IFM PP004E
Quick facts
| Availability | Confirmed on request |
| Category | Two switching outputs |
| Warranty | 12-month (new) · 3-month (used/refurbished) |
Shipping & availability
When can PP004E be shipped?
PP004E is sourced on request — request a quote and we'll confirm the exact availability and shipping timeline for this specific unit.
Can I pick up PP004E in person?
Local pickup from our Groningen, Netherlands warehouse may be possible — contact us before ordering to check availability and arrange a collection time.
Is express delivery available?
Yes — mention it when you request a quote for PP004E and we'll include express shipping options in our reply.
My factory is down and I need this urgently — can you help?
For a critical breakdown, contact us directly at +31 (0)50-7110348 or sales@partnerplc.com — we can look into same-day courier or dedicated taxi/hotshot delivery for PP004E, subject to availability and destination.
Suited for use in mobile machines Two switching outputs, one of which can be configured as diagnostic output High shock and vibration resistance Excellent EMC resistance User-friendly communication and parameterisation via IO-Link
Specifications
Product characteristics
| Number of inputs and outputs | Number of digital outputs: 2 |
| Measuring range | -1...10 bar; -14.5...145 psi; -100...1000 kPa; -0.1...1 MPa |
| -1...10 bar | -14.5...145 psi |
| Process connection | threaded connection G 1/4 external thread internal thread:M5 |
Application
| Application | for mobile applications |
| Media | liquids and gases |
| Medium temperature[°C] [°C] | -25...90 |
| Min. burst pressure | 150 bar; 2175 psi; 15 MPa |
| 150 bar | 2175 psi |
| Pressure rating | 75 bar; 1087 psi; 7.5 MPa |
| 75 bar | 1087 psi |
| Type of pressure | relative pressure; vacuum |
Electrical data
| Operating voltage[V] [V] | 9.6...36 DC; (communication mode: 18...32) |
| Current consumption[mA] [mA] | < 45 |
| Min. insulation resistance[MΩ] [MΩ] | 100; (500 V DC) |
| Protection class | III |
| Reverse polarity protection | yes |
| Power-on delay time[s] [s] | 0.3 |
Inputs / outputs
| Number of inputs and outputs | Number of digital outputs: 2 |
Outputs
| Total number of outputs | 2 |
| Output signal | switching signal; IO-Link; (configurable) |
| Electrical design | PNP |
| Number of digital outputs | 2 |
| Output function | normally open / normally closed; (parameterisable) |
| Max. voltage drop switching output DC[V] [V] | 2 |
| Permanent current rating of switching output DC[mA] [mA] | 250 |
| Switching frequency DC[Hz] [Hz] | 170 |
| Short-circuit protection | yes |
| Type of short-circuit protection | pulsed |
| Overload protection | yes |
Measuring/setting range
| Measuring range | -1...10 bar; -14.5...145 psi; -100...1000 kPa; -0.1...1 MPa |
| -1...10 bar | -14.5...145 psi |
| Set point SP | -0.9...10 bar; -13...145 psi; -0.09...1 MPa |
| -0.9...10 bar | -13...145 psi |
| Reset point rP | -0.95...9.95 bar; -14...144 psi; -0.095...0.995 MPa |
| -0.95...9.95 bar | -14...144 psi |
| In steps of | 0.05 bar; 1 psi; 0.005 MPa |
| 0.05 bar | 1 psi |
| Factory setting | SP1 = 2.50 bar; rP1 = 2.30 bar; SP2 = 7.50 bar; rP2 = 7.30 bar; OUT1 = Hno; OUT2 = Hno |
Accuracy / deviations
| Switch point accuracy[% of the span] [% of the span] | < ± 0,5 |
| Repeatability[% of the span] [% of the span] | < ± 0,1; (with temperature fluctuations < 10 K) |
