Available on request

B&R X20AI1744 – I/O module, 1 full-bridge strain gauge input

MPN: X20AI1744 · Brand: B&R
Price on request
Request a Quote

A real person replies, typically within 1 business day — see our privacy policy.

12-month warranty (new) · 3-month (used/refurbished)
30-day returns, no restocking fee on unused parts
Ships via

Quick facts

AvailabilityConfirmed on request
CategoryAnalog inputs
LifecycleActive
Warranty12-month (new) · 3-month (used/refurbished)
DatasheetManufacturer datasheet ↗

Shipping & availability

When can X20AI1744 be shipped?

X20AI1744 is sourced on request — request a quote and we'll confirm the exact availability and shipping timeline for this specific unit.

Can I pick up X20AI1744 in person?

Local pickup from our Groningen, Netherlands warehouse may be possible — contact us before ordering to check availability and arrange a collection time.

Is express delivery available?

Yes — mention it when you request a quote for X20AI1744 and we'll include express shipping options in our reply.

My factory is down and I need this urgently — can you help?

For a critical breakdown, contact us directly at +31 (0)50-7110348 or sales@partnerplc.com — we can look into same-day courier or dedicated taxi/hotshot delivery for X20AI1744, subject to availability and destination.

• 1 full-bridge strain gauge input

• Data output rate configurable from 0.1 Hz to 7.5 kHz

• Special operating modes (synchronous mode and multiple sampling)

• Configurable filter level

This module works with both 4-wire and 6-wire strain gauge load cells. The concept applied by the module requires compensation in the measurement system. This compensation eliminates the absolute uncertainty in the measurement circuit, such as component tolerances, effective bridge voltage or zero point offset. The measurement precision refers to the absolute (compensated) value, which will only change as a result of changes in the operating temperature.

Accessories

Required accessories (order separately)

X20BM15Bus modules — The bus module is the base for all X20 24 VDC I/O modules; The internal I/O supply is interconnected; Manual node number assignment; Indepe…
X20BM11Bus modules — Bus module for 24 VDC I/O modules; The internal I/O power supply is connected through. The bus module is the base for all 24 VDC I/O module…
X20TB12Terminal blocks — Tool-free wiring with push-in technology; Simple wire release using lever; Ability to label each terminal; Plain text labeling also possibl…

Specifications

Short description

I/O module1 full-bridge strain gauge input

General information

Diagnostics – Module run/errorYes, using LED status indicator and software
Diagnostics – Open circuitYes, using LED status indicator and software
Diagnostics – InputYes, using LED status indicator and software
Power consumption – Bus0.01 W
Power consumption – Internal I/O0.5 W
Certifications – CEYes
Certifications – UKCAYes
Certifications – CRA (Cyber Resilience Act)In preparation
Certifications – ATEXZone 2, II 3G Ex nA nC IIA T5 Gc; IP20, Ta (see X20 user's manual); FTZÚ 09 ATEX 0083X
Certifications – ULcULus E115267; Industrial control equipment
Certifications – HazLoccCSAus 244665; Process control equipment; for hazardous locations; Class I, Division 2, Groups ABCD, T5
Certifications – KCYes
B&R ID code0x1CDE
Status indicatorsChannel status, operating state, module status
Additional power dissipation caused by actuators (resistive) [W]Max. +0.36 " data-placement="top" data-html="true" data-container="body" data-content="Depends on the full-bridge strain gauge being used.">

