IFM OGD551
Request a Quote
Quick facts
| Availability | Confirmed on request |
| Category | All photoelectric sensors |
| Warranty | 12-month (new) · 3-month (used/refurbished) |
Shipping & availability
When can OGD551 be shipped?
OGD551 is sourced on request — request a quote and we'll confirm the exact availability and shipping timeline for this specific unit.
Can I pick up OGD551 in person?
Local pickup from our Groningen, Netherlands warehouse may be possible — contact us before ordering to check availability and arrange a collection time.
Is express delivery available?
Yes — mention it when you request a quote for OGD551 and we'll include express shipping options in our reply.
My factory is down and I need this urgently — can you help?
For a critical breakdown, contact us directly at +31 (0)50-7110348 or sales@partnerplc.com — we can look into same-day courier or dedicated taxi/hotshot delivery for OGD551, subject to availability and destination.
Small compact design with standard M18 thread and PMD time-of-flight technology Measurement to the nearest millimetre and monitoring of distances in the running process Colour-independent range Simultaneous output of distance value and reflectivity for increased process reliability Convenient operation via buttons or parameter setting via IO-Link
Specifications
Product characteristics
| Type of light | red light |
| Laser protection class | 1 |
| Housing | rectangular with M18 thread |
Electrical data
| Operating voltage[V] [V] | 18...30 DC; ("supply class 2" to cULus) |
| Current consumption[mA] [mA] | 45; (24 V) |
| Protection class | III |
| Reverse polarity protection | yes |
| Type of light | red light |
| Wave length[nm] [nm] | 650 |
Inputs / outputs
| Number of inputs and outputs | Number of digital outputs: 2; Number of analogue outputs: 1 |
Inputs
| Inputs | Laser On/ Off |
Outputs
| Total number of outputs | 2 |
| Electrical design | PNP/NPN; (parameterisable) |
| Number of digital outputs | 2 |
| Output function | 2 x normally open / normally closed; (parameterisable) |
| Max. current load per output[mA] [mA] | 100 |
| Number of analogue outputs | 1 |
| Analogue current output[mA] [mA] | 4...20; (IEC 61131-2) |
| Max. load[Ω] [Ω] | 500 |
| Analogue voltage output[V] [V] | 0...10; (IEC 61131-2) |
| Min. load resistance[Ω] [Ω] | 2500 |
| Short-circuit protection | yes |
| Type of short-circuit protection | pulsed |
| Overload protection | yes |
| Switching frequency DC[Hz] [Hz] | 60 |
Detection zone
| Max. light spot diameter[mm] [mm] | 5 |
| Light spot dimensions refer to | at maximum range |
| Background suppression[m] [m] | < 20 |
Measuring/setting range
| Setting range object reflectivity[%] [%] | 6...900; (reflectivity; 6 % black paper; 100 % white paper) |
| Measuring range[m] [m] | 0.05...1 |
| Sampling rate[Hz] [Hz] | 180 |
Software / programming
| Parameter setting options | Distance / reflectivity; hysteresis / window; sequence modulation to avoid mutual interference between up to 5 similar devices; sensitivity; current/voltage output |
Interfaces
| Communication interface | IO-Link |
| Transmission type | COM2 (38,4 kBaud) |
| IO-Link revision | 1.1.3 |
| SDCI standard | IEC 61131-9 |
| Profiles | Common - I&D; Identification and Diagnosis; Function; Locator; Function; ProductURI |
| Common - I&D | Identification and Diagnosis |
| Function | ProductURI |
| SIO mode | yes |
| Required master port type | A |
| Min. process cycle time[ms] [ms] | 5 |
| IO-Link process data (cyclical) | process value; 2 x 16; device status; 4; binary switching information; 2 |
| process value | 2 x 16 |
| device status | 4 |
| binary switching information | 2 |
| IO-Link functions (acyclical) | application specific tag; operating hours counter; switching cycles counter |
| Supported DeviceIDs | default; 1582 |
| default | 1582 |
| Note | For further information please see the IODD PDF file under "Downloads" |
Operating conditions
| Ambient temperature[°C] [°C] | -25...55 |
| Note on ambient temperature | In ambient temperatures < -10 °C a warm-up time is necessary.; Laser is off. |
| Storage temperature[°C] [°C] | -30...80 |
| Protection | IP 65; IP 67 |
Tests / approvals
| EMC | EN 60947-5-2 |
| Laser protection class | 1 |
| Notes on laser protection | Caution:; laser light; laser class:; 1; EN / IEC60825-1:2007; EN / IEC60825-1:2014; Complies with 21 CFR 1040.10 except for conformance with IEC 60825-1 Ed. 3, as described in Laser Notice No. 56, dated May 8, 2019. |
| Caution: | laser light |
| laser class: | 1 |
| MTTF[years] [years] | 258 |
| UL approval | Ta; -25...60 °C; Enclosure type; Type 1; power supply; Class 2; File number UL; E174191 |
| Ta | -25...60 °C |
| Enclosure type | Type 1 |
| power supply | Class 2 |
| File number UL | E174191 |
Mechanical data
| Weight[g] [g] | 134.8 |
| Housing | rectangular with M18 thread |
| Dimensions[mm] [mm] | 61.7 x 22.5 x 45.2 |
| Thread designation | M18 x 1 |
| Materials | housing: stainless steel (316L/1.4404); PPSU; ABS; PMMA; PBT / PC; EPDM; front pane: PMMA |
| Lens alignment | side lens |
Displays / operating elements
| 3 | pushbutton |
| Display | switching status; 2 x LED, yellow; 1 x alphanumeric display, 4-digit |
| switching status | 2 x LED, yellow |
| Operating elements | 3; pushbutton |
Accessories
| Items supplied | lock nuts: 2 |
Remarks
| Pack quantity | 1 pcs. |
Electrical connection - plug
| Connector | 1 x M12; coding: A |