What is the ABB 1SBH101001R2080?

NS... contactor relays are used for switching auxiliary circuits and control circuits. - Poles: 8-pole contactor relays - Control circuit: AC operated with laminated magnet circuit - Accessories: a wide range of accessories is available.

Specifications

General

Order code (ABB product ID)1SBH101001R2080
TypeNS80E-20
LifecycleActive (current ABB product)

Ordering

Minimum Order Quantity1 piece
Customs Tariff Number85364900

Dimensions

Product Net Width45 mm
Product Net Depth / Length100.2 mm
Product Net Height68 mm
Product Net Weight0.26 kg

Technical

Number of Main Contacts NO0
Number of Main Contacts NC0
Number of Auxiliary Contacts NO8
Number of Auxiliary Contacts NC0
Number of Poles8P
StandardsIEC 60947-5-1 and EN 60947-5-1, UL 508, CSA C22.2 N°14
Rated Operational VoltageAuxiliary Circuit 690 V, Main Circuit 690 V
Rated Frequency (f)Auxiliary Circuit 50 / 60 Hz
Conventional Free-air Thermal Current (I<sub>th</sub>)acc. to IEC 60947-5-1, Θ = 40 °C 10 A
Rated Operational Current AC-15 (I<sub>e</sub>)(500 V) NC 2, (500 V) 2 A, (690 V) 2 A, (24 / 127 V) 6 A, (220 / 240 V) 4 A, (400 / 440 V) 3 A
Rated Operational Current DC-13 (I<sub>e</sub>)(24 V) 6 A / 144 W, (48 V) 2.8 A / 134 W, (72 V) 1 A / 72 W, (110 V) 0.55 A / 60 W, (125 V) 0.55 A / 69 W, (220 V) 0.27 A / 60 W, (250 V) 0.27 A / 68 W
Rated Short-time Withstand Current Low Voltage (I<sub>cw</sub>)for 0.1 s 140 A, for 1 s 100 A
Rated Insulation Voltage (U<sub>i</sub>)acc. to IEC 60947-5-1 and VDE 0110 (Gr. C) 690 V, acc. to UL/CSA 600 V
Rated Impulse Withstand Voltage (U<sub>imp</sub>)Auxiliary Circuit 6 kV
Maximum Electrical Switching Frequency(AC-15) 1200 cycles per hour, (DC-13) 900 cycles per hour
Maximum Mechanical Switching Frequency3600 cycles per hour
Rated Control Circuit Voltage (U<sub>c</sub>)50 Hz 24 V, 60 Hz 24 V
Coil Consumption1.5 W
Power Lossat 6 A per Pole 0.1 W
Operate TimeBetween Coil De-energization and NC Contact Closing 7 ... 22 ms, Between Coil De-energization and NO Contact Opening 5 ... 19 ms, Between Coil Energization and NC Contact Opening 6 ... 18 ms, Between Coil Energization and NO Contact Closing 9 ... 24 ms
Mounting on DIN RailTH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715, TH35-7.5 (35 x 7.5 mm Mounting Rail) acc. to IEC 60715
Connecting Capacity Auxiliary CircuitFlexible with Ferrule 1/2x 0.75 ... 2.5 mm², Flexible with Insulated Ferrule 1x 0.75 ... 2.5 mm², Flexible with Insulated Ferrule 2x 0.75 ... 1.5 mm², Rigid 1/2x 0.75 ... 2.5 mm²
Connecting Capacity Control CircuitFlexible with Ferrule 1/2x 0.75 ... 2.5 mm², Flexible with Insulated Ferrule 1x 0.75 ... 2.5 mm², Flexible with Insulated Ferrule 2x 0.75 ... 1.5 mm², Rigid 1/2x 0.75 ... 2.5 mm²
Wire Stripping LengthAuxiliary Circuit 9 mm, Control Circuit 9 mm
Degree of Protectionacc. to IEC 60529, IEC 60947-1, EN 60529 Auxiliary Terminals IP20, acc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20
Tightening TorqueAuxiliary Circuit 1 N·m, Control Circuit 1 N·m
Terminal TypeScrew Terminals
Product NameBlock Contactor Relay

Technical UL/CSA

Connecting Capacity Auxiliary Circuit UL/CSARigid Solid 1/2x 18-14 AWG, Rigid Stranded 1/2x 18-14 AWG
Tightening Torque UL/CSAAuxiliary Circuit 9 in·lb, Control Circuit 9 in·lb

Environmental

Ambient Air TemperatureClose to Contactor for Storage -60 ... +80 °C, Near Contactor for Operation in Free Air -40 ... 70 °C
Climatic WithstandCategory B according to IEC 60947-1 Annex Q
Maximum Operating Altitude PermissibleWithout Derating 3000 m
Resistance to Shock acc. to IEC 60068-2-27Closed, Shock Direction: C1 19 g, Closed, Shock Direction: C2 16 g, Open, Shock Direction: C1 8 g, Open, Shock Direction: C2 13 g, Shock Direction: A 20 g, Shock Direction: B1 5 g, Shock Direction: B2 15 g
Resistance to Vibrations3g Closed Position & 2g Open Position 5 ... 300 Hz

Material Compliance

RoHS InformationFollowing EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
WEEE B2C / B2BBusiness To Business
WEEE Category5. Small Equipment (No External Dimension More Than 50 cm)

External Classifications and Standards

Object Classification CodeK
ETIM 7EC000196 - Contactor relay
ETIM 8EC000196 - Contactor relay
ETIM 9EC000196 - Contactor relay
eClassV11.0 : 27371001
UNSPSC39121529
IDEA Granular Category Code (IGCC)4761 >> Magnet contactor, AC-switching

1SBH101001R2080: frequently asked questions

When can 1SBH101001R2080 be shipped?

1SBH101001R2080 is sourced on request — request a quote and we'll confirm the exact availability and shipping timeline for this specific unit.

Can I pick up 1SBH101001R2080 in person?

Local pickup from our Groningen, Netherlands warehouse may be possible — contact us before ordering to check availability and arrange a collection time.

Is express delivery available?

Yes — mention it when you request a quote for 1SBH101001R2080 and we'll include express shipping options in our reply.

My factory is down and I need this urgently — can you help?

For a critical breakdown, contact us directly at +31 (0)50-7110348 or sales@partnerplc.com — we can look into same-day courier or dedicated taxi/hotshot delivery for 1SBH101001R2080, subject to availability and destination.

More ABB parts

ABB 1SBH101001R2080Price and lead time confirmed within 1 business day
Request a Quote