B&R 8I77T400400.0P-000 – ACOPOSinverter P77, 3x 340-528 V; 4 kW (heavy duty)
Request a Quote
Quick facts
| Availability | Confirmed on request |
| Category | ACOPOSinverter P77 - 3-phase 340 to 528 V |
| Lifecycle | Active |
| Warranty | 12-month (new) · 3-month (used/refurbished) |
| Weight | 1.35 kg |
Shipping & availability
When can 8I77T400400.0P-000 be shipped?
8I77T400400.0P-000 is sourced on request — request a quote and we'll confirm the exact availability and shipping timeline for this specific unit.
Can I pick up 8I77T400400.0P-000 in person?
Local pickup from our Groningen, Netherlands warehouse may be possible — contact us before ordering to check availability and arrange a collection time.
Is express delivery available?
Yes — mention it when you request a quote for 8I77T400400.0P-000 and we'll include express shipping options in our reply.
My factory is down and I need this urgently — can you help?
For a critical breakdown, contact us directly at +31 (0)50-7110348 or sales@partnerplc.com — we can look into same-day courier or dedicated taxi/hotshot delivery for 8I77T400400.0P-000, subject to availability and destination.
ACOPOSinverter P77, 3x 340-528 V; 4 kW (heavy duty), 11.9 A (@4kHz), integrated brake chopper, HTL encoder input onboard, 2-channel STO (SIL 3, PL e), POWERLINK hub with 2x RJ45, physical node number switches, shield plate included in delivery
Accessories
Optional accessories (11)
| 8I0BR180.060-1 | Braking resistors — ACPi P77 braking resistor 180 Ω 60 W |
| 8I0BR047.800-1 | Braking resistors — ACPi P77 braking resistor 47 Ω 800 W |
| 8I0BR047.400-1 | Braking resistors — ACPi P77 braking resistor 47 Ω 400 W |
| 8I0BR047.135-1 | Braking resistors — ACPi P77 braking resistor 47 Ω 135 W |
| 8I0XD070.402-1 | Front covers — ACPi USB module - Blue "Standard line" (VPE 1) - Compatible with ACOPOSinverter P77 |
| 8I0XD070.400-1 | Front covers — ACPi service display - Black "Standard line" (VPE 1) - Compatible with ACOPOSinverter P77 |
| 8I0FT014.57S-1 | Input filters — ACPi short distance filter 3-ph 14 A |
| 8I0FT014.57L-1 | Input filters — ACPi long distance filter 3-ph 14 A |
| 8I0CT016.570-1 | Line choke — ACPi mains choke 3-ph 16 A |
| 8I0CT010.570-1 | Line choke — ACPi mains choke 3-ph 10 A |
| 8I0CT008.570-1 | Line choke — ACPi mains choke 3-ph 8 A |
Specifications
General information
| Certifications – CE | Yes |
| Certifications – UKCA | Yes |
| Certifications – UL | cULus E225616; Power conversion equipment |
Motor power
| Specified on nameplate | 4 kW (5 HP) |
Mains connection
| Mains current – At 400 VAC | 12.5 A |
| Mains current – At 480 VAC | 12.5 A |
| Mains input voltage | 3x 340 VAC -15% to 528 VAC +10% |
| Frequency | 45 to 65 Hz ±5% |
| Apparent power (at 400 VAC) | 6.4 kVA |
| Max. assumed short-circuit current (Isc); (short-circuit current at connection point) | 65 kA " data-placement="top" data-html="true" data-container="body" data-content="With mains choke max. Isc 65 kA for 340-528 V."> |
| Power dissipation at nominal load and nominal clock frequency | 110 W |
| Integrated EMC filter | Yes " data-placement="top" data-html="true" data-container="body" data-content="Inverter is provided with an integrated Category C2 EMC filter. This filter can be switched off."> |
Line-conducted and radiated emissions
| With integrated filter – Motor cable length per IEC/EN 61800-3 ; Cat. C1 environment 1 (public power network) | C1 level of 4 to 16 kHz with 3 m cable |
| With integrated filter – Motor cable length per IEC/EN 61800-3 ; Cat. C2 environment 1 (public power network) | C2 level of 4 to 16 kHz with 20 m cable |
| With add-on filter – Motor cable length per IEC/EN 61800-3 ; Cat. C1 environment 1 (public power network) | C1 level of 4 to 8 kHz with 50 m cable |
