Quick facts
| Availability | Confirmed on request |
| Category | Safe input/output modules |
| Warranty | 12-month (new) · 3-month (used/refurbished) |
Shipping & availability
When can AL200S be shipped?
AL200S is sourced on request — request a quote and we'll confirm the exact availability and shipping timeline for this specific unit.
Can I pick up AL200S in person?
Local pickup from our Groningen, Netherlands warehouse may be possible — contact us before ordering to check availability and arrange a collection time.
Is express delivery available?
Yes — mention it when you request a quote for AL200S and we'll include express shipping options in our reply.
My factory is down and I need this urgently — can you help?
For a critical breakdown, contact us directly at +31 (0)50-7110348 or sales@partnerplc.com — we can look into same-day courier or dedicated taxi/hotshot delivery for AL200S, subject to availability and destination.
Safe I/O module for PROFIsafe with safe inputs and outputs Connection of safe mechanical contacts and OSSD sensors possible PROFIsafe telegrams tunnelled via IO-Link Separate 24 V power supply of the outputs via standardised M12 L coding for high current rating Safety product in combination with IO-Link
Specifications
Application
| Design | only for operation with IO-Link masters AL140x, AL1304 to AL1307 and Siemens PLCs S7-1200 and S7-1500 (except software controller and open controller) |
| Application | I/O modules for field applications |
Electrical data
| Operating voltage[V] [V] | 19.2...30.2 DC; (US ; to SELV/PELV) |
| Current consumption[mA] [mA] | 67; (US) |
| Protection class | III |
| Additional voltage supply[V] [V] | 19.2...30.2 DC; (UA) |
| Max. current consumption from additional supply[mA] [mA] | 34; (UA) |
| Max. current load total[A] [A] | 6 |
| Current rating per port[A] [A] | 2 |
Inputs / outputs
| Total number of inputs and outputs | 12 |
Inputs
| Total number of inputs | 8 |
| Switching level high[V] [V] | 11...30 |
| Switching level low[V] [V] | -30...5 |
| Digital inputs protected against short circuits | yes |
Outputs
| Total number of outputs | 4 |
| Short-circuit proof | yes |
Interfaces
| Communication interface | IO-Link |
| Supported DeviceIDs | IO-Link Device; 1312 |
| IO-Link Device | 1312 |
| Transmission type | COM3 (230,4 kBaud) |
| IO-Link revision | 1.1 |
| SDCI standard | IEC 61131-9 |
| Profiles | Function; Extended identification |
| Function | Extended identification |
| SIO mode | no |
| Min. process cycle time[ms] [ms] | 4 |
Operating conditions
| Ambient temperature[°C] [°C] | -25...60 |
| Storage temperature[°C] [°C] | -40...85 |
| Max. relative air humidity[%] [%] | 75 |
| Protection | IP 65; IP 67 |
Tests / approvals
| EMC | EN 61000-6-2; EN 61000-4-2 ESD; 6 kV CD / 8 kV AD; EN 61000-4-3 HF radiated; 10 V/m; EN 61000-4-4 Burst; 2 kV; EN 61000-4-5 Surge; EN 61000-4-6 HF conducted |
| EN 61000-4-2 ESD | 6 kV CD / 8 kV AD |
| EN 61000-4-3 HF radiated | 10 V/m |
| EN 61000-4-4 Burst | 2 kV |
| Shock resistance | DIN EN 60068-2-27 |
| Vibration resistance | DIN EN 60068-2-64 2009-04; DIN EN 60068-2-6 2008-10 |
Safety classification
| Mission time TM[h] [h] | 175200 |
| Mission time TM (additional indication) | 20 years |
| Complies with the requirements | ISO 13849-1 PL e; IEC 61508 SIL 3; IEC 62061 SIL 3 |
| PFH[1/h] [1/h] | 1E-09 |
| PFD | 1E-05 |
Mechanical data
| Weight[g] [g] | 408.3 |
| Housing | rectangular |
| Type of mounting | backplane mounting |
| Dimensions[mm] [mm] | 214 x 59.8 x 30 |
| Materials | housing: PA; socket: brass nickel-plated |
Remarks
| Remarks | Safety classification depends on parameter setting and wiring (see operating instructions). |
| Pack quantity | 1 pcs. |
Electrical connection - Address Plug
| Connector | M12; coding: A |
Electrical connection - IO-Link
| Connector | M12; coding: A |
Electrical connection - Power IN
| Connector | M12; coding: L |
Electrical connection - Safety Inputs
| Connector | M12; coding: A |
Electrical connection - Safety Outputs
| Connector | M12; coding: A |