IFM SF5702
Request a Quote
Quick facts
| Availability | Confirmed on request |
| Category | Modular flow monitoring |
| Warranty | 12-month (new) · 3-month (used/refurbished) |
Shipping & availability
When can SF5702 be shipped?
SF5702 is sourced on request — request a quote and we'll confirm the exact availability and shipping timeline for this specific unit.
Can I pick up SF5702 in person?
Local pickup from our Groningen, Netherlands warehouse may be possible — contact us before ordering to check availability and arrange a collection time.
Is express delivery available?
Yes — mention it when you request a quote for SF5702 and we'll include express shipping options in our reply.
My factory is down and I need this urgently — can you help?
For a critical breakdown, contact us directly at +31 (0)50-7110348 or sales@partnerplc.com — we can look into same-day courier or dedicated taxi/hotshot delivery for SF5702, subject to availability and destination.
Reliable monitoring of liquids and gases in pipes For connection to an evaluation unit Simple process connection via adapter Titanium materials for contact with the medium for use in aggressive media M12 connector for fast and easy connection
Specifications
Product characteristics
| Probe length L[mm] [mm] | 93 |
| Process connection | threaded connection M18 x 1,5 internal thread |
Application
| Media | Liquids; Gases; aggressive media |
| Medium temperature[°C] [°C] | -25...80 |
| Pressure rating | 100 bar; 10 MPa |
| 100 bar | 10 MPa |
Electrical data
| Connection to control monitor | VS3000 |
Measuring/setting range
| Probe length L[mm] [mm] | 93 |
| Setting range[cm/s] [cm/s] | 200...3000 |
| Greatest sensitivity[cm/s] [cm/s] | 200...800 |
Accuracy / deviations
| Temperature gradient[K/min] [K/min] | 300 |
Response times
| Response time[s] [s] | 1...10 |
Operating conditions
| Storage temperature[°C] [°C] | -25...80 |
| Protection | IP 67 |
Tests / approvals
| Shock resistance | DIN IEC 68-2-27; 50 g (11 ms) |
| DIN IEC 68-2-27 | 50 g (11 ms) |
| Vibration resistance | DIN IEC 68-2-6; 10 g (55...2000 Hz) |
| DIN IEC 68-2-6 | 10 g (55...2000 Hz) |
| MTTF[years] [years] | 8393.77 |
Mechanical data
| Weight[g] [g] | 68 |
| Housing | cylindrical |
| Dimensions[mm] [mm] | Ø 8.2 / L = 132 |
| Materials | titanium (3.7035); EPDM; ULTEM |
| Materials (wetted parts) | titanium (3.7035); O-ring: FKM 80 Shore A |
| Process connection | threaded connection M18 x 1,5 internal thread |
| Probe diameter[mm] [mm] | 8.2 |
| Installation length EL[mm] [mm] | 93 |
Remarks
| Pack quantity | 1 pcs. |
Electrical connection
| Connector | 1 x M12; coding: A; Maximum cable length: 100 m |