B&R X20AI1744 Used Rev. F0
Request a Quote
Quick facts
| Availability | In stock — 1 available |
| Category | Analog I/O Modules |
| Warranty | 3-month |
| Datasheet | Manufacturer datasheet ↗ |
Shipping & availability
When can X20AI1744 be shipped?
X20AI1744 is in stock and typically ships within 1 business day via UPS, DHL or FedEx, worldwide.
Can I pick up X20AI1744 in person?
Local pickup from our Groningen, Netherlands warehouse may be possible — contact us before ordering to check availability and arrange a collection time.
Is express delivery available?
Yes — alongside standard UPS, DHL and FedEx shipping, express (next-day) delivery is available at checkout for in-stock items like X20AI1744.
My factory is down and I need this urgently — can you help?
For a critical breakdown, contact us directly at +31 (0)50-7110348 or sales@partnerplc.com — we can look into same-day courier or dedicated taxi/hotshot delivery for X20AI1744, subject to availability and destination.
• 1 full-bridge strain gauge input
• Data output rate configurable from 0.1 Hz to 7.5 kHz
• Special operating modes (synchronous mode and multiple sampling)
• Configurable filter level
This module works with both 4-wire and 6-wire strain gauge load cells. The concept applied by the module requires compensation in the measurement system. This compensation eliminates the absolute uncertainty in the measurement circuit, such as component tolerances, effective bridge voltage or zero point offset. The measurement precision refers to the absolute (compensated) value, which will only change as a result of changes in the operating temperature.
Accessories
Required accessories (order separately)
| X20BM15 | Bus modules — The bus module is the base for all X20 24 VDC I/O modules; The internal I/O supply is interconnected; Manual node number assignment; Indepe… |
| X20BM11 | Bus modules — Bus module for 24 VDC I/O modules; The internal I/O power supply is connected through. The bus module is the base for all 24 VDC I/O module… |
| X20TB12 | Terminal blocks — Tool-free wiring with push-in technology; Simple wire release using lever; Ability to label each terminal; Plain text labeling also possibl… |
Specifications
Short description
| I/O module | 1 full-bridge strain gauge input |
General information
| Diagnostics – Module run/error | Yes, using LED status indicator and software |
| Diagnostics – Open circuit | Yes, using LED status indicator and software |
| Diagnostics – Input | Yes, using LED status indicator and software |
| Power consumption – Bus | 0.01 W |
| Power consumption – Internal I/O | 0.5 W |
| Certifications – CE | Yes |
| Certifications – UKCA | Yes |
| Certifications – CRA (Cyber Resilience Act) | In preparation |
| Certifications – ATEX | Zone 2, II 3G Ex nA nC IIA T5 Gc; IP20, Ta (see X20 user's manual); FTZÚ 09 ATEX 0083X |
| Certifications – UL | cULus E115267; Industrial control equipment |
| Certifications – HazLoc | cCSAus 244665; Process control equipment; for hazardous locations; Class I, Division 2, Groups ABCD, T5 |
| Certifications – KC | Yes |
| B&R ID code | 0x1CDE |
| Status indicators | Channel status, operating state, module status |
| Additional power dissipation caused by actuators (resistive) [W] | Max. +0.36 " data-placement="top" data-html="true" data-container="body" data-content="Depends on the full-bridge strain gauge being used."> |
Full-bridge strain gauge
| Input filter – Cutoff frequency | 5 kHz |
| Input filter – Order | 3 |
| Input filter – Slope | 60 dB |
| Output of digital value – Broken bridge supply line | Value approaching 0 |
| Output of digital value – Broken sensor line | Value approaching ±end value (status bit "Line monitoring" is set in register "Module status") |
