Pepperl Fuchs NCN4-12GM35-N0-0,5M-V1-Y – Inductive sensor. Extended temperature range
Request a Quote
Quick facts
| Availability | Confirmed on request |
| Category | Inductive Sensors |
| Lifecycle | Active |
| Warranty | 12-month (new) · 3-month (used/refurbished) |
Shipping & availability
When can NCN4-12GM35-N0-0,5M-V1-Y be shipped?
NCN4-12GM35-N0-0,5M-V1-Y is sourced on request — request a quote and we'll confirm the exact availability and shipping timeline for this specific unit.
Can I pick up NCN4-12GM35-N0-0,5M-V1-Y in person?
Local pickup from our Groningen, Netherlands warehouse may be possible — contact us before ordering to check availability and arrange a collection time.
Is express delivery available?
Yes — mention it when you request a quote for NCN4-12GM35-N0-0,5M-V1-Y and we'll include express shipping options in our reply.
My factory is down and I need this urgently — can you help?
For a critical breakdown, contact us directly at +31 (0)50-7110348 or sales@partnerplc.com — we can look into same-day courier or dedicated taxi/hotshot delivery for NCN4-12GM35-N0-0,5M-V1-Y, subject to availability and destination.
Inductive sensor. Extended temperature range, Switching function: Normally closed (NC), Output type: NAMUR, Installation: non-flush, Output type: 2-wire, Thread mold: M12, Construction type: Cylindrical, thread, Series: Cylindrical type, Safety Integrity Level (SIL): SIL 2, Type of voltage: DC, Connection type: fixed cable with plug, Housing material: Stainless steel 1.4305 / AISI 303, Degree of protection: IP66 / IP67, Threading: M12 x 1, Material: PUR. Switching function: Normally closed (NC). Output type: NAMUR. Rated operating distance: 4 mm. Installation: non-flush. Assured operating distance: 0 ... 3.24 mm. Actual operating distance: 3.6 ... 4.4 mm typ.. Reduction factor rAl: 0.37. Reduction factor rCu: 0.36. Reduction factor r304: 0.74. Output type: 2-wire. Nominal voltage: 8.2 V (Ri approx. 1 kΩ). Switching frequency: 0 ... 800 Hz. Hysteresis: 1 ... 10 % typ. 5 %. Reverse polarity protection: reverse polarity protected. Short-circuit protection: yes. Current consumption: . Measuring plate not detectedmin. 3 mAMeasuring plate detected≤ 1 mA: . Measuring plate not detected: min. 3 mA. Measuring plate detected: ≤ 1 mA. Switching state indicator: all direction LED, yellow. Safety Integrity Level (SIL): SIL 2. MTTFd: 2520 a. Mission Time (TM): 20 a. Diagnostic Coverage (DC): 0 %. Standard conformity: . NAMUREN 60947-5-6:2000 IEC 60947-5-6:1999Electromagnetic compatibilityNE 21:2007StandardsEN IEC 60947-5-2: . NAMUR: EN 60947-5-6:2000 IEC 60947-5-6:1999. Electromagnetic compatibility: NE 21:2007. Standards: EN IEC 60947-5-2. UL approval: cULus Listed Load Type: General Purpose Circuitry: Class 2 Power Source Enclosure Type Rating: Type 1 Supply/Switching Voltage: 8.2 V DC. Ambient temperature: -25 ... 100 °C (-13 ... 212 °F). Storage temperature: -40 ... 100 °C (-40 ... 212 °F). Connection type: fixed cable with plug. Housing material: Stainless steel 1.4305 / AISI 303. Sensing face: PBT. Degree of protection: IP66 / IP67. Connector: . ThreadingM12 x 1Tightening torque0.6 NmNumber of pins2: . Threading: M12 x 1. Tightening torque: 0.6 Nm. Number of pins: 2. Cable: . Cable diameter4.8 mm ± 0.2 mmBending radius> 10 x cable diameterMaterialPURColorblackNumber of cores2Core cross section0.34 mm2LengthL0.5 m: . Cable diameter: 4.8 mm ± 0.2 mm. Bending radius: > 10 x cable diameter. Material: PUR. Color: black. Number of cores: 2. Core cross section: 0.34 mm2. Length: 0.5 m. Mass: 50 g. Dimensions: . Length35 mmDiameter12 mm: . Length: 35 mm. Diameter: 12 mm. Scope of delivery: 2 self locking nuts in scope of delivery. Use in the hazardous area: see instruction manuals
