Ultrasonic sensors with analog output or digital output Parts

Showing 1–24 of 24 parts
Balluff BUS0016 – BUS M30K0-PWCET-150-S92K – Ultrasonic sensors with analog output or digital output
Balluff
BUS0016

BUS M30K0-PWCET-150-S92K – Ultrasonic sensors with analog output or digital output

Balluff BUS0015 – BUS M30K0-PWCET-350-S92K – Ultrasonic sensors with analog output or digital output
Balluff
BUS0015

BUS M30K0-PWCET-350-S92K – Ultrasonic sensors with analog output or digital output

Balluff BUS000W – BUS M18K0-NSXEP-060-EP00,3-GS92 – Ultrasonic sensors with analog output or digital output
Balluff
BUS000W

BUS M18K0-NSXEP-060-EP00,3-GS92 – Ultrasonic sensors with analog output or digital output

Balluff BUS000U – BUS M18K0-NSXEP-150-EP00,3-GS92 – Ultrasonic sensors with analog output or digital output
Balluff
BUS000U

BUS M18K0-NSXEP-150-EP00,3-GS92 – Ultrasonic sensors with analog output or digital output

Balluff BUS000T – BUS M18K0-PSXEP-030-EP00,3-GS92 – Ultrasonic sensors with analog output or digital output
Balluff
BUS000T

BUS M18K0-PSXEP-030-EP00,3-GS92 – Ultrasonic sensors with analog output or digital output

Balluff BUS000R – BUS M18K0-PSXEP-060-EP00,3-GS92 – Ultrasonic sensors with analog output or digital output
Balluff
BUS000R

BUS M18K0-PSXEP-060-EP00,3-GS92 – Ultrasonic sensors with analog output or digital output

Balluff BUS000P – BUS M18K0-PSXEP-150-EP00,3-GS92 – Ultrasonic sensors with analog output or digital output
Balluff
BUS000P

BUS M18K0-PSXEP-150-EP00,3-GS92 – Ultrasonic sensors with analog output or digital output

Balluff BUS000N – BUS M18K0-XBFX-030-S04K – Ultrasonic sensors with analog output or digital output
Balluff
BUS000N

BUS M18K0-XBFX-030-S04K – Ultrasonic sensors with analog output or digital output

Balluff BUS000M – BUS M18K0-XBFX-060-S04K – Ultrasonic sensors with analog output or digital output
Balluff
BUS000M

BUS M18K0-XBFX-060-S04K – Ultrasonic sensors with analog output or digital output

Balluff BUS000L – BUS M18K0-XBFX-150-S04K – Ultrasonic sensors with analog output or digital output
Balluff
BUS000L

BUS M18K0-XBFX-150-S04K – Ultrasonic sensors with analog output or digital output

Balluff BUS000K – BUS M18K0-XAFX-030-S04K – Ultrasonic sensors with analog output or digital output
Balluff
BUS000K

BUS M18K0-XAFX-030-S04K – Ultrasonic sensors with analog output or digital output

Balluff BUS000J – BUS M18K0-XAFX-060-S04K – Ultrasonic sensors with analog output or digital output
Balluff
BUS000J

BUS M18K0-XAFX-060-S04K – Ultrasonic sensors with analog output or digital output

Balluff BUS000H – BUS M18K0-XAFX-150-S04K – Ultrasonic sensors with analog output or digital output
Balluff
BUS000H

BUS M18K0-XAFX-150-S04K – Ultrasonic sensors with analog output or digital output

Balluff BUS000F – BUS Q80K0-XBER-600-S92K – Ultrasonic sensors with analog output or digital output
Balluff
BUS000F

BUS Q80K0-XBER-600-S92K – Ultrasonic sensors with analog output or digital output

Balluff BUS000E – BUS Q80K0-XAER-600-S92K – Ultrasonic sensors with analog output or digital output
Balluff
BUS000E

BUS Q80K0-XAER-600-S92K – Ultrasonic sensors with analog output or digital output

Balluff BUS000C – BUS Q80K0-NWXER-600-S92K – Ultrasonic sensors with analog output or digital output
Balluff
BUS000C

BUS Q80K0-NWXER-600-S92K – Ultrasonic sensors with analog output or digital output

Balluff BUS000A – BUS Q80K0-PWXER-600-S92K – Ultrasonic sensors with analog output or digital output
Balluff
BUS000A

BUS Q80K0-PWXER-600-S92K – Ultrasonic sensors with analog output or digital output

Balluff BUS0007 – BUS R05K0-PPXCR-025-S75G – Ultrasonic sensors with analog output or digital output
Balluff
BUS0007

BUS R05K0-PPXCR-025-S75G – Ultrasonic sensors with analog output or digital output

Balluff BUS0006 – BUS M12E0-NPXCR-020-S04G – Ultrasonic sensors with analog output or digital output
Balluff
BUS0006

