Honeywell AWD3B5W10MC3A00

SBC AWD3 Series 3-Phase Energy Meters with Transformer Connection

MPN
AWD3B5W10MC3A00
Price and lead time confirmed within 1 business day

Discontinued by Honeywell — we can still source the original AWD3B5W10MC3A00 (new, used or refurbished, subject to availability). Request a quote below.

Request a Quote

A real person replies, typically within 1 business day — see our privacy policy.

What happens next
  1. We check stock, condition and lead time
  2. You get a written quote by email
  3. Approve it and we ship — in-stock parts within 1 business day
  • 12-month warranty (new) · 3-month (used/refurbished)
  • 30-day returns, no restocking fee on unused parts
  • Ships via
  • 100% positive eBay feedback

Have spare Honeywell parts? We buy surplus →

What is the Honeywell AWD3B5W10MC3A00?

The Three-phase AWD3 energy meters are equipped with a transformer connection. By using a current transformer, you can replace defective energy meters and current transformers when the system is running, the energy meters are available in a one-way or two-way (bidirectional) design. Connect the energy meters to the Saia PCD family of devices via an integrated S-Bus, M-Bus or Modbus interface in order to read relevant data such as energy, current, voltage and power (active and reactive). Depending on the interface type, the energy meters are available in a one-way or two-way (bidirectional) design. AWD3 3-phase bidirectional energy meter for current converter metering with integrated S0-output Bidirectional energy meter with LC display and integrated S0-interface. The S0-interface is a hardware interface used in the transmission of measurements in building automation.

Features & Benefits:

3-phase energy meter, 3 × 230 / 400VAC 50Hz

Converter metering to 1500 A in both directions of current

Display of the active power, voltage and current per phase

Display of the total active power

S0-output; independent of the direction of current

7-digit display for energy supply and feeding back

Can be sealed and is provided with a sealing cap as an accessory

Certifications:

EN50470-3

IEC62053-21

EAC

Honeywell AWD3B5W10MC3A00 — The Three-phase AWD3 energy meters are equipped with a transformer connection. Can Replace defective energy meters and current transformers when the system is running and energy meters are available in a one-way or two-way design. Discontinued by Honeywell — no longer in the current range. PartnerPLC sources new, surplus and discontinued Honeywell parts — request a quote for price, condition and lead time.

Specifications

Product

LifecycleDiscontinued by Honeywell

Ordering codes

Part numbers on this product pageAWD3B5W10MC3A00, AWD3B5WS00C3A00, AWD3D5W10MC2C00, AWD3D5W10MC3A00, AWD3D5W10MC3C00, AWD3D5W10ND3A00, AWD3D5WD00C3A00, AWD3D5WD00C3A20, AWD3D5WD00C3A44, AWD3D5WD00C3C00, AWD3D5WM00C2A60, AWD3D5WM00C3A00, AWD3D5WM00C3A20, AWD3D5WM00C3C00, AWD3D5WM00D2A00, AWD3D5WS00C3A00

AWD3B5W10MC3A00: frequently asked questions

Can I still buy the AWD3B5W10MC3A00 now that it is discontinued?

Yes. Honeywell has discontinued the AWD3B5W10MC3A00, but sourcing discontinued parts is what PartnerPLC specialises in — new old stock, used and refurbished units. Request a quote and we'll confirm availability, condition and lead time.

When can AWD3B5W10MC3A00 be shipped?

AWD3B5W10MC3A00 is sourced on request — request a quote and we'll confirm the exact availability and shipping timeline for this specific unit.

Can I pick up AWD3B5W10MC3A00 in person?

Local pickup from our Groningen, Netherlands warehouse may be possible — contact us before ordering to check availability and arrange a collection time.

Is express delivery available?

Yes — mention it when you request a quote for AWD3B5W10MC3A00 and we'll include express shipping options in our reply.

My factory is down and I need this urgently — can you help?

For a critical breakdown, contact us directly at +31 (0)50-7110348 or sales@partnerplc.com — we can look into same-day courier or dedicated taxi/hotshot delivery for AWD3B5W10MC3A00, subject to availability and destination.

More Honeywell parts

Honeywell AW811 – V110 DN15 Q3:2,5 L165 NRV
Honeywell
AW811

V110 DN15 Q3:2,5 L165 NRV

Honeywell AW812 – V110 DN20 Q3:4 L165 NRV
Honeywell
AW812

V110 DN20 Q3:4 L165 NRV

Honeywell AW813 – V110 DN25 Q3:6,3 L199 NRV
Honeywell
AW813

V110 DN25 Q3:6,3 L199 NRV

Honeywell AW815 – 2,5 V110T NRV 'C' 114
Honeywell
AW815

2,5 V110T NRV 'C' 114

Honeywell AWM1200V – AWM 1000 Series airflow sensor, unamplified (mV), flowpressure range: ±10.0 mbar [4.0 H<sub>2<sub>O]; straight port style
Honeywell
AWM1200V

AWM 1000 Series airflow sensor, unamplified (mV), flowpressure range: ±10.0 mbar [4.0 H<sub>2<sub>O]; straight port style

Honeywell AWM1300V – AWM 1000 Series airflow sensor, unamplified (mV), flowpressure range: +1000 sccm (1.0 SLPM) to -600 sccm; straight port style
Honeywell
AWM1300V

AWM 1000 Series airflow sensor, unamplified (mV), flowpressure range: +1000 sccm (1.0 SLPM) to -600 sccm; straight port style

Honeywell AWM2100V – Airflow Sensor
Honeywell
AWM2100V

Airflow Sensor

Honeywell AWM2150V – AWM2000 Series airflow sensor, unamplified (mV), flowpressure range: ±30.0 sccm; straight port style
Honeywell
AWM2150V

AWM2000 Series airflow sensor, unamplified (mV), flowpressure range: ±30.0 sccm; straight port style

Honeywell AWD3B5W10MC3A00Price and lead time confirmed within 1 business day
Request a Quote