Available on request

IFM CP100S

MPN: CP100S · Brand: IFM
Price on request
Request a Quote

A real person replies, typically within 1 business day — see our privacy policy.

12-month warranty (new) · 3-month (used/refurbished)
30-day returns, no restocking fee on unused parts
Ships via

Quick facts

AvailabilityConfirmed on request
CategorySafety software for mobile machines
Warranty12-month (new) · 3-month (used/refurbished)

Shipping & availability

When can CP100S be shipped?

CP100S is sourced on request — request a quote and we'll confirm the exact availability and shipping timeline for this specific unit.

Can I pick up CP100S in person?

Local pickup from our Groningen, Netherlands warehouse may be possible — contact us before ordering to check availability and arrange a collection time.

Is express delivery available?

Yes — mention it when you request a quote for CP100S and we'll include express shipping options in our reply.

My factory is down and I need this urgently — can you help?

For a critical breakdown, contact us directly at +31 (0)50-7110348 or sales@partnerplc.com — we can look into same-day courier or dedicated taxi/hotshot delivery for CP100S, subject to availability and destination.

Programmable via CODESYS V3.5 CODESYS 3.5 safety libraries for mobile controllers from ifm

Specifications

Application

Applicationfor functionally safe applications with the ecomatBasic and the ecomatController
Functionsoftware package for programming in CODESYS 3.5 SP18
SoftwareCP100S
HardwareCR403S, CR413S; CR710S, CR711S; CR720S, CR721S

Inputs / outputs

Input functionsafety inputs; 64; Connection; IN00xx, IN01xx, IN02xx, IN03xx, IN04xx, IN05xx, IN06xx, IN07xx, IN08xx, IN09xx, IN10xx, IN11xx, IN12xx, IN13xx, IN14xx, IN15xx, IN16xx, IN17xx, IN18xx
Output functionsafety outputs; 68; Connection; OUT00xx, OUT01xx, OUT02xx, OUT03xx, OUT04xx, OUT05xx

Interfaces

ProtocolCANopen Safety; SAE J1939-76

Tests / approvals

EMCDIN EN 61326-3-1

Safety classification

Complies with the requirementsIEC 61508 SIL 2; ISO 26262 ASIL C
Mission time TM20 years
PFH [1/h]external one-channel input; 4.0E-09; external two-channel input; 5.0E-10; logic; 1,0E-07; external one-channel output; 2.0E-08; external two-channel output; 1.0E-09
Total Life Time20 Jahre
TTrip10 h
Typical use casePMFH: 48 Fit; this classification applies to the following assumption:; TLifetime (Total Operating Hours ) = 40000 h; (operating and non-operating phase of the device considered); (this is equivalent to operation for 20 years, 8 h a day on 250 days of the year or 10 h a day on 200 days)
Worst casePMFH: 73 Fit; this classification applies to the following assumption:; "always on"; (non-operating phase of the device not considered)

Remarks

Remarkscan be used in applications up to SIL 2 in accordance with IEC 62061; can be used in applications up to PL d in accordance with ISO 13849-1; can be used in applications up to AgPL d in accordance with ISO 25119; can be used in applications in accordance with DIN EN ISO 13766-2
12-month warrantyon all new stock
3-month warrantyon used & refurbished parts
30-day returnsno restocking fee on unused parts
Global shippingFast, tracked delivery worldwide

More IFM parts

IFM O8H205Available on requestIFM O8H205
MPN: O8H205 · IFM
Price on request
Request a quote
IFM O8H206Available on requestIFM O8H206
MPN: O8H206 · IFM
Price on request
Request a quote
IFM O8H207Available on requestIFM O8H207
MPN: O8H207 · IFM
Price on request
Request a quote
IFM O8H202Available on requestIFM O8H202
MPN: O8H202 · IFM
Price on request
Request a quote