IFM PU8500
Request a Quote
Quick facts
| Availability | Confirmed on request |
| Category | Transmitters for mobile applications |
| Warranty | 12-month (new) · 3-month (used/refurbished) |
Shipping & availability
When can PU8500 be shipped?
PU8500 is sourced on request — request a quote and we'll confirm the exact availability and shipping timeline for this specific unit.
Can I pick up PU8500 in person?
Local pickup from our Groningen, Netherlands warehouse may be possible — contact us before ordering to check availability and arrange a collection time.
Is express delivery available?
Yes — mention it when you request a quote for PU8500 and we'll include express shipping options in our reply.
My factory is down and I need this urgently — can you help?
For a critical breakdown, contact us directly at +31 (0)50-7110348 or sales@partnerplc.com — we can look into same-day courier or dedicated taxi/hotshot delivery for PU8500, subject to availability and destination.
For the reliable detection of the system pressure in mobile machines Robust stainless steel housing with high shock and vibration resistance Compact housing for use where space is restricted Lifespan of more than 60 million pressure cycles With long-term stability thanks to high repeatability and low linearity error
Specifications
Product characteristics
| Number of inputs and outputs | Number of analogue outputs: 1 |
| Measuring range | 0...400 bar; 0...5800 psi; 0...40 MPa |
| 0...400 bar | 0...5800 psi |
| Process connection | threaded connection G 1/4 external thread (DIN EN ISO 1179-2) |
Application
| Application | for mobile applications |
| Media | liquids and gases |
| Medium temperature[°C] [°C] | -40...125 |
| Min. burst pressure | 1700 bar; 24655 psi; 170 MPa |
| 1700 bar | 24655 psi |
| Pressure rating | 1000 bar; 14500 psi; 100 MPa |
| 1000 bar | 14500 psi |
| Note on pressure rating | static |
| Vacuum resistance | -1000 mbar; -0.1 MPa |
| -1000 mbar | -0.1 MPa |
| Type of pressure | relative pressure |
Electrical data
| Operating voltage[V] [V] | 8...32 DC |
| Current consumption[mA] [mA] | < 12 |
| Min. insulation resistance[MΩ] [MΩ] | 100; (500 V DC) |
| Protection class | III |
| Reverse polarity protection | yes |
| Power-on delay time[s] [s] | < 0.1 |
Inputs / outputs
| Number of inputs and outputs | Number of analogue outputs: 1 |
Outputs
| Total number of outputs | 1 |
| Output signal | analogue signal |
| Number of analogue outputs | 1 |
| Analogue voltage output[V] [V] | 0.5...4.5 |
| Min. load resistance[Ω] [Ω] | 2000 |
| Short-circuit proof | yes |
| Overload protection | yes |
Measuring/setting range
| Measuring range | 0...400 bar; 0...5800 psi; 0...40 MPa |
| 0...400 bar | 0...5800 psi |
Accuracy / deviations
| Repeatability[% of the span] [% of the span] | < ± 0,05; (with temperature fluctuations < 10 K) |
| Characteristics deviation[% of the span] [% of the span] | < ± 0,8; (incl. drift when overtightened, zero point and span error, non-linearity, hysteresis) |
| Linearity deviation[% of the span] [% of the span] | < ± 0,25 (BFSL) / < ± 0,5 (LS) |
| Hysteresis deviation[% of the span] [% of the span] | < ± 0,2 |
| Long-term stability[% of the span] [% of the span] | < ± 0,1; (per 6 months) |
| Temperature coefficient zero point[% of the span / 10 K] [% of the span / 10 K] | < ± 0,1 (0...80 °C); < ± 0,2 (-40...0 °C / 80...125 °C) |
| Temperature coefficient span[% of the span / 10 K] [% of the span / 10 K] | < ± 0,1 (0...80 °C); < ± 0,2 (-40...0 °C / 80...125 °C) |
Response times
| Step response time analogue output[ms] [ms] | 2 |
Operating conditions
| Ambient temperature[°C] [°C] | -40...100 |
| Storage temperature[°C] [°C] | -40...100 |
| Protection | IP 67; IP 69K |
Tests / approvals
| EMC | compliant with UN ECE R10, rev. 5; ISO 11452-2; 100 V/m; DIN EN 61326-1 |
| ISO 11452-2 | 100 V/m |
| Shock resistance | DIN EN 60068-2-27; 500 g (1 ms) |
| DIN EN 60068-2-27 | 500 g (1 ms) |
| Vibration resistance | DIN EN 60068-2-6; 20 g (10...2000 Hz) |
| DIN EN 60068-2-6 | 20 g (10...2000 Hz) |
| MTTF[years] [years] | 658 |
| Pressure Equipment Directive | Sound engineering practice; can be used for group 2 fluids; group 1 fluids on request |
Mechanical data
| Weight[g] [g] | 58.5 |
| Housing | cylindrical |
| Dimensions[mm] [mm] | Ø 19 / L = 66 |
| Materials | stainless steel (630/1.4542/17-4 PH); stainless steel (316L/1.4404); PEI |
| Materials (wetted parts) | stainless steel (630/1.4542/17-4 PH) |
| Min. pressure cycles | 60 million; (at 1.2 times nominal pressure) |
| Tightening torque[Nm] [Nm] | 25...35; (recommended tightening torque; depends on the lubrication, the seal and the pressure load) |
| Process connection | threaded connection G 1/4 external thread (DIN EN ISO 1179-2) |
| Process connection sealing | HNBR (DIN EN ISO 1179-2) |
| Restrictor element integrated | yes |
Remarks
| Remarks | BFSL = Best Fit Straight Line; LS = limit value setting |
| Pack quantity | 1 pcs. |
Electrical connection
| Connector | 1 x M12; coding: A; Maximum cable length: 30 m |