Pepperl Fuchs NCN3-F31K2M-N4-B13-S – Inductive sensor. Extended temperature range
Request a Quote
Quick facts
| Availability | Confirmed on request |
| Category | Inductive Sensors |
| Lifecycle | Active |
| Warranty | 12-month (new) · 3-month (used/refurbished) |
Shipping & availability
When can NCN3-F31K2M-N4-B13-S be shipped?
NCN3-F31K2M-N4-B13-S is sourced on request — request a quote and we'll confirm the exact availability and shipping timeline for this specific unit.
Can I pick up NCN3-F31K2M-N4-B13-S in person?
Local pickup from our Groningen, Netherlands warehouse may be possible — contact us before ordering to check availability and arrange a collection time.
Is express delivery available?
Yes — mention it when you request a quote for NCN3-F31K2M-N4-B13-S and we'll include express shipping options in our reply.
My factory is down and I need this urgently — can you help?
For a critical breakdown, contact us directly at +31 (0)50-7110348 or sales@partnerplc.com — we can look into same-day courier or dedicated taxi/hotshot delivery for NCN3-F31K2M-N4-B13-S, subject to availability and destination.
Inductive sensor. Extended temperature range, Valve position detection, Solenoid valve output, Suitable for 2:1 technology, Switching function: 2 x normally closed (NC), Output type: NAMUR, Installation: flush mountable, Output type: 2-wire, Construction type: Dual sensor, Series: Dual sensor, Suitable for 2:1 technology, Safety Integrity Level (SIL): SIL 2, Type of voltage: DC, Equipment protection level Ga: IECEx TUR 17.0055X, Equipment protection level Gb: IECEx TUR 17.0055X. Switching function: 2 x normally closed (NC). Output type: NAMUR. Rated operating distance: 3 mm. Installation: flush mountable. Assured operating distance: 0 ... 2.4 mm For assured operating distance sar see Manual Functional Safety.. Actual operating distance: 2.7 ... 3.3 mm typ.. Actuating element: Stainless steel 1.4305 / AISI 303 8.5 mm x 8.5 mm x 0.5 mm. Reduction factor rAl: 0.4. Reduction factor rCu: 0.4. Reduction factor r304: 0.7. Reduction factor rSt37: 1. Reduction factor rBrass: 0.5. Output type: 2-wire. Nominal voltage: 8.2 V (Ri approx. 1 kΩ). Switching frequency: 0 ... 3 kHz. Hysteresis: typ. 5 %. Reverse polarity protection: reverse polarity protected. Short-circuit protection: yes. Suitable for 2:1 technology: yes , Reverse polarity protection diode not required. Current consumption: . Measuring plate not detected≥ 3 mAMeasuring plate detected≤ 1 mA: . Measuring plate not detected: ≥ 3 mA. Measuring plate detected: ≤ 1 mA. Time delay before availability: ≤ 1 ms. Safety Integrity Level (SIL): SIL 2. MTTFd: 1730 a. Mission Time (TM): 20 a. Diagnostic Coverage (DC): 0 %. Voltage: max. 32 V DC. Current: max. 240 mA. Short-circuit protection: no. Reverse polarity protection: yes, with reversed output LED is out of function, therfore more power for solenoid valve. Standard conformity: . NAMUREN 60947-5-6:2000 IEC 60947-5-6:1999Electromagnetic compatibilityNE 21:2007StandardsEN IEC 60947-5-2: . NAMUR: EN 60947-5-6:2000 IEC 60947-5-6:1999. Electromagnetic compatibility: NE 21:2007. Standards: EN IEC 60947-5-2. IECEx approval: . Equipment protection level GaIECEx TUR 17.0055XEquipment protection level GbIECEx TUR 17.0055XEquipment protection level GcIECEx TUR 20.0062XEquipment protection level DaIECEx TUR 17.0055XEquipment protection level DcIECEx TUR 20.0068X: . Equipment protection level Ga: IECEx TUR 17.0055X. Equipment protection level Gb: IECEx TUR 17.0055X. Equipment protection level Gc: IECEx TUR 20.0062X. Equipment protection level Da: IECEx TUR 17.0055X. Equipment protection level Dc: IECEx TUR 20.0068X. ATEX approval: . Equipment protection level GaTÜV 17 ATEX 8125 XEquipment protection level GbTÜV 17 ATEX 8125 XEquipment protection level GcTÜV 20 ATEX 8592 