B&R X20AI2437 – I/O module, 2 analog inputs 4 to 20 mA or 0 to 25 mA
Request a Quote
Quick facts
| Availability | Confirmed on request |
| Category | Analog inputs |
| Lifecycle | Active |
| Warranty | 12-month (new) · 3-month (used/refurbished) |
| Datasheet | Manufacturer datasheet ↗ |
Shipping & availability
When can X20AI2437 be shipped?
X20AI2437 is sourced on request — request a quote and we'll confirm the exact availability and shipping timeline for this specific unit.
Can I pick up X20AI2437 in person?
Local pickup from our Groningen, Netherlands warehouse may be possible — contact us before ordering to check availability and arrange a collection time.
Is express delivery available?
Yes — mention it when you request a quote for X20AI2437 and we'll include express shipping options in our reply.
My factory is down and I need this urgently — can you help?
For a critical breakdown, contact us directly at +31 (0)50-7110348 or sales@partnerplc.com — we can look into same-day courier or dedicated taxi/hotshot delivery for X20AI2437, subject to availability and destination.
• 2 analog current measurement inputs
• Electrically isolated analog channels
• Electrically isolated sensor supplies
• 16-bit digital converter resolution
• NetTime timestamp: Moment of measurement
The module is equipped with 2 current measurement inputs with 16-bit digital converter resolution.
Each current measurement input has its own sensor supply. The two channels with their respective sensor supplies are electrically isolated from each other. The user can select between the two measurement ranges 4 to 20 mA and 0 to 25 mA .
Accessories
Required accessories (order separately)
| X20BM15 | Bus modules — The bus module is the base for all X20 24 VDC I/O modules; The internal I/O supply is interconnected; Manual node number assignment; Indepe… |
| X20BM11 | Bus modules — Bus module for 24 VDC I/O modules; The internal I/O power supply is connected through. The bus module is the base for all 24 VDC I/O module… |
| X20TB12 | Terminal blocks — Tool-free wiring with push-in technology; Simple wire release using lever; Ability to label each terminal; Plain text labeling also possibl… |
Specifications
Short description
| I/O module | 2 analog inputs 4 to 20 mA or 0 to 25 mA |
General information
| Diagnostics – Module run/error | Yes, using LED status indicator and software |
| Diagnostics – Inputs | Yes, using LED status indicator and software |
| Diagnostics – Sensor power supply | Yes, using LED status indicator and software |
| Power consumption – Bus | 0.05 W |
| Power consumption – Internal I/O | 1.15 W " data-placement="top" data-html="true" data-container="body" data-content="To reduce power dissipation, B&R recommends leaving unused inputs open."> |
| Certifications – CE | Yes |
| Certifications – UKCA | Yes |
| Certifications – CRA (Cyber Resilience Act) | In preparation |
| Certifications – ATEX | Zone 2, II 3G Ex nA nC IIA T5 Gc; IP20, Ta (see X20 user's manual); FTZÚ 09 ATEX 0083X |
| Certifications – UL | cULus E115267; Industrial control equipment |
| Certifications – HazLoc | cCSAus 244665; Process control equipment; for hazardous locations; Class I, Division 2, Groups ABCD, T5 |
| Certifications – DNV | Temperature: B (0 to 55°C); Humidity: B (up to 100%); Vibration: B (4 g); EMC: B (bridge and open deck) |
| Certifications – CCS | Yes |
| Certifications – LR | ENV1 |
| Certifications – KR | Yes |
| Certifications – ABS | Yes |
| Certifications – BV | EC33B ; Temperature: 5 - 55°C; Vibration: 4 g; EMC: Bridge and open deck |
| Certifications – KC | Yes |
| B&R ID code | 0xB784 |
| Status indicators | I/O function per channel, operating state, module status, sensor power supply per channel |
| Additional power dissipation caused by actuators (resistive) [W] | - |
Analog inputs
| Output format – 4 to 20 mA | INT 0x0000 - 0x7FFF / 1 LSB = 0x0001 = 488.281 nA |
| Output format – 0 to 25 mA | INT 0x0000 - 0x7FFF / 1 LSB = 0x0001 = 762.939 nA |
| Output format – 0 to 25000 µA | INT 0x0000 - 0x61A8 / 1 LSB = 0x0001 = 1000 nA |
| Max. error – 0 to 25 mA | <0.046% " data-placement="top" data-html="true" data-container="body" data-content="Based on the current measured value."> |
| Max. error – 4 to 20 mA | <0.046% " data-placement="top" data-html="true" data-container="body" data-content="Based on the current measured value."> |
| Max. error – 0 to 25 mA | <0.004% " data-placement="top" data-html="true" data-container="body" data-content="Based on the 25 mA measurement range."> |
| Max. error – 4 to 20 mA | <0.013% " data-placement="top" data-html="true" data-container="body" data-content="Based on the 25 mA measurement range."> |
