| Availability | Confirmed on request |
| Category | Inductive Sensors |
| Lifecycle | Active |
| Warranty | 12-month (new) · 3-month (used/refurbished) |
Shipping & availability
When can NCN4-12GM35-N0-Y191065 be shipped?
NCN4-12GM35-N0-Y191065 is sourced on request — request a quote and we'll confirm the exact availability and shipping timeline for this specific unit.
Can I pick up NCN4-12GM35-N0-Y191065 in person?
Local pickup from our Groningen, Netherlands warehouse may be possible — contact us before ordering to check availability and arrange a collection time.
Is express delivery available?
Yes — mention it when you request a quote for NCN4-12GM35-N0-Y191065 and we'll include express shipping options in our reply.
My factory is down and I need this urgently — can you help?
For a critical breakdown, contact us directly at +31 (0)50-7110348 or sales@partnerplc.com — we can look into same-day courier or dedicated taxi/hotshot delivery for NCN4-12GM35-N0-Y191065, subject to availability and destination.
Inductive sensor. Extended temperature range, Switching function: Normally closed (NC), Output type: NAMUR, Installation: non-flush, Output type: 2-wire, Thread mold: M12, Construction type: Cylindrical, thread, Series: Cylindrical type, Type of voltage: DC, Equipment protection level Ga: IECEx PTB 11.0037X, Equipment protection level Gb: IECEx PTB 11.0037X, Equipment protection level Da: IECEx PTB 11.0037X, Equipment protection level Dc (tc): IECEx TUR 21.0018X, Equipment protection level Mb: IECEx PTB 11.0037X. Switching function: Normally closed (NC). Output type: NAMUR. Rated operating distance: 4 mm. Installation: non-flush. Assured operating distance: 0 ... 3.24 mm. Actual operating distance: 3.6 ... 4.4 mm typ.. Reduction factor rAl: 0.37. Reduction factor rCu: 0.36. Reduction factor r304: 0.74. Output type: 2-wire. Nominal voltage: 8.2 V (Ri approx. 1 kΩ). Switching frequency: 0 ... 800 Hz. Hysteresis: 1 ... 10 % typ. 5 %. Reverse polarity protection: reverse polarity protected. Short-circuit protection: yes. Current consumption: . Measuring plate not detectedmin. 3 mAMeasuring plate detected≤ 1 mA: . Measuring plate not detected: min. 3 mA. Measuring plate detected: ≤ 1 mA. Switching state indicator: all direction LED, yellow. MTTFd: 2520 a. Mission Time (TM): 20 a. Diagnostic Coverage (DC): 0 %. Standard conformity: . NAMUREN 60947-5-6:2000 IEC 60947-5-6:1999Electromagnetic compatibilityNE 21:2007StandardsEN IEC 60947-5-2: . NAMUR: EN 60947-5-6:2000 IEC 60947-5-6:1999. Electromagnetic compatibility: NE 21:2007. Standards: EN IEC 60947-5-2. IECEx approval: . Equipment protection level GaIECEx PTB 11.0037XEquipment protection level GbIECEx PTB 11.0037XEquipment protection level DaIECEx PTB 11.0037XEquipment protection level Dc (tc)IECEx TUR 21.0018XEquipment protection level MbIECEx PTB 11.0037X: . Equipment protection level Ga: IECEx PTB 11.0037X. Equipment protection level Gb: IECEx PTB 11.0037X. Equipment protection level Da: IECEx PTB 11.0037X. Equipment protection level Dc (tc): IECEx TUR 21.0018X. Equipment protection level Mb: IECEx PTB 11.0037X. ATEX approval: . Equipment protection level GaPTB 00 ATEX 2048 XEquipment protection level GbPTB 00 ATEX 2048 XEquipment protection level DaPTB 00 ATEX 2048 XEquipment protection level Dc (tc)TÜV 20 ATEX 8524 X: . Equipment protection level Ga: PTB 00 ATEX 2048 X. Equipment protection level Gb: PTB 00 ATEX 2048 X. Equipment protection level Da: PTB 00 ATEX 2048 X. Equipment protection level Dc (tc): TÜV 20 ATEX 8524 X. UL approval: cULus Listed Circuitry: Class 2 Power Source Enclosure Type Rating: Type 1 Supply/Switching Voltage: 8.2 V DC. Ordinary LocationE87056Hazardous LocationE501628Control drawing116-0452: . Ordinary Location: E87056. Hazardous Location: E501628. Control drawing: 116-0452. CCC approval: . Hazardous Location2024322315005860: . Hazardous Location: 2024322315005860. CML approval: on request. Ambient temperature: -25 ... 100 °C (-13 ... 212 °F). Storage temperature: -40 ... 100 °C (-40 ... 212 °F). Connection type: cable. Housing material: Stainless steel 1.4305 / AISI 303. Sensing face: PBT. Degree of protection: IP67. Cable: . Wire end ferrulesyesCable diameter4.6 mm ± 0.2 mmBending radius> 12 x cable diameterMaterialPVCColorblueNumber of cores2Core cross section0.34 mm2LengthL145 mm: . Wire end ferrules: yes. Cable diameter: 4.6 mm ± 0.2 mm. Bending radius: > 12 x cable diameter. Material: PVC. Color: blue. Number of cores: 2. Core cross section: 0.34 mm2. Length: 145 mm. Mass: 25 g. Dimensions: . Length35 mmDiameter12 mm: . Length: 35 mm. Diameter: 12 mm. Use in the hazardous area: see instruction manuals