XEquipment protection level DaTÜV 17 ATEX 8125 XEquipment protection level DcTÜV 20 ATEX 8598 X: . Equipment protection level Ga: TÜV 17 ATEX 8125 X. Equipment protection level Gb: TÜV 17 ATEX 8125 X. Equipment protection level Gc: TÜV 20 ATEX 8592 X. Equipment protection level Da: TÜV 17 ATEX 8125 X. Equipment protection level Dc: TÜV 20 ATEX 8598 X. UL approval: cULus Listed Load Type: General Purpose Circuitry: Class 2 Power Source Enclosure Type Rating: Type 1 Supply/Switching Voltage: 8.2 V DC. Ordinary LocationE87056Hazardous LocationE501628Control drawing116-0455: . Ordinary Location: E87056. Hazardous Location: E501628. Control drawing: 116-0455. CCC approval: . Hazardous Location2020322315002305: . Hazardous Location: 2020322315002305. KCC approval: . Hazardous Location23-AV4BO-0113X: . Hazardous Location: 23-AV4BO-0113X. Ambient temperature: -40 ... 100 °C (-40 ... 212 °F). Storage temperature: -40 ... 100 °C (-40 ... 212 °F). Connection type: screw terminals. Connection (system side): Screw terminals, tightening torque min. 0.5 Nm Stripped length 7 mm , M20 x 1.5 cable gland , usable thread length 13.5 mm , screw-in depth max. 13.5 mm. Core cross section (system side): rigid: 0.14 ... 2.5 mm2 flexible: 0.14 ... 1.5 mm2 flexible with core-end sleeve: 0.25 ... 1.5 mm2. Connection (valve side): like connection (system side). Core cross section (valve side): like core cross section (system side). Housing material: PC (glass-fiber-reinforced Makrolon). Housing base: powder coated aluminum. Degree of protection: IP66 / IP68 / IP69. Tightening torque, fastening screws: ≤ 5 Nm. Tightening torque, housing screws: 1.5 Nm. Tightening torque, earthing screw: 1.5 Nm. Tightening torque, cable gland: M20 x 1.5 ; max. 11 Nm. Tightening torque, stopping plug: 2 Nm. Dimensions: . Height53 mmWidth100 mmLength106 mm: . Height: 53 mm. Width: 100 mm. Length: 106 mm. Use in the hazardous area: see instruction manuals
Specifications
General specifications
| Switching function | 2 x normally closed (NC) |
| Output type | NAMUR |
| Rated operating distance | 3 mm sn |
| Installation | flush mountable |
| Assured operating distance | 0 ... 2.4 mm For assured operating distance sar see Manual Functional Safety. sa |
| Actual operating distance | 2.7 ... 3.3 mm typ. sr |
| Actuating element | Stainless steel 1.4305 / AISI 303 8.5 mm x 8.5 mm x 0.5 mm |
| Reduction factor rAl | 0.4 |
| Reduction factor rCu | 0.4 |
| Reduction factor r304 | 0.7 |
| Reduction factor rSt37 | 1 |
| Reduction factor rBrass | 0.5 |
| Output type | 2-wire |
Nominal ratings
| Nominal voltage | 8.2 V (Ri approx. 1 kΩ) Uo |
| Switching frequency | 0 ... 3 kHz f |
| Hysteresis | typ. 5 % H |
| Reverse polarity protection | reverse polarity protected |
| Short-circuit protection | yes |
| Suitable for 2:1 technology | yes , Reverse polarity protection diode not required |
| Current consumption | |
| Measuring plate not detected≥ 3 mAMeasuring plate detected≤ 1 mA | Measuring plate not detected |
| Measuring plate not detected | ≥ 3 mA |
| Measuring plate detected | ≤ 1 mA |
| Time delay before availability | ≤ 1 ms tv |
Functional safety related parameters
| Safety Integrity Level (SIL) | SIL 2 |
| MTTFd | 1730 a |
| Mission Time (TM) | 20 a |
| Diagnostic Coverage (DC) | 0 % |
Valve circuit
| Voltage | max. 32 V DC |
| Current | max. 240 mA |
| Short-circuit protection | no |
| Reverse polarity protection | yes, with reversed output LED is out of function, therfore more power for solenoid valve |
Compliance with standards and directives
| Standard conformity | |
| NAMUREN 60947-5-6:2000 IEC 60947-5-6:1999Electromagnetic compatibilityNE 21:2007StandardsEN IEC 60947-5-2 | NAMUR |
| NAMUR | EN 60947-5-6:2000 IEC 60947-5-6:1999 |
| Electromagnetic compatibility | NE 21:2007 |
| Standards | EN IEC 60947-5-2 |