| Output of digital value – Valid range of values | 0xFF800001 to 0x007FFFFF (-8,388,607 to 8,388,607) |
| Strain gauge supply – Voltage | 5.5 VDC / Max. 65 mA |
| Strain gauge supply – Short-circuit and overload-proof | Yes |
| Strain gauge supply – Voltage drop for short-circuit protection | Max. 0.2 VDC at 65 mA and 25°C |
| Quantization " data-placement="top" data-html="true" data-container="body" data-content="Quantization depends on the strain gauge factor."> – 2 mV/V | 336 nV |
| Quantization " data-placement="top" data-html="true" data-container="body" data-content="Quantization depends on the strain gauge factor."> – 4 mV/V | 671 nV |
| Quantization " data-placement="top" data-html="true" data-container="body" data-content="Quantization depends on the strain gauge factor."> – 8 mV/V | 1.343 µV |
| Quantization " data-placement="top" data-html="true" data-container="body" data-content="Quantization depends on the strain gauge factor."> – 16 mV/V | 2.686 µV |
| Quantization " data-placement="top" data-html="true" data-container="body" data-content="Quantization depends on the strain gauge factor."> – 32 mV/V | 5.371 μV |
| Quantization " data-placement="top" data-html="true" data-container="body" data-content="Quantization depends on the strain gauge factor."> – 64 mV/V | 10.74 μV |
| Quantization " data-placement="top" data-html="true" data-container="body" data-content="Quantization depends on the strain gauge factor."> – 128 mV/V | 21.48 μV |
| Quantization " data-placement="top" data-html="true" data-container="body" data-content="Quantization depends on the strain gauge factor."> – 256 mV/V | 42.97 μV |
| Quantization " data-placement="top" data-html="true" data-container="body" data-content="Quantization depends on the strain gauge factor."> – 2 mV/V | 1.31 nV |
| Quantization " data-placement="top" data-html="true" data-container="body" data-content="Quantization depends on the strain gauge factor."> – 4 mV/V | 2.62 nV |
| Quantization " data-placement="top" data-html="true" data-container="body" data-content="Quantization depends on the strain gauge factor."> – 8 mV/V | 5.25 nV |
| Quantization " data-placement="top" data-html="true" data-container="body" data-content="Quantization depends on the strain gauge factor."> – 16 mV/V | 10.49 nV |
| Quantization " data-placement="top" data-html="true" data-container="body" data-content="Quantization depends on the strain gauge factor."> – 32 mV/V | 20.98 nV |
| Quantization " data-placement="top" data-html="true" data-container="body" data-content="Quantization depends on the strain gauge factor."> – 64 mV/V | 41.96 nV |
| Quantization " data-placement="top" data-html="true" data-container="body" data-content="Quantization depends on the strain gauge factor."> – 128 mV/V | 83.92 nV |
| Quantization " data-placement="top" data-html="true" data-container="body" data-content="Quantization depends on the strain gauge factor."> – 256 mV/V | 167.85 nV |
| Strain gauge factor | 2 to 256 mV/V, configurable using software |
| Connection | 4- or 6-wire connections " data-placement="top" data-html="true" data-container="body" data-content="With 6-wire connections, line compensation does not function (see section "Connection examples")."> |
| Input type | Differential, used to evaluate a full-bridge strain gauge |
| Digital converter resolution | 24-bit |
| Conversion time | Depends on the configured data output rate |
| Data output rate | 0.1 - 7500 samples per second, configurable using software (f DATA ) |
| ADC filter characteristics | Sigma-delta, see section "Filter characteristics of the sigma-delta A/D converter" |
| Operating range / Measurement sensor | 85 to 5000 Ω |