Full-bridge strain gauge

Input filter – Cutoff frequency5 kHz
Input filter – Order3
Input filter – Slope60 dB
Output of digital value – Broken bridge supply lineValue approaching 0
Output of digital value – Broken sensor lineValue approaching ±end value (status bit "Line monitoring" is set in register "Module status")
Output of digital value – Valid range of values0xFF800001 to 0x007FFFFF (-8,388,607 to 8,388,607)
Strain gauge supply – Voltage5.5 VDC / Max. 65 mA
Strain gauge supply – Short-circuit and overload-proofYes
Strain gauge supply – Voltage drop for short-circuit protectionMax. 0.2 VDC at 65 mA and 25°C
Quantization " data-placement="top" data-html="true" data-container="body" data-content="Quantization depends on the strain gauge factor."> – 2 mV/V336 nV
Quantization " data-placement="top" data-html="true" data-container="body" data-content="Quantization depends on the strain gauge factor."> – 4 mV/V671 nV
Quantization " data-placement="top" data-html="true" data-container="body" data-content="Quantization depends on the strain gauge factor."> – 8 mV/V1.343 µV
Quantization " data-placement="top" data-html="true" data-container="body" data-content="Quantization depends on the strain gauge factor."> – 16 mV/V2.686 µV
Quantization " data-placement="top" data-html="true" data-container="body" data-content="Quantization depends on the strain gauge factor."> – 32 mV/V5.371 μV
Quantization " data-placement="top" data-html="true" data-container="body" data-content="Quantization depends on the strain gauge factor."> – 64 mV/V10.74 μV
Quantization " data-placement="top" data-html="true" data-container="body" data-content="Quantization depends on the strain gauge factor."> – 128 mV/V21.48 μV
Quantization " data-placement="top" data-html="true" data-container="body" data-content="Quantization depends on the strain gauge factor."> – 256 mV/V42.97 μV
Quantization " data-placement="top" data-html="true" data-container="body" data-content="Quantization depends on the strain gauge factor."> – 2 mV/V1.31 nV
Quantization " data-placement="top" data-html="true" data-container="body" data-content="Quantization depends on the strain gauge factor."> – 4 mV/V2.62 nV
Quantization " data-placement="top" data-html="true" data-container="body" data-content="Quantization depends on the strain gauge factor."> – 8 mV/V5.25 nV
Quantization " data-placement="top" data-html="true" data-container="body" data-content="Quantization depends on the strain gauge factor."> – 16 mV/V10.49 nV
Quantization " data-placement="top" data-html="true" data-container="body" data-content="Quantization depends on the strain gauge factor."> – 32 mV/V20.98 nV
Quantization " data-placement="top" data-html="true" data-container="body" data-content="Quantization depends on the strain gauge factor."> – 64 mV/V41.96 nV
Quantization " data-placement="top" data-html="true" data-container="body" data-content="Quantization depends on the strain gauge factor."> – 128 mV/V83.92 nV
Quantization " data-placement="top" data-html="true" data-container="body" data-content="Quantization depends on the strain gauge factor."> – 256 mV/V167.85 nV
Strain gauge factor2 to 256 mV/V, configurable using software
Connection4- or 6-wire connections " data-placement="top" data-html="true" data-container="body" data-content="With 6-wire connections, line compensation does not function (see section "Connection examples").">
Input typeDifferential, used to evaluate a full-bridge strain gauge
Digital converter resolution24-bit
Conversion timeDepends on the configured data output rate
Data output rate0.1 - 7500 samples per second, configurable using software (f DATA )
ADC filter characteristicsSigma-delta, see section "Filter characteristics of the sigma-delta A/D converter"
Operating range / Measurement sensor85 to 5000 Ω
Influence of cable length " data-placement="top" data-html="true" data-container="body" data-content="Sensor cable with twisted and shielded conductors, cable length as short as possible, cable routing separate from load circuits, without intermediate terminal to the sensor.">See section "Calculation example".
Input protectionRC protection
Common-mode range0 to 3 VDC ; Permissible input voltage range (with regard to the electric potential strain gauge GND) on inputs "Input +" and "Input -"
Insulation voltage between input and bus500 V eff
Conversion procedureSigma-delta
Max. gain drift12 ppm/°C " data-placement="top" data-html="true" data-container="body" data-content="Based on the current measured value.">
Max. offset drift2 ppm/°C " data-placement="top" data-html="true" data-container="body" data-content="Based on the entire measurement range.">
Nonlinearity<10 ppm " data-placement="top" data-html="true" data-container="body" data-content="Based on the entire measurement range.">

Electrical properties

Electrical isolationBus isolated from analog input and strain gauge supply voltage; Channel not isolated from I/O power supply

Operating conditions

Mounting orientation – HorizontalYes
Mounting orientation – VerticalYes
Installation elevation above sea level – 0 to 2000 mNo limitation
Installation elevation above sea level – >2000 mReduction of ambient temperature by 0.5°C per 100 m
Degree of protection per EN 60529IP20

