B&R 8CM020.12-3
Request a Quote
Quick facts
| Availability | Confirmed on request |
| Category | 4 mm² motor cables |
| Lifecycle | Active |
| Warranty | 12-month (new) · 3-month (used/refurbished) |
| Weight | 5.5 kg |
| Datasheet | Manufacturer datasheet ↗ |
Shipping & availability
When can 8CM020.12-3 be shipped?
8CM020.12-3 is sourced on request — request a quote and we'll confirm the exact availability and shipping timeline for this specific unit.
Can I pick up 8CM020.12-3 in person?
Local pickup from our Groningen, Netherlands warehouse may be possible — contact us before ordering to check availability and arrange a collection time.
Is express delivery available?
Yes — mention it when you request a quote for 8CM020.12-3 and we'll include express shipping options in our reply.
My factory is down and I need this urgently — can you help?
For a critical breakdown, contact us directly at +31 (0)50-7110348 or sales@partnerplc.com — we can look into same-day courier or dedicated taxi/hotshot delivery for 8CM020.12-3, subject to availability and destination.
• Can be used in cable drag chains
• Assembled specifically for use with ACOPOS 1180/1320 servo drives and B&R servo motors with motor connector size 1
Motor cable, length 20 m, 4x 4 mm² + 2x 0.75 mm² + 2x 1 mm², 8-pin female Intercontec motor connector size 1, can be used in cable drag chains
Specifications
General information
| Certifications – CE | Yes |
| Certifications – UKCA | Yes |
| Certifications – CRA (Cyber Resilience Act) | Not applicable |
| Certifications – UL | cULus E225616; Power conversion equipment |
| Cable cross section | 4 x 4 mm² + 2 x 0.75 mm² + 2 x 1 mm² |
| Durability | Oil resistance per HD 22.10 appendix A and DIN EN 60811-404 " data-placement="top" data-html="true" data-container="body" data-content="Values refer to the raw cable being used."> |
| Certification | E170315 cRUus AWM STYLE 21223 AWM I/II A/B 80°C 1000 V FT1 " data-placement="top" data-html="true" data-container="body" data-content="Values refer to the raw cable being used."> |
Cable construction
| Power lines – Quantity | 4 |
| Power lines – Wire insulation | PP |
| Power lines – Wire colors | Black, brown, blue, yellow/green |
| Power lines – Variant | Tinned copper stranded wire |
| Power lines – Cross section | 4 mm² |
| Power lines – Shield | No |
| Power lines – Stranding | No |
| Signal line – Quantity | 4 |
| Signal line – Wire insulation | PP |
| Signal line – Wire colors | White, white/red, white/blue, white/green |
| Signal line – Variant | Tinned copper stranded wire |
| Signal line – Cross section | 2 x 0.75 mm² + 2 x 1 mm² |
| Signal line – Shield | Individually shielded in pairs, tinned copper braiding, optical coverage >85% and foil shield |
| Signal line – Stranding | White with white/red and white/blue with white/green |
| Outer jacket – Material | TPU |
| Outer jacket – Color | Orange, similar to RAL 2003 flat |
| Outer jacket – Labeling | B&R 4 G 4 + (2x0.75)C + (2x1)C C E170315 cRUus AWM STYLE 21223 AWM I/II A/B 80°C 1000 V FT1 " data-placement="top" data-html="true" data-container="body" data-content="Values refer to the raw cable being used."> |
| Cable stranding | With filler elements and foil shield |
| Cable shield | Tinned copper braiding, optical coverage >85% and foil shield |
Connector
| Type | 8-pin female speedtec motor connector, size 1.0 |
| Mating cycles | <500 |
| Contacts | 8 (4 power and 4 signal contacts) |
| Degree of protection per EN 60529 | IP66/67 when connected |
Electrical properties " data-placement="top" data-html="true" data-container="body" data-content="Values refer to the raw cable being used.">
| Test voltage – Wire - Wire | 4 kV |
| Test voltage – Wire - Shield | 4 kV |
| Conductor resistance – Power lines | ≤5.1 Ω/km |
| Conductor resistance – Signal line | 0.75 mm²: ≤26.7 Ω/km, 1 mm²: ≤20 Ω/km |
| Current-carrying capacity per DIN VDE 0298 part 4, table 11 – Wall mounting | 30 A " data-placement="top" data-html="true" data-container="body" data-content="Limited to 30 A by the motor connector."> |
| Current-carrying capacity per DIN VDE 0298 part 4, table 11 – Installed in conduit or cable duct | 30 A " data-placement="top" data-html="true" data-container="body" data-content="Limited to 30 A by the motor connector."> |
| Current-carrying capacity per DIN VDE 0298 part 4, table 11 – Installed in cable tray | 30 A " data-placement="top" data-html="true" data-container="body" data-content="Limited to 30 A by the motor connector."> |
| Operating voltage | Max. 1000 VAC (UL) |
| Insulation resistance | ≥500 MΩ*km |
Ambient conditions " data-placement="top" data-html="true" data-container="body" data-content="Values refer to the raw cable being used.">
| Temperature – Moving | -20°C to +80°C |
| Temperature – Static | -20°C to +90°C |
Mechanical properties " data-placement="top" data-html="true" data-container="body" data-content="Values refer to the raw cable being used.">
| Dimensions – Length | 20 m |
| Dimensions – Diameter | 15.4 mm ±0.4 mm |
| Bend radius – Single bend | >48 mm |
| Bend radius – Moving | >119 mm |
| Drag chain data – Acceleration | Max. 50 m/s² (depends on the length of the travel path) |
| Drag chain data – Flex cycles " data-placement="top" data-html="true" data-container="body" data-content="At an ambient temperature from -20°C to +60°C."> | ≥5,000,000 |
| Drag chain data – Velocity | Max. 300 m/min |
| Weight | 5.5 kg |
Downloads & documentation
Official documents from B&R, downloaded directly from the manufacturer.
Data sheets & manuals
| Datasheet 8CM020.12-3 | PDF · 166 KB · 1.5 (05/18/2020) - EN |
| ACOPOS User´s Manual | PDF · 54 MB · 2.10 (05/23/2022) - EN |
Certificates (3)
| E225616 UL Certificate of Compliance ACOPOS | PDF · 242 KB · 1.1 (09/11/2019) |
| EU Declaration Servos ACOPOS | PDF · 271 KB · 2024-02 (10/29/2025) |
| UK Declaration Servos ACOPOS | PDF · 109 KB · 2022-09 (09/08/2022) |