IFM GF762S
Request a Quote
Quick facts
| Availability | Confirmed on request |
| Category | Fail-safe inductive sensors |
| Warranty | 12-month (new) · 3-month (used/refurbished) |
Shipping & availability
When can GF762S be shipped?
GF762S is sourced on request — request a quote and we'll confirm the exact availability and shipping timeline for this specific unit.
Can I pick up GF762S in person?
Local pickup from our Groningen, Netherlands warehouse may be possible — contact us before ordering to check availability and arrange a collection time.
Is express delivery available?
Yes — mention it when you request a quote for GF762S and we'll include express shipping options in our reply.
My factory is down and I need this urgently — can you help?
For a critical breakdown, contact us directly at +31 (0)50-7110348 or sales@partnerplc.com — we can look into same-day courier or dedicated taxi/hotshot delivery for GF762S, subject to availability and destination.
Certified to the following standards: EN 60947-5-3, IEC 61508 and ISO 13849 Connection to safety PLC, safe AS-i modules or safe evaluation units Ensuring operator and machine safety Stainless steel sensing face High protection rating
Specifications
Product characteristics
| Electrical design | PNP |
| Enable zone[mm] [mm] | 0...1.5 |
| Housing | threaded type |
| Dimensions[mm] [mm] | M12 x 1 / L = 60 |
Application
| Special feature | Gold-plated contacts; Full-metal housing |
| Type of operation | permanent operation |
| Safety-related sub-function | safe state when properly undamped |
| Application | Use in hygienic areas / regular cleaning processes |
Electrical data
| Operating voltage[V] [V] | 10...30 DC |
| Rated insulation voltage[V] [V] | 60 |
| Current consumption[mA] [mA] | < 10; (24 V) |
| Protection class | III |
| Reverse polarity protection | yes |
| Max. power-on delay time[ms] [ms] | 500 |
Outputs
| Electrical design | PNP |
| Max. voltage drop switching output DC[V] [V] | 2.5 |
| Number of OSSD outputs | 2 |
| Max. current load per OSSD output[mA] [mA] | 50 |
| Output data | Interface type C class 1 |
| Output voltage at 24 V | compatible with EN 61131-2 inputs type 1, 2 |
| Short-circuit protection | yes |
| Overload protection | yes |
| Max. capacitive load CL_max[nF] [nF] | 20 |
Detection zone
| Enable zone[mm] [mm] | 0...1.5 |
| Safe switch-off distance sAs (sar)[mm] [mm] | 6 |
Accuracy / deviations
| Correction factor | steel: 1 / stainless steel: 0.6 / brass: 0.7 / aluminium: 0.6 / copper: 0.3 |
Response times
| Response time when approaching the enable zone, turn-on time (ton)[ms] [ms] | 20 |
| Response time to safety request, turn-off time (toff)[ms] [ms] | 20 |
| Risk time / error handling time (toff max)[ms] [ms] | 100 |
Operating conditions
| Ambient temperature[°C] [°C] | -25...100 |
| Max. height above sea level[m] [m] | 3000 |
| Ionising radiation | not permissible |
| Protection | IP 65; IP 66; IP 67; IP 68; IP 69K |
| Chemical media | the following media were tested for 28 days at 40 °C and with a concentration of 5 %; P3-topax 19; P3-topax 56; P3-topax 66; Topactive OKTO |
| the following media were tested for 28 days at 40 °C and with a concentration of 5 % | P3-topax 19 |
Tests / approvals
| EMC | industrial environments; EN 60947-5-3; EN 61000-4-2 ESD; 6 kV CD / 8 kV AD; EN 61000-4-3 HF radiated; 20 V/m 80...1000 MHz; EN 61000-4-3 HF radiated; 10 V/m 1,4...2,0 GHz / 3 V/m 2,0...6,0 GHz; EN 61000-4-4 Burst; 2 kV; EN 61000-4-5 Surge; 2 kV; EN 61000-4-6 HF conducted; 10 V; EN 61000-4-8; 30 A/m 50/60 Hz / 1000 A/m 0 Hz; EN 55011; class B |
| EN 61000-4-2 ESD | 6 kV CD / 8 kV AD |
| EN 61000-4-3 HF radiated | 10 V/m 1,4...2,0 GHz / 3 V/m 2,0...6,0 GHz |
| EN 61000-4-4 Burst | 2 kV |
| EN 61000-4-5 Surge | 2 kV |
| EN 61000-4-6 HF conducted | 10 V |
| EN 61000-4-8 | 30 A/m 50/60 Hz / 1000 A/m 0 Hz |
| EN 55011 | class B |
| Shock resistance | EN 60068-2-27 Ea; 100 g 11 ms half-sine; 3 shocks each in every direction of the 3 coordinate axes |
| EN 60068-2-27 Ea | 40 g 6 ms; 4000 shocks each in every direction of the 3 coordinate axes |
| Continuous shock resistance | EN 60068-2-27 Ea; 40 g 6 ms; 4000 shocks each in every direction of the 3 coordinate axes |
| Fast temperature change | EN 60068-2-14 Nc; TA = 0 °C; TB = 100 °C; t1 = 30 min; t2 = 10 s 50 cycles |
| EN 60068-2-14 Nc | TA = 0 °C; TB = 100 °C; t1 = 30 min; t2 = 10 s 50 cycles |
| Vibration resistance | EN 60068-2-6 Fc; 20 g (10...3000 Hz) / 50 sweep cycles, 1 octave per minute, in 3 axes |
| EN 60068-2-6 Fc | 20 g (10...3000 Hz) / 50 sweep cycles, 1 octave per minute, in 3 axes |
Safety classification
| Complies with the requirements | ISO 13849-1 category 2, PL d; IEC 61508 SIL 2, HFT 0, SC 2 |
| Mission time TM[h] [h] | ≤ 87600 |
| Mission time TM (additional indication) | industrial environments Temperature range -25...70 °C ≤ 175200 |
| PFH[1/h] [1/h] | < 1,5E-07 |
Mechanical data
| Weight[g] [g] | 33.05 |
| Housing | threaded type |
| Mounting | flush mountable |
| Dimensions[mm] [mm] | M12 x 1 / L = 60 |
| Thread designation | M12 x 1 |
| Materials | threaded sleeve: stainless steel (316L/1.4404); sensing face: stainless steel (316L/1.4404); LED window: PEI; LED Sealing: PU; lock nuts: stainless steel (316L/1.4404) |
| Tightening torque[Nm] [Nm] | 15 |
| Full-metal housing | yes |
Displays / operating elements
| Display | Display switching status; 4 LED, yellow |
| Display switching status | 4 LED, yellow |
Accessories
| Items supplied | lock nuts: 2 |
Remarks
| Remarks | can be used in applications up to SIL 2 in accordance with IEC 62061; Unless stated otherwise, all data refer to the reference target plate to IEC 60947-5-2 over the whole temperature range.; (FE360 = ST37-2K) 12x12x1 mm; the correction factors apply to an ambient temperature of 20°C; do not use a correction factor for the safe switch-off distance sAs/(sar) |
| Pack quantity | 1 pcs. |
Electrical connection - plug
| Connector | 1 x M12; coding: A; Contacts: gold-plated |