IFM PG1406
Quick facts
| Availability | Confirmed on request |
| Category | All pressure sensors / vacuum sensors |
| Warranty | 12-month (new) · 3-month (used/refurbished) |
Shipping & availability
When can PG1406 be shipped?
PG1406 is sourced on request — request a quote and we'll confirm the exact availability and shipping timeline for this specific unit.
Can I pick up PG1406 in person?
Local pickup from our Groningen, Netherlands warehouse may be possible — contact us before ordering to check availability and arrange a collection time.
Is express delivery available?
Yes — mention it when you request a quote for PG1406 and we'll include express shipping options in our reply.
My factory is down and I need this urgently — can you help?
For a critical breakdown, contact us directly at +31 (0)50-7110348 or sales@partnerplc.com — we can look into same-day courier or dedicated taxi/hotshot delivery for PG1406, subject to availability and destination.
Manometer display, pressure switch and transmitter in one unit Excellent readability also over a long distance Rotatable display with LED indication for flexible visualisation Programmable switching output and scalable analogue output Robust stainless steel housing for use in harsh industrial environments Convenient operation via buttons or parameter setting via IO-Link
Specifications
Product characteristics
| Number of inputs and outputs | Number of digital outputs: 1; Number of analogue outputs: 1 |
| Measuring range | -0.124...2.5 bar; -1.8...36.26 psi |
| -0.124...2.5 bar | -1.8...36.26 psi |
| Process connection | threaded connection G 1/2 external thread DIN EN 837-1 |
Application
| Special feature | Gold-plated contacts |
| Application | for industrial applications |
| Media | liquids and gases |
| Medium temperature[°C] [°C] | -25...80; (higher temperature upon request) |
| Min. burst pressure | 50 bar; 725 psi |
| 50 bar | 725 psi |
| Pressure rating | 20 bar; 290 psi |
| 20 bar | 290 psi |
| Vacuum resistance | -1000 mbar; 14.5 psi |
| -1000 mbar | 14.5 psi |
| Type of pressure | relative pressure; vacuum |
Electrical data
| Operating voltage[V] [V] | 18...30 DC |
| Current consumption[mA] [mA] | 25...260 |
| Min. insulation resistance[MΩ] [MΩ] | 100; (500 V DC) |
| Protection class | III |
| Reverse polarity protection | yes |
| Power-on delay time[s] [s] | < 0.5 |
| Integrated watchdog | yes |
Inputs / outputs
| Number of inputs and outputs | Number of digital outputs: 1; Number of analogue outputs: 1 |
Outputs
| Total number of outputs | 2 |
| Output signal | switching signal; analogue signal; IO-Link |
| Electrical design | PNP/NPN |
| Number of digital outputs | 1 |
| Output function | normally open / normally closed; (parameterisable) |
| Max. voltage drop switching output DC[V] [V] | 2 |
| Permanent current rating of switching output DC[mA] [mA] | 100 |
| Switching frequency DC[Hz] [Hz] | 125 |
| Number of analogue outputs | 1 |
| Analogue current output[mA] [mA] | 4...20, invertible; (scalable) |
| Max. load[Ω] [Ω] | 500 |
| Short-circuit protection | yes |
| Type of short-circuit protection | pulsed |
| Overload protection | yes |
Measuring/setting range
| Measuring range | -0.124...2.5 bar; -1.8...36.26 psi |
| -0.124...2.5 bar | -1.8...36.26 psi |
| Set point SP | -0.124...2.5 bar; -1.8...36.26 psi |
| Analogue start point | -0.124...2 bar; -1.8...29.01 psi |
| -0.124...2 bar | -1.8...29.01 psi |
| Analogue end point | 0.376...2.5 bar; 5.45...36.26 psi |
| 0.376...2.5 bar | 5.45...36.26 psi |
| In steps of | 0.001 bar; 0.05 psi |
| 0.001 bar | 0.05 psi |
| Factory setting | SP1 = 9.06 psi; SP2 = 8.34 psi; ASP = 0.00 psi; AEP = 36.26 psi; dAP = 0.06 s; dAA = 0.06 s |
Accuracy / deviations
| Switch point accuracy[% of the span] [% of the span] | < ± 0,5; (DIN EN IEC 62828-1; Turn down 1:1) |
| Repeatability[% of the span] [% of the span] | < ± 0,1; (with temperature fluctuations < 10 K; Turn down 1:1) |