BUS M12E0-NPXCR-020-S04G – Ultrasonic sensors with analog output or digital output

Balluff BUS0005 – BUS M12E0-PPXCR-020-S04G – Ultrasonic sensors with analog output or digital output
Balluff
BUS0005

BUS M12E0-PPXCR-020-S04G – Ultrasonic sensors with analog output or digital output

Balluff BUS0004 – BUS M18K0-XBER-040-S92K – Ultrasonic sensors with analog output or digital output
Balluff
BUS0004

BUS M18K0-XBER-040-S92K – Ultrasonic sensors with analog output or digital output

Balluff BUS0003 – BUS M18K0-XAER-040-S92K – Ultrasonic sensors with analog output or digital output
Balluff
BUS0003

BUS M18K0-XAER-040-S92K – Ultrasonic sensors with analog output or digital output

Balluff BUS0002 – BUS M18K0-NWXER-040-S92K – Ultrasonic sensors with analog output or digital output
Balluff
BUS0002

BUS M18K0-NWXER-040-S92K – Ultrasonic sensors with analog output or digital output

Balluff BUS0001 – BUS M18K0-PWXER-040-S92K – Ultrasonic sensors with analog output or digital output
Balluff
BUS0001

BUS M18K0-PWXER-040-S92K – Ultrasonic sensors with analog output or digital output

Compare Ultrasonic sensors with analog output or digital output

Key specifications of the parts listed on this page, taken from the manufacturer's data sheets.

MPNType designationRangeOperating voltage UbBalluff alternativesApproval/Conformity
BUS0016BUS M30K0-PWCET-150-S92K150...1500 mm15...30 VDC——
BUS0015BUS M30K0-PWCET-350-S92K350...3500 mm15...30 VDCBUS0044—
BUS000WBUS M18K0-NSXEP-060-EP00,3-GS92100...600 mm18...30 VDC—cULus, DC, Code 2CD7 CE
BUS000UBUS M18K0-NSXEP-150-EP00,3-GS92200 to 1500 mm18...30 VDCBUS004PcULus CE WEEE EAC
BUS000TBUS M18K0-PSXEP-030-EP00,3-GS9260 to 300 mm18...30 VDCBUS007HcULus CE WEEE
BUS000RBUS M18K0-PSXEP-060-EP00,3-GS92100...600 mm18...30 VDCBUS007JcULus CE WEEE
BUS000PBUS M18K0-PSXEP-150-EP00,3-GS92200 to 1500 mm18...30 VDCBUS007JcULus CE WEEE
BUS000NBUS M18K0-XBFX-030-S04K60 to 300 mm18...30 VDCBUS004WcULus CE WEEE EAC
BUS000MBUS M18K0-XBFX-060-S04K100...600 mm18...30 VDCBUS004McULus CE WEEE
BUS000LBUS M18K0-XBFX-150-S04K200 to 1500 mm18...30 VDCBUS004McULus CE WEEE
BUS000KBUS M18K0-XAFX-030-S04K60 to 300 mm18...30 VDCBUS004TcULus CE WEEE EAC
BUS000JBUS M18K0-XAFX-060-S04K100...600 mm18...30 VDCBUS0052cULus CE WEEE EAC
BUS000HBUS M18K0-XAFX-150-S04K200 to 1500 mm18...30 VDCBUS0052cULus CE WEEE
BUS000FBUS Q80K0-XBER-600-S92K600...6000 mm15...30 VDCBUS006KCE WEEE EAC
BUS000EBUS Q80K0-XAER-600-S92K600...6000 mm15...30 VDCBUS006KCE WEEE
BUS000CBUS Q80K0-NWXER-600-S92K600...6000 mm12...30 VDCBUS006ECE WEEE EAC
BUS000ABUS Q80K0-PWXER-600-S92K600...6000 mm12...30 VDCBUS006HCE WEEE EAC
BUS0007BUS R05K0-PPXCR-025-S75G25...250 mm10...30 VDC——
BUS0006BUS M12E0-NPXCR-020-S04G25...200 mm10...30 VDCBUS0063CE WEEE
BUS0005BUS M12E0-PPXCR-020-S04G25...200 mm10...30 VDCBUS0065CE WEEE
BUS0004BUS M18K0-XBER-040-S92K30...400 mm15...30 VDCBUS004WCE WEEE
BUS0003BUS M18K0-XAER-040-S92K30...400 mm15...30 VDCBUS004TCE WEEE
BUS0002BUS M18K0-NWXER-040-S92K30...400 mm12...30 VDCBUS007HCE WEEE
BUS0001BUS M18K0-PWXER-040-S92K30...400 mm12...30 VDCBUS007HCE WEEE

Common to all listed parts

Product groupUltrasonic sensors with analog output or digital output
Repeat accuracy0.2 %FS
ECLASS 14.027-27-28-06
ETIM 9.0EC001846
UNSPSC 1141111916