'll include express shipping options in our reply.
My factory is down and I need this urgently — can you help?
For a critical breakdown, contact us directly at +31 (0)50-7110348 or sales@partnerplc.com — we can look into same-day courier or dedicated taxi/hotshot delivery for TK6130, subject to availability and destination.
Simple switch point setting by means of two setting rings allowing optimum reading Setting of the switch points without system temperature being applied Two complementary switching outputs with adjustable hysteresis Particularly good response dynamics and very short power-on delay time Mechanical locking prevents inadvertent switch point manipulation
Specifications
Product characteristics
| Number of inputs and outputs | Number of digital outputs: 2 |
| Measuring range | -25...140 °C; -13...284 °F |
| -25...140 °C | -13...284 °F |
| Process connection | threaded connection G 1/4 external thread |
| Installation length EL[mm] [mm] | 39 |
Application
| Special feature | Gold-plated contacts |
| Measuring element | 1 x Pt 1000; (to DIN EN 60751, class B) |
| Media | liquids and gases |
| Medium temperature[°C] [°C] | -25...125; (145 max. 1 h) |
| Pressure rating | 300 bar; 30 MPa |
| 300 bar | 30 MPa |
| Minimum installation depth[mm] [mm] | 15 |
Electrical data
| Operating voltage[V] [V] | 9.6...32 DC; ("supply class 2" to cULus) |
| Current consumption[mA] [mA] | < 30 |
| Protection class | III |
| Reverse polarity protection | yes |
| Power-on delay time[s] [s] | 0.5 |
Inputs / outputs
| Number of inputs and outputs | Number of digital outputs: 2 |
Outputs
| Total number of outputs | 2 |
| Output signal | switching signal |
| Electrical design | PNP |
| Number of digital outputs | 2 |
| Output function | complementary |
| Max. voltage drop switching output DC[V] [V] | 2 |
| Permanent current rating of switching output DC[mA] [mA] | 500 |
| Short-circuit protection | yes |
| Type of short-circuit protection | pulsed |
| Overload protection | yes |
Measuring/setting range
| Probe length L[mm] [mm] | 25 |
| Measuring range | -25...140 °C; -13...284 °F |
| -25...140 °C | -13...284 °F |
| Set point SP | -16...140 °C; 3...284 °F |
| -16...140 °C | 3...284 °F |
| Reset point rP | -20...136 °C; -4...277 °F |
| -20...136 °C | -4...277 °F |
Accuracy / deviations
| Temperature drift per 10 K[K] [K] | 0.1 |
| Repeatability[K] [K] | ± 0,1 |
| Setting accuracy[K] [K] | ± 3 |
Response times
| Dynamic response T05 / T09[s] [s] | 1 / 3; (to DIN EN 60751) |
Software / programming
| Adjustment of the switch point | setting rings |
Operating conditions
| Ambient temperature[°C] [°C] | -25...70 |
| Storage temperature[°C] [°C] | -40...100 |
| Protection | IP 67 |
Tests / approvals
| EMC | DIN EN 61000-4-2 ESD; 4 kV CD / 8 kV AD; EN 61000-4-3 HF radiated; 10 V/m; DIN EN 61000-4-4 Burst; 2 kV; EN 61000-4-6 HF conducted; 10 V |
| DIN EN 61000-4-2 ESD | 4 kV CD / 8 kV AD |
| EN 61000-4-3 HF radiated | 10 V/m |
| DIN EN 61000-4-4 Burst | 2 kV |
| EN 61000-4-6 HF conducted | 10 V |
| Shock resistance | DIN IEC 68-2-27; 50 g (11 ms) |
| DIN IEC 68-2-27 | 50 g (11 ms) |
| Vibration resistance | DIN EN 60068-2-6; 20 g (10...2000 Hz) |
| DIN EN 60068-2-6 | 20 g (10...2000 Hz) |
| MTTF[years] [years] | 684 |
Mechanical data
| Weight[g] [g] | 102.5 |
| Housing | cylindrical |
| Dimensions[mm] [mm] | Ø 27 / L = 96.5 |
| Materials | stainless steel (316L/1.4404); PC; PBT; FKM |
| Materials (wetted parts) | stainless steel (316L/1.4404); FKM |
| Tightening torque[Nm] [Nm] | 35 |
| Process connection | threaded connection G 1/4 external thread |
| Probe diameter[mm] [mm] | 8.2 |
| Installation length EL[mm] [mm] | 39 |
Displays / operating elements
| Display | operation; LED, green; switching status; LED, yellow |
| operation | LED, green |
| switching status | LED, yellow |
| With scale | yes |
Remarks
| Remarks | The values for accuracy apply to flowing water. |
| Pack quantity | 1 pcs. |
Electrical connection
| Connector | 1 x M12; coding: A; Contacts: gold-plated |