B&R X20pd2113 New without box Rev. F0
Request a Quote
Quick facts
| Availability | In stock — 1 available |
| Category | Power Supplies |
| Warranty | 12-month |
| Datasheet | Manufacturer datasheet ↗ |
Shipping & availability
When can X20pd2113 be shipped?
X20pd2113 is in stock and typically ships within 1 business day via UPS, DHL or FedEx, worldwide.
Can I pick up X20pd2113 in person?
Local pickup from our Groningen, Netherlands warehouse may be possible — contact us before ordering to check availability and arrange a collection time.
Is express delivery available?
Yes — alongside standard UPS, DHL and FedEx shipping, express (next-day) delivery is available at checkout for in-stock items like X20pd2113.
My factory is down and I need this urgently — can you help?
For a critical breakdown, contact us directly at +31 (0)50-7110348 or sales@partnerplc.com — we can look into same-day courier or dedicated taxi/hotshot delivery for X20pd2113, subject to availability and destination.
• Integrated exchangeable microfuse
• Monitoring of the fuse
• Potential for routing as needed
• Can be used as feed module for the I/O supply
The potential distributor module with feed can provide 6x 24 VDC and 6x ground connections from the internal I/O supply on the terminals. This module can also be used instead of a special feed module for the internal I/O supply. The internal 24 VDC supply is connected to the terminal connections through a replaceable microfuse for protection. The 24 VDC feed and the functionality of the fuse are monitored.
Accessories
Required accessories (order separately)
| X20BM15 | Bus modules — The bus module is the base for all X20 24 VDC I/O modules; The internal I/O supply is interconnected; Manual node number assignment; Indepe… |
| X20BM11 | Bus modules — Bus module for 24 VDC I/O modules; The internal I/O power supply is connected through. The bus module is the base for all 24 VDC I/O module… |
| X20BM05 | Bus modules — The bus module is the base for all X20 supply modules; For creating voltage groups; The internal I/O supply is isolated to the left; Manual… |
| X20BM01 | Bus modules — Basis for all power supply modules; For creating potential groups; The internal I/O power supply is interrupted to the left. The bus module… |
| X20TB12 | Terminal blocks — Tool-free wiring with push-in technology; Simple wire release using lever; Ability to label each terminal; Plain text labeling also possibl… |
Specifications
Short description
| Potential distributor module with supply | 6x 24 VDC on the terminals, 6x ground on the terminals |
General information
| Diagnostics – Module run/error | Yes, using LED status indicator and software |
| Diagnostics – Fuse monitoring | Yes, using LED status indicator and software |
| Power consumption " data-placement="top" data-html="true" data-container="body" data-content="The specified values are maximum values. For examples of the exact calculation, see section "Mechanical and electrical configuration" in the X20 system user's manual."> – Bus | 0.12 W |
| Power consumption " data-placement="top" data-html="true" data-container="body" data-content="The specified values are maximum values. For examples of the exact calculation, see section "Mechanical and electrical configuration" in the X20 system user's manual."> – Internal I/O | 1.15 W " data-placement="top" data-html="true" data-container="body" data-content="When using the module without an external power supply."> |
| Power consumption " data-placement="top" data-html="true" data-container="body" data-content="The specified values are maximum values. For examples of the exact calculation, see section "Mechanical and electrical configuration" in the X20 system user's manual."> – External I/O | 1.15 W " data-placement="top" data-html="true" data-container="body" data-content="When using the module with an external power supply."> |
| Certifications – CE | Yes |
| Certifications – UKCA | Yes |
| Certifications – CRA (Cyber Resilience Act) | In preparation |
| Certifications – ATEX | Zone 2, II 3G Ex nA nC IIA T5 Gc; IP20, Ta (see X20 user's manual); FTZÚ 09 ATEX 0083X |
| Certifications – UL | cULus E115267; Industrial control equipment |
| Certifications – HazLoc | cCSAus 244665; Process control equipment; for hazardous locations; Class I, Division 2, Groups ABCD, T5 |
| Certifications – DNV | Temperature: B (0 to 55°C); Humidity: B (up to 100%); Vibration: B (4 g); EMC: B (bridge and open deck) |
| Certifications – CCS | Yes |
| Certifications – LR | ENV1 |
| Certifications – KR | Yes |
| Certifications – ABS | Yes |
| Certifications – BV | EC33B ; Temperature: 5 - 55°C; Vibration: 4 g; EMC: Bridge and open deck |
| Certifications – KC | Yes |
| B&R ID code | 0x267F |
| Status indicators | Operating state, module status |
| Additional power dissipation caused by actuators (resistive) [W] | - |
Input power supply with feed
| Nominal input voltage | 24 VDC -15% / +20% external, ground external |
| Input current | Max. 6 A |
| Fuse | Integrated 6.3 A, slow-blow, can be replaced |
| Behavior on short circuit | No protection available ; Use an external fuse. |
| Reverse polarity protection | No |
Output I/O power supply
| Behavior on short circuit – On 24 VDC power supply | Integrated fuse |
| Behavior on short circuit – On GND power supply | No protection available |
| Nominal output voltage | 24 VDC, ground |
| Permissible contact load | 6 A |
Operating conditions
| Mounting orientation – Horizontal | Yes |
| Mounting orientation – Vertical | Yes |
| Installation elevation above sea level – 0 to 2000 m | No limitation |
| Installation elevation above sea level – >2000 m | Reduction of ambient temperature by 0.5°C per 100 m |
| Degree of protection per EN 60529 | IP20 |
Ambient conditions
| Temperature – Horizontal mounting orientation | -25 to 60°C |
| Temperature – Vertical mounting orientation | -25 to 50°C |
| Temperature – Derating | - |
| Temperature – Storage | -40 to 85°C |
| Temperature – Transport | -40 to 85°C |
| Relative humidity – Operation | 5 to 95%, non-condensing |
| Relative humidity – Storage | 5 to 95%, non-condensing |
| Relative humidity – Transport | 5 to 95%, non-condensing |
Mechanical properties
| Note | Order 1x terminal block X20TB12 separately. ; Order 1x bus module X20BM01 or X20BM11 separately. |
| Pitch | 12.5 +0.2 mm |
Downloads & documentation
Official documents from B&R, downloaded directly from the manufacturer.
Data sheets & manuals
| Datasheet X20PD2113 | PDF · 763 KB · 3.30 (07/30/2025) - EN |
| X20 Package leaflet ATEX/CSA | PDF · 2 MB · 1.4 (09/17/2024) |
| X20 System User´s Manual | PDF · 50 MB · 4.40 (03/10/2026) - EN |
CAD & dimension drawings
| 3D File DXF/STEP X20 Electronic module | ZIP · 10 KB · 1.0 (10/17/2005) |
| 3D File STEP X20 I/O-Slice | ZIP · 872 KB · 1.1 (03/13/2019) |
| Dimensions PDF X20 Electronic module | PDF · 3 KB · 1.0 (10/17/2005) |