| With add-on filter – Motor cable length per IEC/EN 61800-3 ; Cat. C2 environment 1 (public power network) | C2 level of 4 to 8 kHz with 100 m cable " data-placement="top" data-html="true" data-container="body" data-content="The selection table for the filters specifies maximum length for the shielded cables between motors and inverters. These maximum cable lengths only serve as a reference point since they depend on the capacity of the motors and the cables being used. The total length must be taken into account when motors are connected in parallel. These values apply at a nominal clock frequency of 4 kHz."> |
Motor connection
| Derating of continuous output current depending on ambient temperature – At nominal clock frequency (4 kHz) | No derating (up to 50°C) |
| Derating of continuous output current depending on ambient temperature – Other clock frequencies | The derating curves are included in the installation instructions, which can be downloaded from www.br-automation.com. |
| Derating of continuous output current depending on installation elevation – Starting at 1000 m above sea level | 1%, per 100 m |
| Clock frequency – Min. | 2 kHz |
| Clock frequency – Max. | 16 kHz |
| Max. motor cable length – Shielded cable | 50 m |
| Max. motor cable length – Non-shielded cable | 100 m |
| Motor control profiles – Induction motor | Sensorless vector control: ; 1. Voltage controlled with constant torque → standard mode ; Sensorless slip control: ; 1. With V/f characteristic curve for constant torque → Standard mode ; 2. With V/f characteristic curve for constant torque (6 f-ranges) → Custom mode for special applications ; 3. With V/f characteristic curve for quadratically increasing torque → Energy-saving profile, e.g. for fans and pumps |
| Motor control profiles – Synchronous motor | Sensorless vector control: ; 1. Voltage controlled with constant torque → standard mode |
| Nominal output current | 9.5 A " data-placement="top" data-html="true" data-container="body" data-content="These values apply at a nominal clock frequency of 4 kHz during continuous operation. The clock frequency can be set from 2 to 16 kHz. Above 4 kHz, reduce the nominal drive current. The nominal motor current is not permitted to exceed this value."> |
| Max. transient current for 15 s, 3-phase " data-placement="top" data-html="true" data-container="body" data-content="The inverter is designed for heavy-duty operation for a maximum of 15 seconds at 200% nominal current. For the values for light duty, see the configuration manual."> | 318 A |
| Output frequency range | 0.1 to 599 Hz |
| Nominal clock frequency | 4 kHz |
| Main protective functions of inverter | Thermal protection against power stage overheating Protection against: Short circuits between motor phases, overcurrent between output phases and ground, overvoltages on the DC bus, exceeding the speed limit. Safety function for: Overvoltage and undervoltage of the mains supply, mains phase failure with 3-phase power supply |
Brake chopper
| Integrated dynamic brake transistors | Yes |
| Min. resistance value (external) | 47 Ω |
| Max. output current | 15.4 A |
24 VDC power supply
| Input voltage | 24 VDC (-15%/+20%) |
| Current | Max. 1.1 A |
Available internal power supplies
| Output voltage 24 VDC – Max. output current at 24 VDC | 100 mA |
| Output voltage 10 VDC – Max. output current at 10 VDC | 10 mA |
| Output voltage 24 VDC | 24 VDC (-15%/+20%) |
| Output voltage 10 VDC | 10 VDC (-0%/+10%) |
Interfaces
| POWERLINK – Type | Type 3 " data-placement="top" data-html="true" data-container="body" data-content="For additional information, see section "Communication / POWERLINK / General information / Hardware - CN" in Automation Help."> |
Digital inputs
| Quantity | 5 |
| Nominal voltage | 24 VDC (max. 30 VDC) |
| Input circuit | Source or sink |
| Sampling time | 8 ms ±0.7 ms |
Safe input - STO (Safe Torque Off)
| Input impedance – Current consumption | 16 mA |
| Electrical isolation – Input - ACOPOSinverter | Yes |
| Quantity | 2 |
| Nominal voltage | 24 VDC (max. 30 VDC) |
| Input impedance | 1.5 kΩ |
