IFM PX3228
Request a Quote
Quick facts
| Availability | Confirmed on request |
| Category | Transmitters type PA |
| Warranty | 12-month (new) · 3-month (used/refurbished) |
Shipping & availability
When can PX3228 be shipped?
PX3228 is sourced on request — request a quote and we'll confirm the exact availability and shipping timeline for this specific unit.
Can I pick up PX3228 in person?
Local pickup from our Groningen, Netherlands warehouse may be possible — contact us before ordering to check availability and arrange a collection time.
Is express delivery available?
Yes — mention it when you request a quote for PX3228 and we'll include express shipping options in our reply.
My factory is down and I need this urgently — can you help?
For a critical breakdown, contact us directly at +31 (0)50-7110348 or sales@partnerplc.com — we can look into same-day courier or dedicated taxi/hotshot delivery for PX3228, subject to availability and destination.
Reliable detection of system pressure in industrial and mobile applications Precise analogue output With long-term stability thanks to high overload protection Lifespan of more than 100 million pressure cycles High shock and vibration resistance
Specifications
Product characteristics
| Number of inputs and outputs | Number of analogue outputs: 1 |
| Measuring range | 0...100 inH2O; 0...25 kPa |
| 0...100 inH2O | 0...25 kPa |
| Process connection | threaded connection 1/4" NPT external thread internal thread:M5 |
Application
| Special feature | Gold-plated contacts |
| Application | for industrial applications |
| Media | liquids and gases |
| Medium temperature[°C] [°C] | -25...90 |
| Min. burst pressure | 12043 inH2O; 3 MPa |
| 12043 inH2O | 3 MPa |
| Pressure rating | 2400 inH2O; 1 MPa |
| 2400 inH2O | 1 MPa |
| Type of pressure | relative pressure |
Electrical data
| Operating voltage[V] [V] | 9.6...32 DC |
| Min. insulation resistance[MΩ] [MΩ] | 100; (500 V DC) |
| Protection class | III |
| Reverse polarity protection | yes |
Inputs / outputs
| Number of inputs and outputs | Number of analogue outputs: 1 |
Outputs
| Total number of outputs | 1 |
| Output signal | analogue signal |
| Number of analogue outputs | 1 |
| Analogue current output[mA] [mA] | 4...20 |
| Max. load[Ω] [Ω] | 720; (Ub = 24 V; (Ub - 9,6 V) / 20 mA) |
| Overload protection | yes |
Measuring/setting range
| Measuring range | 0...100 inH2O; 0...25 kPa |
| 0...100 inH2O | 0...25 kPa |
Accuracy / deviations
| Repeatability[% of the span] [% of the span] | < 0,15; (with temperature fluctuations < 10 K) |
| Characteristics deviation[% of the span] [% of the span] | < ± 0,35 (BFSL) / < ± 0,75 (LS); (BFSL = Best Fit Straight Line; LS = limit value setting) |
| Long-term stability[% of the span] [% of the span] | < ± 0,05; (per 6 months) |
| Temperature coefficient zero point[% of the span / 10 K] [% of the span / 10 K] | 0,2; (0...80 °C) |
| Temperature coefficient span[% of the span / 10 K] [% of the span / 10 K] | 0,3; (0...80 °C) |
Response times
| Step response time analogue output[ms] [ms] | 3 |
Operating conditions
| Ambient temperature[°C] [°C] | -25...80 |
| Storage temperature[°C] [°C] | -40...100 |
| Protection | IP 65 |
Tests / approvals
| EMC | EN 61000-4-2 ESD; 4 kV CD / 8 kV AD; EN 61000-4-3 HF radiated; 30 V/m; EN 61000-4-4 Burst; 2 kV; EN 61000-4-6 HF conducted; 10 V; radiation of interference; according to the automotive directive 2004/104/EC / CISPR 25; immunity; according to the automotive directive 2004/104/EC / ISO 11452-2; HF radiated; 100 V/m; pulse resistance; ISO 7637-2 / severity level 3 |
| EN 61000-4-2 ESD | 4 kV CD / 8 kV AD |
| EN 61000-4-3 HF radiated | 30 V/m |
| EN 61000-4-4 Burst | 2 kV |
| EN 61000-4-6 HF conducted | 10 V |
| radiation of interference | according to the automotive directive 2004/104/EC / CISPR 25 |
| immunity | according to the automotive directive 2004/104/EC / ISO 11452-2 |
| HF radiated | 100 V/m |
| pulse resistance | ISO 7637-2 / severity level 3 |
| Shock resistance | DIN IEC 68-2-27; 50 g (11 ms) |
| DIN IEC 68-2-27 | 50 g (11 ms) |
| Vibration resistance | DIN IEC 68-2-6; 20 g (10...2000 Hz) |
| DIN IEC 68-2-6 | 20 g (10...2000 Hz) |
| MTTF[years] [years] | 555 |
| Pressure Equipment Directive | Sound engineering practice; can be used for group 2 fluids; group 1 fluids on request |
Mechanical data
| Weight[g] [g] | 212 |
| Housing | cylindrical |
| Dimensions[mm] [mm] | Ø 30 / L = 79.5 |
| Materials | stainless steel (316L/1.4404); FKM; PA; EPDM/X |
| Materials (wetted parts) | stainless steel (303/1.4305); ceramics; FKM |
| Min. pressure cycles | 100 million |
| Process connection | threaded connection 1/4" NPT external thread internal thread:M5 |
| Restrictor element integrated | no (can be retrofitted) |
Remarks
| Pack quantity | 1 pcs. |
Electrical connection
| Connector | 1 x M12; coding: A; Contacts: gold-plated |