B&R 8BCH0012.1312A-0
Request a Quote
Quick facts
| Availability | Confirmed on request |
| Category | 4 mm² hybrid motor cable |
| Lifecycle | Active |
| Warranty | 12-month (new) · 3-month (used/refurbished) |
| Weight | 4.6 kg |
| Datasheet | Manufacturer datasheet ↗ |
Shipping & availability
When can 8BCH0012.1312A-0 be shipped?
8BCH0012.1312A-0 is sourced on request — request a quote and we'll confirm the exact availability and shipping timeline for this specific unit.
Can I pick up 8BCH0012.1312A-0 in person?
Local pickup from our Groningen, Netherlands warehouse may be possible — contact us before ordering to check availability and arrange a collection time.
Is express delivery available?
Yes — mention it when you request a quote for 8BCH0012.1312A-0 and we'll include express shipping options in our reply.
My factory is down and I need this urgently — can you help?
For a critical breakdown, contact us directly at +31 (0)50-7110348 or sales@partnerplc.com — we can look into same-day courier or dedicated taxi/hotshot delivery for 8BCH0012.1312A-0, subject to availability and destination.
• Can be used in cable drag chains
• Motor and encoder wires in one cable
• Assembled specifically for use with ACOPOSmulti drive systems and B&R servo motors with option "Single-cable solution (hybrid)"
• speedtec - Innovative connector system for secure connections
• Integrated shield plate
A shield plate is attached to ACOPOSmulti 8BCH hybrid motor cables. If this shield plate is correctly installed on the respective ACOPOSmulti 8BVI inverter module, no additional shielding measures are necessary.
Specifications
General information
| Certifications – CE | Yes |
| Certifications – UKCA | Yes |
| Certifications – CRA (Cyber Resilience Act) | Not applicable |
| Certifications – UL | cULus E225616; Power conversion equipment |
| Cable cross section | 4x 4 mm² + 2x 1 mm² + (2x 1x 0.30 mm² + 2x 2x 0.15 mm²) |
| Durability | Oil resistance per EN 60811-2-1 " data-placement="top" data-html="true" data-container="body" data-content="Values refer to the raw cable being used."> |
Cable construction
| Power lines – Quantity | 4 |
| Power lines – Wire insulation | PP |
| Power lines – Wire colors | Black, brown, blue, yellow/green |
| Power lines – Variant | Copper stranded wire |
| Power lines – Cross section | 4 mm² |
| Power lines – Shield | No |
| Power lines – Stranding | No |
| Supply lines – Quantity | 2 |
| Supply lines – Wire insulation | PP |
| Supply lines – Wire colors | White/Blue, white/green |
| Supply lines – Variant | Tinned copper stranded wire |
| Supply lines – Cross section | 1 mm² |
| Supply lines – Shield | No |
| Supply lines – Stranding | No |
| Signal line – Quantity | 6 |
| Signal line – Wire insulation | PP |
| Signal line – Wire colors | Brown/Green, white/green, gray/pink, yellow/violet |
| Signal line – Variant | 2x copper stranded wire, 4x tinned copper stranded wire |
| Signal line – Cross section | 2x 0.30 mm², 4x 0.15 mm² |
| Signal line – Shield | Tinned copper braiding, optical coverage >85% and foil shield |
| Signal line – Stranding | Brown/Green with white/green, pink with gray and yellow with violet |
| Outer jacket – Material | PUR |
| Outer jacket – Color | Orange, similar to RAL 2003 flat |
| Cable stranding | With filler elements and foil shield |
| Cable shield | Tinned copper braiding, optical coverage >85% and foil shield |
Connector
| Type | 13-pin female speedtec hybrid motor connector |
| Mating cycles | <500 |
| Contacts | 13 |
| Additional connectors | 9-pin male DSUB connector; Mating cycles: <200; Contacts: 9; Degree of protection per EN 60529: IP20 when connected |
| Degree of protection per EN 60529 | IP66/67 when connected |
Electrical properties " data-placement="top" data-html="true" data-container="body" data-content="Values refer to the raw cable being used.">
| Test voltage – Wire - Wire | 4 kV |
| Test voltage – Wire - Shield | 4 kV |
| Conductor resistance – Power lines | ≤5 Ω/km |
| Conductor resistance – Supply lines | ≤19.5 Ω/km |
| Conductor resistance – Signal line | 0.30 mm²: ≤68 Ω/km, 0.15 mm²: ≤140 Ω/km |
| Current-carrying capacity per DIN VDE 0298 part 4, table 11 – Wall mounting | 30 A " data-placement="top" data-html="true" data-container="body" data-content="Limited to 30 A by the hybrid motor connector."> |
| Current-carrying capacity per DIN VDE 0298 part 4, table 11 – Installed in conduit or cable duct | 30 A " data-placement="top" data-html="true" data-container="body" data-content="Limited to 30 A by the hybrid motor connector."> |
| Current-carrying capacity per DIN VDE 0298 part 4, table 11 – Installed in cable tray | 30 A " data-placement="top" data-html="true" data-container="body" data-content="Limited to 30 A by the hybrid motor connector."> |
| Insulation resistance | ≥200 MΩ*km |
Ambient conditions " data-placement="top" data-html="true" data-container="body" data-content="Values refer to the raw cable being used.">
| Temperature – Moving | -20°C to +90°C |
| Temperature – Static | -20°C to +90°C |
Mechanical properties " data-placement="top" data-html="true" data-container="body" data-content="Values refer to the raw cable being used.">
| Dimensions – Length | 12 m |
| Dimensions – Diameter | 15.7 mm ±0.4 mm |
| Bend radius – Single bend | >48 mm |
| Bend radius – Moving | ≥121 mm |
| Drag chain data – Acceleration | Max. 50 m/s² (depends on the length of the travel path) |
| Drag chain data – Flex cycles | ≥3,000,000 |
| Drag chain data – Velocity | Max. 300 m/min |
| Weight | 4.6 kg |
Downloads & documentation
Official documents from B&R, downloaded directly from the manufacturer.
Data sheets & manuals
| Datasheet 8BCH0012.1312A-0 | PDF · 269 KB · 1.4 (11/10/2023) - EN |
Certificates (4)
| E225616 UL Certificate of Compliance ACOPOSmulti (UL 508C) | PDF · 282 KB · 1.30 (07/20/2022) |
| EU Declaration Servos ACOPOSmulti | PDF · 963 KB · 2026-06 (06/30/2026) |
| UK Declaration ACOPOSmicro | PDF · 109 KB · 2022-09 (09/12/2022) |
| UK Declaration Servos ACOPOSmulti | PDF · 337 KB · 2026-06 (06/29/2026) |