Analog inputs
| Electrical isolation – Input - Input | No |
| Electrical isolation – Input - ACOPOSinverter | Yes |
| Input – Voltage | AI1: 0 to 10 VDC |
| Input – Current | 0 to 20 mA (or 4 to 20 mA) |
| Input impedance – Voltage | 70 kΩ |
| Input impedance – Current | <250 Ω |
| Quantity | 2 |
| Basic accuracy | ±0.1 mA or 50 mV |
| Resolution | 12-bit |
| Sampling time | 1 ms |
Digital outputs
| Quantity | 1 |
| Nominal voltage | 24 VDC -20%/+20% |
| Max. voltage | 30 VDC |
| Output circuit | Source or sink |
| Sampling time | 1 ms |
| Max. current | 100 mA |
Relay outputs
| Variant – Relay 1 | 1 changeover contact |
| Quantity | 1 |
| Nominal voltage | 24 VDC / 240 VAC |
| Switching current range | Min. switching current: 5 mA at 24 VDC ; Max. switching current: ; AC 240 V - 3 A ; DC 24 V - 2 A ; DC 240 V - 0.16 A |
Analog outputs
| Electrical isolation – Output - ACOPOSinverter | Yes |
| Electrical isolation – Output - Output | No |
| Max. load impedance – Voltage | ≥2200 Ω |
| Max. load impedance – Current | ≥2200 Ω |
| Quantity | 1 |
| Output | 0 to 10 V or 0 to 20 mA |
| Basic accuracy | ±100 mV or ±0.3 m |
| Resolution | 12-bit |
Electrical properties
| Energy efficiency (IE classification) – Power dissipation relative to continuous apparent power | IE2 (0, 25): 1.2% ; IE2 (0, 50): 1.3% ; IE2 (0, 100): 1.7% ; IE2 (50, 25): 1.2% ; IE2 (50, 50): 1.4% ; IE2 (50, 100): 1.9% ; IE2 (90, 50): 1.5% ; IE2 (90, 100): 2.0% |
| Energy efficiency (IE classification) – Nominal losses in standby mode | 0.1% |
Operating conditions
| Degree of protection per EN 61800-5-1 | IP20 |
| Relative humidity per IEC 60068-2-3 | <95%, non-condensing No dripping water |
| Maximum installation elevation | ≤1000 m without derating ; 1000 to 4000 m with Derating " data-placement="top" data-html="true" data-container="body" data-content="Over 1000 m, load reduced by 5% per 1000 m."> |
| Max. pollution degree per IEC/EN 61800-5-1 | 2 (non-conductive pollution) |
| Ambient conditions per IEC 60721-3-3 | Class 3C3 and 3S2 |
Ambient conditions
| Temperature – Operation | -10 to 45°C without derating ; 45 to 60°C with derating |
| Temperature – Storage | -25 to 60°C |
| Max. vibration resistance | Operation at switching frequency 2 or 4 kHz: Above +45°C, reduce rated output current by 2.5%/°C EN 60721-3-3:1995 + A2:1997 ; ; Operation at switching frequency 8 or 16 kHz: Above +40°C, reduce rated output current by 2.5%/°C EN 60721-3-3:1995 + A2:1997 |
Mechanical properties
| Dimensions – Width | 60 mm |
| Dimensions – Height | 278 mm |
| Dimensions – Height without shield plate | 250 mm |
| Dimensions – Depth | 130 mm |
| Weight | 1.35 kg |
Downloads & documentation
Official documents from B&R, downloaded directly from the manufacturer.
Data sheets & manuals
| ACOPOSinverter P77 User´s Manuel | ZIP · 46 MB · 1.00 (10/09/2025) - EN |
CAD & dimension drawings
| ACOPOSinverter P77 CAD 2D 3D | ZIP · 3 MB · 1.00 (07/04/2025) |
Certificates (2)
| Certificate ACOPOSinverter P77 Safety | ZIP · 688 KB · 1.00 (04/08/2025) |
| E225616 UL Certificate of Compliance ACOPOSinverter_P77 | PDF · 499 KB · 1.00 (04/08/2025) |
More B&R parts
Available on requestB&R 8I77T400110.0P-000 – ACOPOSinverter P77, 3x 340-528 V; 1.1 kW (heavy duty)
Available on requestB&R 8I77T400150.0P-000 – ACOPOSinverter P77, 3x 340-528 V; 1.5 kW (heavy duty)
Available on requestB&R 8I77T400220.0P-000 – ACOPOSinverter P77, 3x 340-528 V; 2.2 kW (heavy duty)
Available on requestB&R 8I77T400300.0P-000 – ACOPOSinverter P77, 3x 340-528 V; 3 kW (heavy duty)
Available on requestB&R 8I77T400550.0P-000 – ACOPOSinverter P77, 3x 340-528 V; 5.5 kW (heavy duty)
Available on requestB&R 8I77T400750.0P-000 – ACOPOSinverter P77, 3x 340-528 V; 7.5 kW (heavy duty)
Available on requestB&R 8I77T401100.0P-000 – ACOPOSinverter P77, 3x 340-528 V; 11 kW (heavy duty)
Available on requestB&R 8I77T401500.0P-000 – ACOPOSinverter P77, 3x 340-528 V; 15 kW (heavy duty)