Specifications
General specifications
| Switching function | Normally closed (NC) |
| Output type | NAMUR |
| Rated operating distance | 4 mm sn |
| Installation | non-flush |
| Assured operating distance | 0 ... 3.24 mm sa |
| Actual operating distance | 3.6 ... 4.4 mm typ. sr |
| Reduction factor rAl | 0.37 |
| Reduction factor rCu | 0.36 |
| Reduction factor r304 | 0.74 |
| Output type | 2-wire |
Nominal ratings
| Nominal voltage | 8.2 V (Ri approx. 1 kΩ) Uo |
| Switching frequency | 0 ... 800 Hz f |
| Hysteresis | 1 ... 10 % typ. 5 % H |
| Reverse polarity protection | reverse polarity protected |
| Short-circuit protection | yes |
| Current consumption | |
| Measuring plate not detectedmin. 3 mAMeasuring plate detected≤ 1 mA | Measuring plate not detected |
| Measuring plate not detected | min. 3 mA |
| Measuring plate detected | ≤ 1 mA |
| Switching state indicator | all direction LED, yellow |
Functional safety related parameters
| Safety Integrity Level (SIL) | SIL 2 |
| MTTFd | 2520 a |
| Mission Time (TM) | 20 a |
| Diagnostic Coverage (DC) | 0 % |
Compliance with standards and directives
| Standard conformity | |
| NAMUREN 60947-5-6:2000 IEC 60947-5-6:1999Electromagnetic compatibilityNE 21:2007StandardsEN IEC 60947-5-2 | NAMUR |
| NAMUR | EN 60947-5-6:2000 IEC 60947-5-6:1999 |
| Electromagnetic compatibility | NE 21:2007 |
| Standards | EN IEC 60947-5-2 |
Approvals and certificates
| UL approval | cULus Listed Load Type: General Purpose Circuitry: Class 2 Power Source Enclosure Type Rating: Type 1 Supply/Switching Voltage: 8.2 V DC |
Ambient conditions
| Ambient temperature | -25 ... 100 °C (-13 ... 212 °F) |
| Storage temperature | -40 ... 100 °C (-40 ... 212 °F) |
Mechanical specifications
| Connection type | fixed cable with plug |
| Housing material | Stainless steel 1.4305 / AISI 303 |
| Sensing face | PBT |
| Degree of protection | IP66 / IP67 |
| Connector | |
| ThreadingM12 x 1Tightening torque0.6 NmNumber of pins2 | Threading |
| Threading | M12 x 1 |
| Tightening torque | 0.6 Nm |
| Number of pins | 2 |
| Cable | |
| Cable diameter4.8 mm ± 0.2 mmBending radius> 10 x cable diameterMaterialPURColorblackNumber of cores2Core cross section0.34 mm2LengthL0.5 m | Cable diameter |
| Cable diameter | 4.8 mm ± 0.2 mm |
| Bending radius | > 10 x cable diameter |
| Material | PUR |
| Color | black |
| Number of cores | 2 |
| Core cross section | 0.34 mm2 |
| Length | 0.5 m L |
| Mass | 50 g |
| Dimensions | |
| Length35 mmDiameter12 mm | Length |
| Length | 35 mm |
| Diameter | 12 mm |
General information
| Scope of delivery | 2 self locking nuts in scope of delivery |
| Use in the hazardous area | see instruction manuals |
More Pepperl Fuchs parts
Available on requestPepperl Fuchs NCN3-F31K2M-N4-B13-S – Inductive sensor. Extended temperature range
Available on requestPepperl Fuchs NCN3-F31K2M-N4-B23-S – Inductive sensor. Extended temperature range
Available on requestPepperl Fuchs NCN4-12GK35-N0 – Inductive sensor. Extended temperature range
Available on requestPepperl Fuchs NCN4-12GM35-N0 – Inductive sensor. Extended temperature range
Available on requestPepperl Fuchs NCN4-12GM35-N0-10M – Inductive sensor. Extended temperature range
Available on requestPepperl Fuchs NCN4-12GM35-N0-5M – Inductive sensor. Extended temperature range
Available on requestPepperl Fuchs NCN4-12GM35-N0-V1 – Inductive sensor. Extended temperature range
Available on requestPepperl Fuchs NCN4-12GM35-N0-Y191065 – Inductive sensor. Extended temperature range