IFM PA3226
Request a Quote
Quick facts
| Availability | Confirmed on request |
| Category | Transmitters type PA |
| Warranty | 12-month (new) · 3-month (used/refurbished) |
Shipping & availability
When can PA3226 be shipped?
PA3226 is sourced on request — request a quote and we'll confirm the exact availability and shipping timeline for this specific unit.
Can I pick up PA3226 in person?
Local pickup from our Groningen, Netherlands warehouse may be possible — contact us before ordering to check availability and arrange a collection time.
Is express delivery available?
Yes — mention it when you request a quote for PA3226 and we'll include express shipping options in our reply.
My factory is down and I need this urgently — can you help?
For a critical breakdown, contact us directly at +31 (0)50-7110348 or sales@partnerplc.com — we can look into same-day courier or dedicated taxi/hotshot delivery for PA3226, subject to availability and destination.
Precise linear 4...20 mA output signal High repeatability and low linearity error With long-term stability thanks to high overload protection Robust stainless steel housing for use in harsh industrial environments Wide operating temperature range
Specifications
Product characteristics
| Number of inputs and outputs | Number of analogue outputs: 1 |
| Measuring range | 0...2.5 bar; 0...2500 mbar; 0...36 psi; 0...250 kPa |
| 0...2.5 bar | 0...2500 mbar |
| Process connection | threaded connection 1/4" NPT internal thread |
Application
| Special feature | Gold-plated contacts |
| Application | for industrial applications |
| Media | liquids and gases |
| Medium temperature[°C] [°C] | -25...90; (on request: -40...90 °C) |
| Min. burst pressure | 50 bar; 725 psi; 5 MPa |
| 50 bar | 725 psi |
| Pressure rating | 20 bar; 290 psi; 2 MPa |
| 20 bar | 290 psi |
| Type of pressure | relative pressure |
Electrical data
| Operating voltage[V] [V] | 9.6...32 DC |
| Min. insulation resistance[MΩ] [MΩ] | 100; (500 V DC) |
| Protection class | III |
| Reverse polarity protection | yes |
Inputs / outputs
| Number of inputs and outputs | Number of analogue outputs: 1 |
Outputs
| Total number of outputs | 1 |
| Output signal | analogue signal |
| Number of analogue outputs | 1 |
| Analogue current output[mA] [mA] | 4...20 |
| Max. load[Ω] [Ω] | 720; (Ub = 24 V; (Ub - 9,6 V) / 20 mA) |
| Overload protection | yes |
Measuring/setting range
| Measuring range | 0...2.5 bar; 0...2500 mbar; 0...36 psi; 0...250 kPa |
| 0...2.5 bar | 0...2500 mbar |
Accuracy / deviations
| Repeatability[% of the span] [% of the span] | < 0,1; (with temperature fluctuations < 10 K) |
| Characteristics deviation[% of the span] [% of the span] | < ± 0,25 (BFSL) / < ± 0,5 (LS); (BFSL = Best Fit Straight Line; LS = limit value setting) |
| Long-term stability[% of the span] [% of the span] | < ± 0,05; (per 6 months) |
| Temperature coefficient zero point[% of the span / 10 K] [% of the span / 10 K] | 0,1; (0...80 °C) |
| Temperature coefficient span[% of the span / 10 K] [% of the span / 10 K] | 0,2; (0...80 °C) |
Response times
| Step response time analogue output[ms] [ms] | 3 |
Operating conditions
| Ambient temperature[°C] [°C] | -25...80 |
| Storage temperature[°C] [°C] | -40...100 |
| Protection | IP 65 |
Tests / approvals
| EMC | EN 61000-4-2 ESD; 4 kV CD / 8 kV AD; EN 61000-4-3 HF radiated; 30 V/m; EN 61000-4-4 Burst; 2 kV; EN 61000-4-6 HF conducted; 10 V; radiation of interference; according to the automotive directive 2004/104/EC; CISPR 25; immunity; according to the automotive directive 2004/104/EC; ISO 11452-2 HF radiated; 100 V/m; ISO 7637-2 pulse; severity level 4 |
| EN 61000-4-2 ESD | 4 kV CD / 8 kV AD |
| EN 61000-4-3 HF radiated | 30 V/m |
| EN 61000-4-4 Burst | 2 kV |
| EN 61000-4-6 HF conducted | 10 V |
| radiation of interference | according to the automotive directive 2004/104/EC |
| immunity | according to the automotive directive 2004/104/EC |
| ISO 11452-2 HF radiated | 100 V/m |
| ISO 7637-2 pulse | severity level 4 |
| Shock resistance | DIN EN 60068-2-27; 50 g (11 ms); DIN EN 61373; category 3 |
| DIN EN 60068-2-27 | 50 g (11 ms) |
| DIN EN 61373 | category 2 |
| Vibration resistance | DIN EN 60068-2-6; 20 g (10...2000 Hz); DIN EN 61373; category 2 |
| DIN EN 60068-2-6 | 20 g (10...2000 Hz) |
| MTTF[years] [years] | 506 |
| Pressure Equipment Directive | Sound engineering practice; can be used for group 2 fluids; group 1 fluids on request |
| Railway applications | DIN EN 50155 / IEC 60571; Klasse T3, C1, S1 |
| DIN EN 50155 / IEC 60571 | Klasse T3, C1, S1 |
Mechanical data
| Weight[g] [g] | 221.5 |
| Housing | cylindrical |
| Dimensions[mm] [mm] | Ø 30 / L = 75 |
| Materials | stainless steel (316L/1.4404); FKM; PA; EPDM/X |
| Materials (wetted parts) | stainless steel (303/1.4305); ceramics; FKM |
| Min. pressure cycles | 100 million |
| Process connection | threaded connection 1/4" NPT internal thread |
| Restrictor element integrated | no (can be retrofitted) |
Remarks
| Pack quantity | 1 pcs. |
Electrical connection
| Connector | 1 x M12; coding: A; Contacts: gold-plated |