| Common-mode rejection – DC | 80 dB |
| Common-mode rejection – 50 Hz | Depends on the sampling rate: e.g. >130 dB for 50 samples per second |
| Input filter – Hardware | First-order low-pass filter / cutoff frequency 2.5 kHz |
| Input filter – Software | Sinc 4 filter |
| Max. gain drift – 0 to 25 mA | 0.003 %/°C " data-placement="top" data-html="true" data-container="body" data-content="Based on the current measured value."> |
| Max. gain drift – 4 to 20 mA | 0.003 %/°C " data-placement="top" data-html="true" data-container="body" data-content="Based on the current measured value."> |
| Max. offset drift – 0 to 25 mA | 0.0002 %/°C " data-placement="top" data-html="true" data-container="body" data-content="Based on the 25 mA measurement range."> |
| Max. offset drift – 4 to 20 mA | 0.0007 %/°C " data-placement="top" data-html="true" data-container="body" data-content="Based on the 25 mA measurement range."> |
| Test voltage – Channel - Channel | 1000 VAC |
| Test voltage – Channel - Bus | 1000 VAC |
| Test voltage – Channel - Ground | 1000 VAC |
| Input | 4 to 20 mA or 0 to 25 mA configurable using software |
| Input type | Differential input |
| Digital converter resolution | 16-bit |
| Data output rate | 4.7 to 960 samples per second, configurable using software |
| Output format | INT |
| Load | I_IN ≥ 0.1 mA: R < 8000 Ω ; I_IN ≥ 1 mA: R < 1100 Ω ; I_IN ≥ 4 mA: R < 510 Ω |
| Input protection | Up to 30 VDC, reverse polarity protection (max. 0.1 A) |
| Open-circuit detection | Yes, using software |
| Permissible input signal | 0 to 25 mA |
| Output of digital value during overload | Configurable |
| Conversion procedure | Sigma-delta |
| Common-mode range | 0 to 7 V |
| Nonlinearity | <0.003% " data-placement="top" data-html="true" data-container="body" data-content="Based on the 25 mA measurement range."> |
Sensor power supply
| Max. voltage ripple – Up to 100 kHz | ≤2.2 mV |
| Max. voltage ripple – Up to 1 MHz | ≤22 mV |
| Max. voltage ripple – Higher | ≤100 mV |
| Short-circuit current – Typical | <50 mA |
| Short-circuit current – Maximum | 60 mA |
| Power consumption | 0.75 W per channel |
| Nominal voltage | 25 V ±2% |
| Nominal output current | Max. 30 mA |
| Short-circuit proof | Yes, continuous |
| Behavior on short circuit | Current limiting |
Electrical properties
| Electrical isolation | Channel isolated from channel and bus; Sensor power supply isolated from sensor power supply; Sensor power supply not isolated from channel |
Operating conditions
| Mounting orientation – Horizontal | Yes |
| Mounting orientation – Vertical | Yes |
| Installation elevation above sea level – 0 to 2000 m | No limitation |
| Installation elevation above sea level – >2000 m | Reduction of ambient temperature by 0.5°C per 100 m |
| Degree of protection per EN 60529 | IP20 |
Ambient conditions
| Temperature – Horizontal mounting orientation | -25 to 60°C |
| Temperature – Vertical mounting orientation | -25 to 50°C |
| Temperature – Derating | - |
| Temperature – Storage | -40 to 85°C |
| Temperature – Transport | -40 to 85°C |
| Relative humidity – Operation | 5 to 95%, non-condensing |
| Relative humidity – Storage | 5 to 95%, non-condensing |
| Relative humidity – Transport | 5 to 95%, non-condensing |
Mechanical properties
| Note | Order 1x terminal block X20TB12 separately. ; Order 1x bus module X20BM11 separately. |
| Pitch | 12.5 +0.2 mm |
Downloads & documentation
Official documents from B&R, downloaded directly from the manufacturer.
Data sheets & manuals
| Data sheet X20AI2437 | PDF · 906 KB · 1.40 (07/31/2025) - EN |
| X20 Package leaflet ATEX/CSA | PDF · 2 MB · 1.4 (09/17/2024) |
| X20 System User´s Manual | PDF · 50 MB · 4.40 (03/10/2026) - EN |
CAD & dimension drawings
| 3D File DXF/STEP X20 Electronic module | ZIP · 10 KB · 1.0 (10/17/2005) |
| 3D File STEP X20 I/O-Slice | ZIP · 872 KB · 1.1 (03/13/2019) |
| Dimensions PDF X20 Electronic module | PDF · 3 KB · 1.0 (10/17/2005) |
Certificates (15)
More B&R parts
Available on requestB&R X20AI1744-3 – I/O module, 1 full-bridge strain gauge input
Available on requestB&R X20AI2222 – I/O module, 2 analog inputs ±10 V
Available on requestB&R X20AI2237 – I/O module, 2 analog inputs ±10 V
Available on requestB&R X20AI2322 – I/O module, 2 analog inputs 0 to 20 mA / 4 to 20 mA
Available on requestB&R X20AI2438 – I/O module, 2 analog inputs 4 to 20 mA or 0 to 25 mA
Available on requestB&R X20AI2622 – I/O module, 2 analog inputs ±10 V or 0 to 20 mA / 4 to 20 mA
Available on requestB&R X20AI2632 – I/O module, 2 analog inputs ±10 V or 0 to 20 mA
Available on requestB&R X20AI2632-1 – I/O module, 2 analog inputs ±11 V or 0 to 22 mA