| Characteristics deviation[% of the span] [% of the span] | < ± 0,25 (BFSL) / < ± 0,5 (LS); (BFSL = Best Fit Straight Line; LS = limit value setting) |
| Zero-point stabilisation[% of the span] [% of the span] | IO-Link; 1,0; (see operating instructions zero-point behaviour) |
| switching output, display | 1,0 |
| IO-Link | 1,0; (see operating instructions zero-point behaviour) |
| Hysteresis deviation[% of the span] [% of the span] | < ± 0,1 |
| Long-term stability[% of the span] [% of the span] | < ± 0,1; (per year) |
| Temperature coefficient zero point[% of the span / 10 K] [% of the span / 10 K] | < ± 0,2; (0...80 °C) |
| Temperature coefficient span[% of the span / 10 K] [% of the span / 10 K] | < ± 0,2; (0...80 °C) |
Response times
| Response time[ms] [ms] | < 3 |
| Damping process value dAP in steps[s] [s] | 0,003 - 0,006 - 0,010 - 0,017 - 0,060 - 0,125 - 0,250 - 0,500 |
Interfaces
| Communication interface | IO-Link |
| Transmission type | COM2 (38,4 kBaud) |
| IO-Link revision | 1.0 |
| SIO mode | yes |
| Required master port type | A |
| Process data analogue | 1 |
| Process data binary | 2 |
| Min. process cycle time[ms] [ms] | 2.3 |
| Supported DeviceIDs | default; 6 |
| default | 6 |
Operating conditions
| Ambient temperature[°C] [°C] | -25...85 |
| Storage temperature[°C] [°C] | -40...100 |
| Protection | IP 68; (7 days / 1 m water depth / 0.1 bar) |
Tests / approvals
| EMC | immunity; EN 61000-6-2; EN 61000-4-2 ESD; 4 kV contact discharge / 15 kV air discharge; EN 61000-4-3 HF radiated; 20 V/m; EN 61000-4-4 Burst; 4 kV coupling clamp; EN 61000-4-5 Surge; 0,5 kV supply / 1 kV signal for DC units; EN 61000-4-6 HF conducted; 10 V; immunity; ECE R 10, Rev. 5; absorber chamber test to ISO 11452-2:; 80 V/m |
| immunity | ECE R 10, Rev. 5 |
| EN 61000-4-2 ESD | 4 kV contact discharge / 15 kV air discharge |
| EN 61000-4-3 HF radiated | 20 V/m |
| EN 61000-4-4 Burst | 4 kV coupling clamp |
| EN 61000-4-5 Surge | 0,5 kV supply / 1 kV signal for DC units |
| EN 61000-4-6 HF conducted | 10 V |
| absorber chamber test to ISO 11452-2: | 80 V/m |
| Shock resistance | DIN IEC 60068-2-27 / DIN IEC 60068-2-29; 1000 g; DIN EN 61373; category 3 |
| DIN IEC 60068-2-27 / DIN IEC 60068-2-29 | 1000 g |
| DIN EN 61373 | category 2 |
| Vibration resistance | DIN IEC 68-2-6; 20 g (10...2000 Hz); DIN EN 60068-2-64; 14 g; DIN EN 61373; category 2 |
| DIN IEC 68-2-6 | 20 g (10...2000 Hz) |
| DIN EN 60068-2-64 | 14 g |
| MTTF[years] [years] | 310 |
| Pressure Equipment Directive | Sound engineering practice; can be used for group 2 fluids; group 1 fluids on request |
| Railway applications | DIN EN 50155; Klasse T3, C1, S1 |
| DIN EN 50155 | Klasse T3, C1, S1 |
Mechanical data
| Weight[g] [g] | 224 |
| Housing | cylindrical |
| Dimensions[mm] [mm] | Ø 30 / L = 79.5 |
| Materials | stainless steel (304/1.4301); FKM; EPDM/X; PA |
| Materials (wetted parts) | stainless steel (303/1.4305); ceramics; FKM |
| Min. pressure cycles | 100 million |
| Process connection | threaded connection G 1/4 external thread internal thread:M5 |
| Restrictor element integrated | no (can be retrofitted) |
Displays / operating elements
| Display | operation; 2 x LED, green; switching status; 2 x LED, yellow |
| operation | 2 x LED, green |
| switching status | 2 x LED, yellow |
| Teach function | yes |
Remarks
| Remarks | with reference to UL: "limited voltage" with overcurrent protection in accordance with UL508 |
| Pack quantity | 1 pcs. |
Electrical connection
| Connector | 1 x M12; coding: A |