Wall mounting Parts

Showing 25–34 of 34 parts
B&R 8BVI1650HWSS.004-4 – ACOPOSmulti3 SafeMOTION EnDat 2.2 Gen2 inverter module
B&R
8BVI1650HWSS.004-4

ACOPOSmulti3 SafeMOTION EnDat 2.2 Gen2 inverter module

B&R 8BVI0014HWSA.000-1 – ACOPOSmulti SafeMOTION SinCos inverter module, 1.9 A, AS
B&R
8BVI0014HWSA.000-1

ACOPOSmulti SafeMOTION SinCos inverter module, 1.9 A, AS

B&R 8BVI0028HWSA.000-1 – ACOPOSmulti SafeMOTION SinCos inverter module, 3.8 A, AS
B&R
8BVI0028HWSA.000-1

ACOPOSmulti SafeMOTION SinCos inverter module, 3.8 A, AS

B&R 8BVI0055HWSA.000-1 – ACOPOSmulti SafeMOTION SinCos inverter module, 7.6 A, AS
B&R
8BVI0055HWSA.000-1

ACOPOSmulti SafeMOTION SinCos inverter module, 7.6 A, AS

B&R 8BVI0110HWSA.000-1 – ACOPOSmulti SafeMOTION SinCos inverter module, 15.1 A, AS
B&R
8BVI0110HWSA.000-1

ACOPOSmulti SafeMOTION SinCos inverter module, 15.1 A, AS

B&R 8BVI0220HWSA.000-1 – ACOPOSmulti SafeMOTION SinCos inverter module, 22 A, AS
B&R
8BVI0220HWSA.000-1

ACOPOSmulti SafeMOTION SinCos inverter module, 22 A, AS

B&R 8BVI0330HWSA.000-1 – ACOPOSmulti SafeMOTION SinCos inverter module, 33 A, AS
B&R
8BVI0330HWSA.000-1

ACOPOSmulti SafeMOTION SinCos inverter module, 33 A, AS

B&R 8BVI0660HWSA.000-1 – ACOPOSmulti SafeMOTION SinCos inverter module, 66 A, AS
B&R
8BVI0660HWSA.000-1

ACOPOSmulti SafeMOTION SinCos inverter module, 66 A, AS

B&R 8BVI0880HWSA.004-1 – ACOPOSmulti SafeMOTION SinCos inverter module, 88 A, AS
B&R
8BVI0880HWSA.004-1

ACOPOSmulti SafeMOTION SinCos inverter module, 88 A, AS

B&R 8BVI1650HWSS.000-1 – ACOPOSmulti SafeMOTION EnDat 2.2 inverter module, 165 A, AS
B&R
8BVI1650HWSS.000-1

ACOPOSmulti SafeMOTION EnDat 2.2 inverter module, 165 A, AS

Compare Wall mounting

Key specifications of the parts listed on this page, taken from the manufacturer's data sheets.

MPNDC bus capacitanceReduction of continuous current depending on installation elevation – Starting at 500 m above sea levelPeak currentEnergy efficiency (IE classification) – Nominal losses in standby modeWeight
8BVI1650HWSS.004-43630 µF16.5 A eff per 1000 m330 A eff16 W23 kg
8BVI0014HWSA.000-1165 µF0.19 A eff per 1000 m4.7 A eff8.5 WApprox. 2.6 kg
8BVI0028HWSA.000-1165 µF0.38 A eff per 1000 m9.5 A eff8.5 WApprox. 2.6 kg
8BVI0055HWSA.000-1165 µF0.76 A eff per 1000 m18.9 A eff8.5 WApprox. 2.7 kg
8BVI0110HWSA.000-1330 µF1.51 A eff per 1000 m37.7 A eff8.5 WApprox. 2.9 kg
8BVI0220HWSA.000-1495 µF2.2 A eff per 1000 m55 A eff11.3 WApprox. 5.2 kg
8BVI0330HWSA.000-1990 µF3.3 A eff per 1000 m83 A eff11.3 WApprox. 5.4 kg
8BVI0660HWSA.000-11980 µF6.6 A eff per 1000 m132 A eff11.3 WApprox. 10.9 kg
8BVI0880HWSA.004-11980 µF8.8 A eff per 1000 m176 A eff11.3 WApprox. 10.9 kg
8BVI1650HWSS.000-13630 µF16.5 A eff per 1000 m330 A eff14.3 W24.8 kg

Common to all listed parts

Support – Dynamic node allocation (DNA)Yes
Certifications – CEYes
Certifications – UKCAYes
Certifications – Functional safetyYes (openSAFETY)
Certifications – ULcULus E225616; Power conversion equipment
Cooling and mounting typeWall mounting
Voltage – Nominal750 VDC
VariantACOPOSmulti backplane