Approvals and certificates
| IECEx approval | |
| Equipment protection level GaIECEx TUR 17.0055XEquipment protection level GbIECEx TUR 17.0055XEquipment protection level GcIECEx TUR 20.0062XEquipment protection level DaIECEx TUR 17.0055XEquipment protection level DcIECEx TUR 20.0068X | Equipment protection level Ga |
| Equipment protection level Ga | IECEx TUR 17.0055X |
| Equipment protection level Gb | IECEx TUR 17.0055X |
| Equipment protection level Gc | IECEx TUR 20.0062X |
| Equipment protection level Da | IECEx TUR 17.0055X |
| Equipment protection level Dc | IECEx TUR 20.0068X |
| ATEX approval | |
| Equipment protection level GaTÜV 17 ATEX 8125 XEquipment protection level GbTÜV 17 ATEX 8125 XEquipment protection level GcTÜV 20 ATEX 8592 XEquipment protection level DaTÜV 17 ATEX 8125 XEquipment protection level DcTÜV 20 ATEX 8598 X | Equipment protection level Ga |
| Equipment protection level Ga | TÜV 17 ATEX 8125 X |
| Equipment protection level Gb | TÜV 17 ATEX 8125 X |
| Equipment protection level Gc | TÜV 20 ATEX 8592 X |
| Equipment protection level Da | TÜV 17 ATEX 8125 X |
| Equipment protection level Dc | TÜV 20 ATEX 8598 X |
| UL approval | cULus Listed Load Type: General Purpose Circuitry: Class 2 Power Source Enclosure Type Rating: Type 1 Supply/Switching Voltage: 8.2 V DC |
| Ordinary LocationE87056Hazardous LocationE501628Control drawing116-0455 | Ordinary Location |
| Ordinary Location | E87056 |
| Hazardous Location | E501628 |
| Control drawing | 116-0455 |
| CCC approval | |
| Hazardous Location2020322315002305 | Hazardous Location |
| Hazardous Location | 2020322315002305 |
| KCC approval | |
| Hazardous Location23-AV4BO-0113X | Hazardous Location |
| Hazardous Location | 23-AV4BO-0113X |
Ambient conditions
| Ambient temperature | -40 ... 100 °C (-40 ... 212 °F) |
| Storage temperature | -40 ... 100 °C (-40 ... 212 °F) |
Mechanical specifications
| Connection type | screw terminals |
| Connection (system side) | Screw terminals, tightening torque min. 0.5 Nm Stripped length 7 mm , M20 x 1.5 cable gland , usable thread length 13.5 mm , screw-in depth max. 13.5 mm |
| Core cross section (system side) | rigid: 0.14 ... 2.5 mm2 flexible: 0.14 ... 1.5 mm2 flexible with core-end sleeve: 0.25 ... 1.5 mm2 |
| Connection (valve side) | like connection (system side) |
| Core cross section (valve side) | like core cross section (system side) |
| Housing material | PC (glass-fiber-reinforced Makrolon) |
| Housing base | powder coated aluminum |
| Degree of protection | IP66 / IP68 / IP69 |
| Tightening torque, fastening screws | ≤ 5 Nm |
| Tightening torque, housing screws | 1.5 Nm |
| Tightening torque, earthing screw | 1.5 Nm |
| Tightening torque, cable gland | M20 x 1.5 ; max. 11 Nm |
| Tightening torque, stopping plug | 2 Nm |
| Dimensions | |
| Height53 mmWidth100 mmLength106 mm | Height |
| Height | 53 mm |
| Width | 100 mm |
| Length | 106 mm |
General information
| Use in the hazardous area | see instruction manuals |
More Pepperl Fuchs parts
Available on requestPepperl Fuchs NCN3-F31K2-N4-B13-S – Inductive sensor. Extended temperature range
Available on requestPepperl Fuchs NCN3-F31K2-N4-B33-S – Inductive sensor. Extended temperature range
Available on requestPepperl Fuchs NCN3-F31K2-N5-B13-S – Inductive sensor. Extended temperature range
Available on requestPepperl Fuchs NCN3-F31K2-N5-B33-S – Inductive sensor. Extended temperature range
Available on requestPepperl Fuchs NCN3-F31K2M-N4-B23-S – Inductive sensor. Extended temperature range
Available on requestPepperl Fuchs NCN4-12GK35-N0 – Inductive sensor. Extended temperature range
Available on requestPepperl Fuchs NCN4-12GM35-N0 – Inductive sensor. Extended temperature range
Available on requestPepperl Fuchs NCN4-12GM35-N0-0,5M-V1-Y – Inductive sensor. Extended temperature range