| Characteristics deviation[% of the span] [% of the span] | < ± 0,5; (DIN IEC EN 62828-1 incl. zero point and span error, non-linearity, hysteresis; Turn down 1:1) |
| Zero-point stabilisation[% of the span] [% of the span] | IO-Link, analogue output; 0,2; (see operating instructions zero-point behaviour); display, switching output; 0,1 |
| IO-Link, analogue output | 0,2; (see operating instructions zero-point behaviour) |
| display, switching output | 0,1 |
| Hysteresis deviation[% of the span] [% of the span] | < ± 0,15; (Turn down 1:1 -25...80°C) |
| Long-term stability[% of the span] [% of the span] | < ± 0,1; (Turn down 1:1; per year) |
| Temperature coefficient zero point[% of the span / 10 K] [% of the span / 10 K] | < ± 0,25; (0...70 °C) |
| Temperature coefficient span[% of the span / 10 K] [% of the span / 10 K] | < ± 0,25; (0...70 °C) |
Response times
| Min. response time of switching output (dAP)[ms] [ms] | 3 |
| Damping process value dAP[s] [s] | 0...99.99 |
| Damping for the analogue output dAA[s] [s] | 0...99.99 |
| Step response time analogue output[ms] [ms] | 7 |
Interfaces
| Communication interface | IO-Link |
| Transmission type | COM3 (230,4 kBaud) |
| IO-Link revision | 1.1 |
| SDCI standard | IEC 61131-9 |
| Profiles | Smart Sensor - SSP 4.2.1; Measuring and Switching Sensor, high resolution, 1 channel; BLOB; Binary Large Object transfer; Common - I&D; Identification and Diagnosis; Extension; Sensor Control Wide; Extension; Quantity detection, switches when value exceeds the setpoint; Function; Locator; Function; ProductURI |
| Smart Sensor - SSP 4.2.1 | Measuring and Switching Sensor, high resolution, 1 channel |
| BLOB | Binary Large Object transfer |
| Common - I&D | Identification and Diagnosis |
| Extension | Quantity detection, switches when value exceeds the setpoint |
| Function | ProductURI |
| SIO mode | yes |
| Required master port type | A |
| Min. process cycle time[ms] [ms] | 1.3 |
| IO-Link resolution pressure[bar] [bar] | 0.0001 |
| IO-Link process data (cyclical) | pressure; 32; device status; 4; binary switching information pressure; 2 |
| pressure | 32 |
| device status | 4 |
| binary switching information pressure | 2 |
| IO-Link functions (acyclical) | application specific tag; internal temperature; operating hours counter; switching cycles counter; Pressure peak counter |
| Supported DeviceIDs | default; 1877 |
| default | 1877 |
Operating conditions
| Ambient temperature[°C] [°C] | -25...70 |
| Storage temperature[°C] [°C] | -40...100 |
| Protection | IP 67; IP 69; (to DIN EN 60529) |
Tests / approvals
| EMC | DIN EN 61326-1 |
| Shock resistance | DIN EN 60068-2-27; 50 g (11 ms) |
| DIN EN 60068-2-27 | 50 g (11 ms) |
| Vibration resistance | DIN EN 60068-2-6; 10 g (10...2000 Hz) |
| DIN EN 60068-2-6 | 10 g (10...2000 Hz) |
| MTTF[years] [years] | 115 |
| Embedded software included | yes |
| UL approval | UL approval no.; J060; File number UL; E174189 |
| UL approval no. | J060 |
| File number UL | E174189 |
Mechanical data
| Weight[g] [g] | 703.1 |
| Housing | manometer housing |
| Dimensions[mm] [mm] | 160 x 100 x 57 |
| Materials | Housing: stainless steel (316L/1.4404); M12 connector: PPSU; Sealing: FKM; pressure compensation element: PTFE; viewing glass: laminated safety glass 4 mm |
| Materials (wetted parts) | measuring cell: Al2O3 (ceramics); Process connection: stainless steel (316L/1.4404); Sealing: FKM |
| Min. pressure cycles | 100 million |
| Process connection | threaded connection G 1/2 external thread DIN EN 837-1 |
| Restrictor element integrated | no (can be retrofitted) |
Displays / operating elements
| 3 | optical operating keys |
| Display | display rotation: 320° |
| Pointer | LED, white ; 72 steps |
| LED bar graph | multi-colour ; 72 steps |
| measured values | alphanumeric display, white 4-digit |
| switching status | LED, yellow |
| device status | LED, red/green |
| Display unit | bar; psi |
| Operating elements | 3; optical operating keys |
Remarks
| Pack quantity | 1 pcs. |
Electrical connection
| Connector | 1 x M12; coding: A; Contacts: gold-plated |