B&R X20SM1426

I/O module, 1 full bridge for controlling stepper motors

MPN
X20SM1426
Price and lead time confirmed within 1 business day
Request a Quote

A real person replies, typically within 1 business day — see our privacy policy.

  • 12-month warranty (new) · 3-month (used/refurbished)
  • 30-day returns, no restocking fee on unused parts
  • Ships via

What is the B&R X20SM1426?

1 stepper motor, 24 VDC, 1 A (1.2 A peak)

Resolution of current values at 1%

Maximum, rated and holding current configured independent of each other

38.5 kHz PWM frequency

Integrated motor detection

256 micro-steps

Stall detection

Complete integration in Automation Studio and CNC applications

4 inputs, 24 VDC, can be configured as ABR

Ramp function model based on the CANopen communication profile DS402

NetTime timestamp: Position change, trigger time

The stepper motor module is used to control stepper motors with a rated voltage of 24 VDC at a motor current up to 1 A (1.2 A peak). Additionally, this module has four digital inputs that can be used as limit switches or as encoder inputs.

Due to the individual adjustment of the coil currents, the motor is only operated with the current it actually needs. This simplifies the selection of the available motors and prevents unnecessary heating. Because this affects energy consumption and thermal load, the effects are positive on the service life of the complete system. Complete flexibility is achieved through the use of independently adjustable holding, maximum and nominal current values. The current for microsteps is automatically adjusted to the configured current values.

The automatic motor identification system is an enormous help during standstills. The stepper motor modules can identify the connected motors using their coil characteristics and generate feedback in the form of an analog value. This makes it possible to detect not only wiring errors, but also incorrect motor types being used mistakenly. "Stall detection" is integrated to analyze the motor load. Detection of the stall is defined via a configurable threshold. This allows an overload or motor standstill to be detected precisely in many different types of applications.

Specifications

Short description

I/O module1 full bridge for controlling stepper motors

General information

Diagnostics – Module run/errorYes, using LED status indicator and software
Diagnostics – OutputYes, using LED status indicator and software
Diagnostics – I/O power supplyYes, using software
Power consumption – Bus0.01 W
Power consumption – Internal I/O1.8 W
Certifications – CEYes
Certifications – UKCAYes
Certifications – CRA (Cyber Resilience Act)In preparation
Certifications – ATEXZone 2, II 3G Ex nA nC IIA T5 Gc; IP20, Ta (see X20 user's manual); FTZÚ 09 ATEX 0083X
Certifications – ULcURus E225616; Power conversion equipment
Certifications – HazLoccCSAus 244665; Process control equipment; for hazardous locations; Class I, Division 2, Groups ABCD, T5
Certifications – KCYes
B&R ID code0x2681
Status indicatorsI/O function per channel, operating state, module status
Additional power dissipation caused by actuators (resistive) [W]-

Motor output stage

Quantity1
Type2-phase bipolar stepper motor (full bridge)
Nominal voltage24 VDC -15% / +20%
Nominal current1 A
Maximum current1.2 A for 2 s (after a recovery time of at least 10 s at maximum 1 A)
Controller frequency38.4 kHz
DC bus capacitance57 µF
Step resolutionMax. 256 microsteps per step

Digital inputs

Input filter – Hardware<5 µs
Input filter – Software-
Switching threshold – Low<5 VDC
Switching threshold – High>15 VDC
Quantity4
Nominal voltage24 VDC -15% / +20%
Input circuitSink
Connection type1-wire connections
Input resistanceTyp. 18.2 kΩ
Additional functions1x ABR incremental encoder

ABR incremental encoder

Quantity1
Encoder inputs24 V, asymmetrical
Counter size16-bit
Input frequencyMax. 50 kHz
Evaluation4x

Electrical properties

Electrical isolationChannel isolated from bus; Channel not isolated from I/O power supply

Operating conditions

Mounting orientation – HorizontalYes
Installation elevation above sea level – 0 to 2000 mNo limitation
Installation elevation above sea level – >2000 mReduction of ambient temperature by 0.5°C per 100 m
Degree of protection per EN 60529IP20

Ambient conditions

Temperature – Horizontal mounting orientation-25 to 60°C (Rev. > E6), 0 to 55°C (Rev. ≤ E6)
Temperature – Vertical mounting orientationNot permitted
Temperature – Derating-
Temperature – Storage-25 to 70°C
Temperature – Transport-25 to 70°C
Relative humidity – Operation5 to 95%, non-condensing
Relative humidity – Storage5 to 95%, non-condensing
Relative humidity – Transport5 to 95%, non-condensing

Mechanical properties

NoteOrder 1x terminal block X20TB12 separately.; Order 1x bus module X20BM11 separately.
Pitch12.5 +0.2 mm

Accessories

Required accessories (order separately)

X20BM15Bus modules — The bus module is the base for all X20 24 VDC I/O modules; The internal I/O supply is interconnected; Manual node number assignment; Indepe…
X20BM11Bus modules — Bus module for 24 VDC I/O modules; The internal I/O power supply is connected through. The bus module is the base for all 24 VDC I/O module…
X20TB12Terminal blocks — Tool-free wiring with push-in technology; Simple wire release using lever; Ability to label each terminal; Plain text labeling also possibl…

X20SM1426: frequently asked questions

When can X20SM1426 be shipped?

X20SM1426 is sourced on request — request a quote and we'll confirm the exact availability and shipping timeline for this specific unit.

Can I pick up X20SM1426 in person?

Local pickup from our Groningen, Netherlands warehouse may be possible — contact us before ordering to check availability and arrange a collection time.

Is express delivery available?

Yes — mention it when you request a quote for X20SM1426 and we'll include express shipping options in our reply.

My factory is down and I need this urgently — can you help?

For a critical breakdown, contact us directly at +31 (0)50-7110348 or sales@partnerplc.com — we can look into same-day courier or dedicated taxi/hotshot delivery for X20SM1426, subject to availability and destination.

More B&R parts

B&R X20SLX811-1 – I/O module, 8 safe type A digital inputs, 4 pulse outputs
B&R
X20SLX811-1

I/O module, 8 safe type A digital inputs, 4 pulse outputs

B&R X20SLX842 – I/O module, 8 safe type A digital inputs, 4 pulse outputs
B&R
X20SLX842

I/O module, 8 safe type A digital inputs, 4 pulse outputs

B&R X20SLX842-1 – I/O module, 8 safe type A digital inputs, 4 pulse outputs
B&R
X20SLX842-1

I/O module, 8 safe type A digital inputs, 4 pulse outputs

B&R X20SLX910 – I/O module, 20 safe type A digital inputs, 4 pulse outputs
B&R
X20SLX910

I/O module, 20 safe type A digital inputs, 4 pulse outputs

B&R X20SM1436 – I/O module, 1 full bridge for controlling stepper motors
B&R
X20SM1436

I/O module, 1 full bridge for controlling stepper motors

B&R X20SM1436-1 – I/O module, 1 full bridge for controlling stepper motors
B&R
X20SM1436-1

I/O module, 1 full bridge for controlling stepper motors

B&R X20SM1444-1 – I/O module, 1 full bridge for controlling stepper motors
B&R
X20SM1444-1

I/O module, 1 full bridge for controlling stepper motors

B&R X20SM1446-1 – I/O module, 1 full bridge for controlling stepper motors
B&R
X20SM1446-1

I/O module, 1 full bridge for controlling stepper motors

B&R X20SM1426Price and lead time confirmed within 1 business day
Request a Quote