Ambient conditions

Temperature – Horizontal mounting orientation-25 to 60°C
Temperature – Vertical mounting orientation-25 to 50°C
Temperature – DeratingSee section "Hardware configuration"
Temperature – Storage-40 to 85°C
Temperature – Transport-40 to 85°C
Relative humidity – Operation5 to 95%, non-condensing
Relative humidity – Storage5 to 95%, non-condensing
Relative humidity – Transport5 to 95%, non-condensing

Mechanical properties

NoteOrder 1x terminal block X20TB12 separately.; Order 1x bus module X20BM11 separately.
Pitch12.5 +0.2 mm

Downloads & documentation

Official documents from B&R, downloaded directly from the manufacturer.

Data sheets & manuals

Data sheet X20AI1744PDF · 2 MB · 4.40 (07/31/2025) - EN
X20 Package leaflet ATEX/CSAPDF · 2 MB · 1.4 (09/17/2024)
X20 System User´s ManualPDF · 50 MB · 4.40 (03/10/2026) - EN

CAD & dimension drawings

3D File DXF/STEP X20 Electronic moduleZIP · 10 KB · 1.0 (10/17/2005)
3D File STEP X20 I/O-SliceZIP · 872 KB · 1.1 (03/13/2019)
Dimensions PDF X20 Electronic modulePDF · 3 KB · 1.0 (10/17/2005)
Certificates (7)
E115267 UL Certificate of Compliance X20PDF · 3 MB · 2026_08_27 (08/27/2026)
EU Data Act - X20 IO - Connected Product Information NoticePDF · 92 KB · 1.00 (09/30/2025)
EU Declaration ATEX X20PDF · 218 KB · 2023-07 (09/05/2023)
EU Declaration of conformity PLC X20PDF · 169 KB · 2021/10 (11/08/2021)
FTZU 09 ATEX 0083XPDF · 771 KB · 3.00 (10/12/2021)
UK Declaration PLC X20PDF · 151 KB · 2024-01 (01/18/2024)
X20, X67 KC certificatesPDF · 7 MB · 2.00 (08/17/2026)
12-month warrantyon all new stock
3-month warrantyon used & refurbished parts
30-day returnsno restocking fee on unused parts
Global shippingFast, tracked delivery worldwide

More B&R parts

B&R X20AC0SL1.0010 – X20 end cover plate, left, package of 10 pcs.Available on requestB&R X20AC0SL1.0010 – X20 end cover plate, left, package of 10 pcs.
MPN: X20AC0SL1.0010 · B&R
Price on request
Request a quote
B&R X20AC0SR1 – X20 end cover plate, rightAvailable on requestB&R X20AC0SR1 – X20 end cover plate, right
MPN: X20AC0SR1 · B&R
Price on request
Request a quote
B&R X20AC0SR1.0010 – X20 end cover plate, right, package of 10 pcs.Available on requestB&R X20AC0SR1.0010 – X20 end cover plate, right, package of 10 pcs.
MPN: X20AC0SR1.0010 · B&R
Price on request
Request a quote
B&R X20AI1744-10 – I/O module, 1 full-bridge strain gauge inputAvailable on requestB&R X20AI1744-10 – I/O module, 1 full-bridge strain gauge input
MPN: X20AI1744-10 · B&R
Price on request
Request a quote
B&R X20AI1744-3 – I/O module, 1 full-bridge strain gauge inputAvailable on requestB&R X20AI1744-3 – I/O module, 1 full-bridge strain gauge input
MPN: X20AI1744-3 · B&R
Price on request
Request a quote
B&R X20AI2222 – I/O module, 2 analog inputs ±10 VAvailable on requestB&R X20AI2222 – I/O module, 2 analog inputs ±10 V
MPN: X20AI2222 · B&R
Price on request
Request a quote
B&R X20AI2237 – I/O module, 2 analog inputs ±10 VAvailable on requestB&R X20AI2237 – I/O module, 2 analog inputs ±10 V
MPN: X20AI2237 · B&R
Price on request
Request a quote