Quick facts
| Availability | Confirmed on request |
| Category | All inductive sensors |
| Warranty | 12-month (new) · 3-month (used/refurbished) |
Shipping & availability
When can IM0013 be shipped?
IM0013 is sourced on request — request a quote and we'll confirm the exact availability and shipping timeline for this specific unit.
Can I pick up IM0013 in person?
Local pickup from our Groningen, Netherlands warehouse may be possible — contact us before ordering to check availability and arrange a collection time.
Is express delivery available?
Yes — mention it when you request a quote for IM0013 and we'll include express shipping options in our reply.
My factory is down and I need this urgently — can you help?
For a critical breakdown, contact us directly at +31 (0)50-7110348 or sales@partnerplc.com — we can look into same-day courier or dedicated taxi/hotshot delivery for IM0013, subject to availability and destination.
Long sensing range for use in conveying With combined AC/DC output and two-wire technology Output function normally open / normally closed programmable Robust housing for use in harsh industrial environments Large operating voltage range
Specifications
Product characteristics
| Output function | normally open / normally closed; (selectable) |
| Sensing range[mm] [mm] | 20 |
| Housing | rectangular |
| Dimensions[mm] [mm] | 40 x 40 x 120 |
Electrical data
| Operating voltage[V] [V] | 20...250 AC/DC |
| Protection class | II |
| Reverse polarity protection | no |
Outputs
| Output function | normally open / normally closed; (selectable) |
| Max. voltage drop switching output DC[V] [V] | 6 |
| Max. voltage drop switching output AC[V] [V] | 6.5 |
| Minimum load current[mA] [mA] | 5 |
| Max. leakage current[mA] [mA] | 2.5 (250 V AC) / 1.3 (110 V AC) / 0.8 (24 V DC) |
| Permanent current rating of switching output AC[mA] [mA] | 250; (350 (...50 °C)) |
| Permanent current rating of switching output DC[mA] [mA] | 100 |
| Short-time current rating of switching output[mA] [mA] | 2200; (20 ms / 0,5 Hz) |
| Switching frequency AC[Hz] [Hz] | 20 |
| Switching frequency DC[Hz] [Hz] | 55 |
| Short-circuit proof | no |
| Overload protection | no |
Detection zone
| Sensing range[mm] [mm] | 20 |
| Real sensing range Sr[mm] [mm] | 20 ± 10 % |
| Operating distance[mm] [mm] | 0...16.2 |
Accuracy / deviations
| Correction factor | steel: 1 / stainless steel: 0.7 / brass: 0.4 / aluminium: 0.3 / copper: 0.2 |
| Hysteresis[% of Sr] [% of Sr] | 1...15 |
| Switch point drift[% of Sr] [% of Sr] | -10...10 |
Operating conditions
| Ambient temperature[°C] [°C] | -25...80 |
| Protection | IP 65 |
Tests / approvals
| EMC | EN 60947-5-2; EN 55011; class B |
| EN 55011 | class B |
| MTTF[years] [years] | 604 |
| UL approval | Ta; 0...40 °C; Enclosure type; Type 1; File number UL; E174191 |
| Ta | -25...60 °C |
| Enclosure type | Type 1 |
| File number UL | E174191 |
| CSA approval | Ta; -25...60 °C; Classification; Class I; Div. 2; Groups A, B, C, D; T4; Class II; Div. 2; Groups F, G; T135 °C; Class III |
| Classification | Class I; Div. 2; Groups A, B, C, D; T4 |
Mechanical data
| Weight[g] [g] | 193 |
| Housing | rectangular |
| Mounting | non-flush mountable |
| Dimensions[mm] [mm] | 40 x 40 x 120 |
| Materials | PPE |
Displays / operating elements
| Display | switching status; 1 x LED, red |
| switching status | 1 x LED, red |
Electrical connection
| Required protection | miniature fuse to IEC60127-2 sheet 1; ≤ 2 A; fast acting |
Remarks
| Remarks | Recommendation: Check the safe functioning of the unit after a short circuit.; 5 positions of the active zone possible |
| Pack quantity | 1 pcs. |
Electrical connection
| terminals | ...2.5 mm²; Cable sheath: Ø 7...13 mm |