Key specifications of the parts listed on this page, taken from the manufacturer's data sheets.
| MPN | Protected area height[mm] [mm] | Response time[ms] [ms] | PFH[1/h] [1/h] | Weight[g] [g] | Dimensions[mm] [mm] |
|---|
| OY002S | 310 | 5.5 | 1,3E-08 | 1620 | 363 x 28 x 30 |
| OY004S | 610 | 9 | 1,8E-08 | 2345 | 663 x 28 x 30 |
| OY265S | 760 | 5 | 1,2E-08 | 2980 | 813 x 28 x 30 |
| OY241S | 160 | 3 | 9,2E-09 | 1395 | 213 x 28 x 30 |
| OY035S | 760 | 11 | 4,5E-08 | 2715 | 813 x 28 x 30 |
| OY059S | 1360 | 12.5 | 5,4E-08 | 4620 | 1413 x 28 x 30 |
| OY047S | 1060 | 14 | 1,4E-08 | 3800 | 1113 x 28 x 30 |
| OY289S | 1360 | 6.5 | 1,4E-08 | 4705 | 1413 x 28 x 30 |
| OY010S | 1510 | 20 | 3,2E-08 | 4925 | 1563 x 28 x 30 |
| OY288S | 1210 | 6 | 1,3E-08 | 4135 | 1263 x 28 x 30 |
| OY046S | 910 | 12 | 1,3E-08 | 3375 | 963 x 28 x 30 |
| OY034S | 610 | 9.5 | 3,9E-08 | 2355 | 663 x 28 x 30 |
| OY264S | 610 | 4.5 | 1,2E-08 | 2460 | 663 x 28 x 30 |
| OY058S | 1210 | 11.5 | 5,0E-08 | 4255 | 1263 x 28 x 30 |
| OY243S | 460 | 5 | 1,2E-08 | 2250 | 513 x 28 x 30 |
| OY001S | 160 | 4 | 1,0E-08 | 1270 | 213 x 28 x 30 |
| OY049S | 1360 | 17 | 1,7E-08 | 1645 | 1413 x 28 x 30 |
| OY266S | 910 | 6 | 1,3E-08 | 3195 | 963 x 28 x 30 |
| OY242S | 310 | 4 | 1,0E-08 | 1910 | 363 x 28 x 30 |
| OY048S | 1210 | 15.5 | 1,5E-08 | 4215 | 1263 x 28 x 30 |
| OY055S | 760 | 8 | 3,6E-08 | 2735 | 813 x 28 x 30 |
| OY043S | 460 | 7.5 | 9,5E-09 | 2000 | 513 x 28 x 30 |
| OY285S | 760 | 4.5 | 1,1E-08 | 2945 | 813 x 28 x 30 |
| OY284S | 610 | 4 | 1,1E-08 | 2495 | 663 x 28 x 30 |
Common to all listed parts
| Type of light | infrared light |
| Electrical design | PNP |
| Protection | IP 65; IP 67 |
| Operating voltage tolerance[%] [%] | 20 |
| Operating voltage[V] [V] | 24 DC |
| Protection class | III |
| Reverse polarity protection | yes |
| Power-on delay time[s] [s] | < 2 |