What is the Honeywell 809051.01?

The Compact is a powerful, professional 1-loop fire alarm control panel for monitoring small to medium sized premises with increased demands on reliability - redundancy through loop wiring. It allows simultaneous detection, control, and warning, both on the loop including spurs, as well as with the inputs and outputs built into the control panel, e.g., fire brigade interface, interface for fire control, outputs for onventional alarm devices and other relays for individual controls.

The fire brigade peripherals (FBF, FAT) or a repeater panel can be operated via the integrated RS485 interface.

The Compact is ideal for premises such as schools, kindergartens, nursing homes, doctors‘ offices, DIY markets, small hotels, shops, small businesses and manufacturing or retail.

Features & Benefits:

Single loop panel esserbus / esserbus-PLus

Short circuit and open circuit tolerant loop operation with spur cable exits

Operation of loop powered, synchronously activated alarm devices (optical/acoustic/voice) in different alarm zones via esserbus-PLus powered loop technology

Length of the loop circuit (esserbus) up to 3.5 km

Up to 127 esserbus devices (fire detectors or manual call points)/group

Up to 32 esserbus transponders

Up to 30 IQ8Quad detectors with integrated sounders

Up to 20 IQ8Alarm / IQ8Alarm Plus sounder

Operation of ATEX approved detectors (intrinsically safe) for potentially explosive areas

Optimized commissioning, maintenance and operation

Easy configuration and programming of the FACP functions via display

4 relays, programmable, not monitored, potential-free, max. 30 V DC/2 A or 60 V DC/1 A

2 outputs for connection to acoustic and optical sounders according to EN 54-13 (each 24 V DC/max. 500 mA)

1 interface for Fire alarm routing equipment (FARE) (12 V DC/max. 200 mA)

1 interface for fault routing equipment (12 V DC/max. 200 mA)

1 standard interface solution for fire control type C acc. DIN EN 54-2

RS485 for connection of fire brigade control panel and fire brigade graphic annunciator

1 output UBext 24 V/0.5 A, for the voltage supply of external devices

72 hour emergency bypass (depending on configuration)

Large LCD display with 8 rows x 40 characters

Integrated zonal indicator

Delay function (PM operating mode according to DIN VDE 0833-2 for preventing false alarms, delay / verify)

Co-incidence detection function (TM operating mode according to DIN VDE 0833-2 for preventing false alarms), alternatively programmable as alarm latching or 2-zone dependency between the detector zones

Alarm counter for up to 10,000 trips

Event memory for up to 10,000 events

Honeywell ESSER 809051.01 — 1-loop Fire Alarm Control Panel. Discontinued by Honeywell — no longer in the current range. PartnerPLC sources new, surplus and discontinued Honeywell parts — request a quote for price, condition and lead time.

Specifications

Product

LifecycleDiscontinued by Honeywell
Brand lineESSER

Others

BrandESSER

Ordering codes

Part numbers on this product page809051.01, 809051.02, 809051.08, 809051.08.DRAEGER, 809051.15, 809052.01, 809052.02, 809052.05, 809052.06, 809052.07, 809052.08

809051.01: frequently asked questions

Can I still buy the 809051.01 now that it is discontinued?

Yes. Honeywell has discontinued the 809051.01, but sourcing discontinued parts is what PartnerPLC specialises in — new old stock, used and refurbished units. Request a quote and we'll confirm availability, condition and lead time.

When can 809051.01 be shipped?

809051.01 is sourced on request — request a quote and we'll confirm the exact availability and shipping timeline for this specific unit.

Can I pick up 809051.01 in person?

Local pickup from our Groningen, Netherlands warehouse may be possible — contact us before ordering to check availability and arrange a collection time.

Is express delivery available?

Yes — mention it when you request a quote for 809051.01 and we'll include express shipping options in our reply.

My factory is down and I need this urgently — can you help?

For a critical breakdown, contact us directly at +31 (0)50-7110348 or sales@partnerplc.com — we can look into same-day courier or dedicated taxi/hotshot delivery for 809051.01, subject to availability and destination.

More Honeywell parts

Honeywell 809013 – ES COM C
Honeywell
809013

ES COM C

Honeywell 809021 – FACP ES Line
Honeywell
809021

FACP ES Line

Honeywell 809022 – Fire Safety Control Unit
Honeywell
809022

Fire Safety Control Unit

Honeywell 809041.08 – FACP ES- Detect Line
Honeywell
809041.08

FACP ES- Detect Line

Honeywell 80905F
Honeywell
80905F
Honeywell 80950F
Honeywell
80950F
Honeywell 8100 – Smoke Detector
Honeywell
8100

Smoke Detector

Honeywell 81007-801N – Printer / Serial Interface
Honeywell
81007-801N

Printer / Serial Interface

Honeywell 809051.01Price and lead time confirmed within 1 business day
Request a Quote