| Influence of cable length " data-placement="top" data-html="true" data-container="body" data-content="Sensor cable with twisted and shielded conductors, cable length as short as possible, cable routing separate from load circuits, without intermediate terminal to the sensor."> | See section "Calculation example". |
| Input protection | RC protection |
| Common-mode range | 0 to 3 VDC ; Permissible input voltage range (with regard to the electric potential strain gauge GND) on inputs "Input +" and "Input -" |
| Insulation voltage between input and bus | 500 V eff |
| Conversion procedure | Sigma-delta |
| Max. gain drift | 12 ppm/°C " data-placement="top" data-html="true" data-container="body" data-content="Based on the current measured value."> |
| Max. offset drift | 2 ppm/°C " data-placement="top" data-html="true" data-container="body" data-content="Based on the entire measurement range."> |
| Nonlinearity | <10 ppm " data-placement="top" data-html="true" data-container="body" data-content="Based on the entire measurement range."> |
Electrical properties
| Electrical isolation | Bus isolated from analog input and strain gauge supply voltage; Channel not isolated from I/O power supply |
Operating conditions
| Mounting orientation – Horizontal | Yes |
| Mounting orientation – Vertical | Yes |
| Installation elevation above sea level – 0 to 2000 m | No limitation |
| Installation elevation above sea level – >2000 m | Reduction of ambient temperature by 0.5°C per 100 m |
| Degree of protection per EN 60529 | IP20 |
Ambient conditions
| Temperature – Horizontal mounting orientation | -25 to 60°C |
| Temperature – Vertical mounting orientation | -25 to 50°C |
| Temperature – Derating | See section "Hardware configuration" |
| Temperature – Storage | -40 to 85°C |
| Temperature – Transport | -40 to 85°C |
| Relative humidity – Operation | 5 to 95%, non-condensing |
| Relative humidity – Storage | 5 to 95%, non-condensing |
| Relative humidity – Transport | 5 to 95%, non-condensing |
Mechanical properties
| Note | Order 1x terminal block X20TB12 separately.; Order 1x bus module X20BM11 separately. |
| Pitch | 12.5 +0.2 mm |
Downloads & documentation
Official documents from B&R, downloaded directly from the manufacturer.
Data sheets & manuals
| Data sheet X20AI1744 | PDF · 2 MB · 4.40 (07/31/2025) - EN |
| X20 Package leaflet ATEX/CSA | PDF · 2 MB · 1.4 (09/17/2024) |
| X20 System User´s Manual | PDF · 50 MB · 4.40 (03/10/2026) - EN |
CAD & dimension drawings
| 3D File DXF/STEP X20 Electronic module | ZIP · 10 KB · 1.0 (10/17/2005) |
| 3D File STEP X20 I/O-Slice | ZIP · 872 KB · 1.1 (03/13/2019) |
| Dimensions PDF X20 Electronic module | PDF · 3 KB · 1.0 (10/17/2005) |
Certificates (7)
| E115267 UL Certificate of Compliance X20 | PDF · 3 MB · 2026_08_27 (08/27/2026) |
| EU Data Act - X20 IO - Connected Product Information Notice | PDF · 92 KB · 1.00 (09/30/2025) |
| EU Declaration ATEX X20 | PDF · 218 KB · 2023-07 (09/05/2023) |
| EU Declaration of conformity PLC X20 | PDF · 169 KB · 2021/10 (11/08/2021) |
| FTZU 09 ATEX 0083X | PDF · 771 KB · 3.00 (10/12/2021) |
| UK Declaration PLC X20 | PDF · 151 KB · 2024-01 (01/18/2024) |
| X20, X67 KC certificates | PDF · 7 MB · 2.00 (08/17/2026) |
More B&R parts
UsedB&R X20BC0083 Used Rev. K3 – POWERLINK; I/O configuration and firmware update via the…
UsedB&R X20DO4649 Used Rev. E0 – 4 digital outputs; Relay module for 240 VAC / 30 VDC
UsedB&R X20BT9400 Used Rev. C0 – X2X Link bus transmitter; For seamless expansion of the…
NewB&R 3DO486.6 New Rev. G0 – 2005 digital output module, 32 transistor outputs 24 VDC
UsedB&R X20SI9100 Used Rev. G0 – 20 safe digital inputs; 4 pulse outputs; Sink circuit