IFM TCC291
Request a Quote
Quick facts
| Availability | Confirmed on request |
| Category | Self-monitoring transmitters for the food industry |
| Warranty | 12-month (new) · 3-month (used/refurbished) |
Shipping & availability
When can TCC291 be shipped?
TCC291 is sourced on request — request a quote and we'll confirm the exact availability and shipping timeline for this specific unit.
Can I pick up TCC291 in person?
Local pickup from our Groningen, Netherlands warehouse may be possible — contact us before ordering to check availability and arrange a collection time.
Is express delivery available?
Yes — mention it when you request a quote for TCC291 and we'll include express shipping options in our reply.
My factory is down and I need this urgently — can you help?
For a critical breakdown, contact us directly at +31 (0)50-7110348 or sales@partnerplc.com — we can look into same-day courier or dedicated taxi/hotshot delivery for TCC291, subject to availability and destination.
Immediate notification of deviations in accuracy Improved quality assurance in between calibration intervals Robust design for permanently precise measurements even in demanding environments Transparent sensor monitoring thanks to logging of the diagnostic values Simulation function simplifies installation Precise analogue output and user-friendly communication via IO-Link
Specifications
Product characteristics
| Number of inputs and outputs | Number of digital outputs: 1; Number of analogue outputs: 1 |
| Measuring range | -25...160 °C; -13...320 °F |
| -25...160 °C | -13...320 °F |
| Communication interface | IO-Link |
| Process connection | clamp adapter Ø 6 mm |
| Installation length EL[mm] [mm] | 350 |
Application
| Special feature | Gold-plated contacts |
| Measuring element | 1 x Pt 1000 |
| Reference element | 1 x NTC |
| Media | liquids and gases |
| Pressure rating | 160 bar; 16 MPa |
| 160 bar | 16 MPa |
| Minimum installation depth[mm] [mm] | 15 |
Electrical data
| Operating voltage[V] [V] | 18...32 DC; ("supply class 2" to cULus) |
| Current consumption[mA] [mA] | 10; (24 V) |
| Protection class | III |
| Reverse polarity protection | yes |
| Power-on delay time[s] [s] | 6 |
| Integrated watchdog | yes |
Inputs / outputs
| Number of inputs and outputs | Number of digital outputs: 1; Number of analogue outputs: 1 |
Outputs
| Total number of outputs | 2 |
| Output signal | analogue signal; IO-Link; (calibration check status) |
| Electrical design | PNP/NPN |
| Number of digital outputs | 1 |
| Output function | normally closed; (diagnostic signal) |
| Max. voltage drop switching output DC[V] [V] | 2 |
| Permanent current rating of switching output DC[mA] [mA] | 100 |
| Diagnostic output | calibration check status and error diagnostics |
| Number of analogue outputs | 1 |
| Analogue current output[mA] [mA] | 4...20 |
| Max. load[Ω] [Ω] | (Ub - 15 V) x 50 |
| Short-circuit protection | yes |
| Type of short-circuit protection | pulsed |
| Overload protection | yes |
Measuring/setting range
| Probe length L[mm] [mm] | 350 |
| Measuring range | -25...160 °C; -13...320 °F |
| -25...160 °C | -13...320 °F |
| Note on measuring range | scalable |
| Factory setting | -10...150 °C / 14...302 °F |
| Calibration check limit[K] [K] | 0.5...3 |
| In steps of[K] [K] | 0.05 |
| Resolution of analogue output[K] [K] | 0.05 |
Accuracy / deviations
| Precision analogue output[K] [K] | ± 0,2 |
| Precision IO-Link[K] [K] | ± 0,2 |
| Temperature coefficient analogue output[% of the span / 10 K] [% of the span / 10 K] | < ± 0,02; (in case of deviation from the reference condition 25 ± 5 °C) |
| Temperature coefficient IO-Link[% of the span / 10 K] [% of the span / 10 K] | < ± 0,01; (in case of deviation from the reference condition 25 ± 5 °C) |
Response times
| Dynamic response T05 / T09[s] [s] | 1,5 / 4 |
Software / programming
| Parameter setting options | Display unit; scaling of the analogue output; calibration check limit; switching logic diagnostic output; simulation mode |
Interfaces
| Communication interface | IO-Link |
| Transmission type | COM2 (38,4 kBaud) |
| IO-Link revision | 1.1 |
| SDCI standard | IEC 61131-9 CDV |
| Profiles | BLOB; Binary Large Object transfer; Common - I&D; Identification and Diagnosis; Function; Measurement data, standard resolution |
| BLOB | Binary Large Object transfer |
| Common - I&D | Identification and Diagnosis |
| Function | Measurement data, standard resolution |
| SIO mode | yes |
| Required master port type | A |
| Process data analogue | 1 |
| Process data binary | 1 |
| Min. process cycle time[ms] [ms] | 4.4 |
| IO-Link resolution temperature[K] [K] | 0.01 |
| Supported DeviceIDs | default; 1129 |
| default | 1129 |
Operating conditions
| Ambient temperature[°C] [°C] | -25...70 |
| Note on ambient temperature | max. internal device temperature: 125 °C |
| Storage temperature[°C] [°C] | -40...100 |
| Protection | IP 68; IP 69K |
Tests / approvals
| EMC | DIN EN 61000-6-2; DIN EN 61000-6-3 |
| Shock resistance | DIN EN 68000-2-27; 50 g (11 ms) |
| DIN EN 68000-2-27 | 50 g (11 ms) |
| Vibration resistance | DIN EN 60068-2-6; 35 g (10...2000 Hz) |
| DIN EN 60068-2-6 | 35 g (10...2000 Hz) |
| MTTF[years] [years] | 329 |
| Note on approval | factory certificate available as download at www.factory-certificate.ifm |
| UL approval | UL approval no.; K021; File number UL; E217884 |
| UL approval no. | K021 |
| File number UL | E217884 |
Mechanical data
| Weight[g] [g] | 315.6 |
| Housing | cylindrical |
| Dimensions[mm] [mm] | Ø 50 / L = 393.5 |
| Materials | stainless steel (316L/1.4404); PEI; FKM; PFA |
| Materials (wetted parts) | stainless steel (316L/1.4404) |
| Process connection | clamp adapter Ø 6 mm |
| Surface characteristics Ra/Rz of the wetted parts | Ra < 0.8 µm |
| Probe diameter[mm] [mm] | 6 |
| Installation length EL[mm] [mm] | 350 |
Remarks
| Remarks | MS = set measuring span; operating voltage "supply class 2" according to cULus |
| Pack quantity | 1 pcs. |
Electrical connection
| Connector | 1 x M12; coding: A; Contacts: gold-plated |