Specifications
General specifications
| Switching function | Normally closed (NC) |
| Output type | NAMUR |
| Rated operating distance | 4 mm sn |
| Installation | non-flush |
| Assured operating distance | 0 ... 3.24 mm sa |
| Actual operating distance | 3.6 ... 4.4 mm typ. sr |
| Reduction factor rAl | 0.37 |
| Reduction factor rCu | 0.36 |
| Reduction factor r304 | 0.74 |
| Output type | 2-wire |
Nominal ratings
| Nominal voltage | 8.2 V (Ri approx. 1 kΩ) Uo |
| Switching frequency | 0 ... 800 Hz f |
| Hysteresis | 1 ... 10 % typ. 5 % H |
| Reverse polarity protection | reverse polarity protected |
| Short-circuit protection | yes |
| Current consumption | |
| Measuring plate not detectedmin. 3 mAMeasuring plate detected≤ 1 mA | Measuring plate not detected |
| Measuring plate not detected | min. 3 mA |
| Measuring plate detected | ≤ 1 mA |
| Switching state indicator | all direction LED, yellow |
Functional safety related parameters
| MTTFd | 2520 a |
| Mission Time (TM) | 20 a |
| Diagnostic Coverage (DC) | 0 % |
Compliance with standards and directives
| Standard conformity | |
| NAMUREN 60947-5-6:2000 IEC 60947-5-6:1999Electromagnetic compatibilityNE 21:2007StandardsEN IEC 60947-5-2 | NAMUR |
| NAMUR | EN 60947-5-6:2000 IEC 60947-5-6:1999 |
| Electromagnetic compatibility | NE 21:2007 |
| Standards | EN IEC 60947-5-2 |
Approvals and certificates
| IECEx approval | |
| Equipment protection level GaIECEx PTB 11.0037XEquipment protection level GbIECEx PTB 11.0037XEquipment protection level DaIECEx PTB 11.0037XEquipment protection level Dc (tc)IECEx TUR 21.0018XEquipment protection level MbIECEx PTB 11.0037X | Equipment protection level Ga |
| Equipment protection level Ga | IECEx PTB 11.0037X |
| Equipment protection level Gb | IECEx PTB 11.0037X |
| Equipment protection level Da | IECEx PTB 11.0037X |
| Equipment protection level Dc (tc) | IECEx TUR 21.0018X |
| Equipment protection level Mb | IECEx PTB 11.0037X |
| ATEX approval | |
| Equipment protection level GaPTB 00 ATEX 2048 XEquipment protection level GbPTB 00 ATEX 2048 XEquipment protection level DaPTB 00 ATEX 2048 XEquipment protection level Dc (tc)TÜV 20 ATEX 8524 X | Equipment protection level Ga |
| Equipment protection level Ga | PTB 00 ATEX 2048 X |
| Equipment protection level Gb | PTB 00 ATEX 2048 X |
| Equipment protection level Da | PTB 00 ATEX 2048 X |
| Equipment protection level Dc (tc) | TÜV 20 ATEX 8524 X |
| UL approval | cULus Listed Circuitry: Class 2 Power Source Enclosure Type Rating: Type 1 Supply/Switching Voltage: 8.2 V DC |
| Ordinary LocationE87056Hazardous LocationE501628Control drawing116-0452 | Ordinary Location |
| Ordinary Location | E87056 |
| Hazardous Location | E501628 |
| Control drawing | 116-0452 |
| CCC approval | |
| Hazardous Location2024322315005860 | Hazardous Location |
| Hazardous Location | 2024322315005860 |
| CML approval | on request |
Ambient conditions
| Ambient temperature | -25 ... 100 °C (-13 ... 212 °F) |
| Storage temperature | -40 ... 100 °C (-40 ... 212 °F) |
Mechanical specifications
| Connection type | cable |
| Housing material | Stainless steel 1.4305 / AISI 303 |
| Sensing face | PBT |
| Degree of protection | IP67 |
| Cable | |
| Wire end ferrulesyesCable diameter4.6 mm ± 0.2 mmBending radius> 12 x cable diameterMaterialPVCColorblueNumber of cores2Core cross section0.34 mm2LengthL145 mm | Wire end ferrules |
| Wire end ferrules | yes |
| Cable diameter | 4.6 mm ± 0.2 mm |
| Bending radius | > 12 x cable diameter |
| Material | PVC |
| Color | blue |
| Number of cores | 2 |
| Core cross section | 0.34 mm2 |
| Length | 145 mm L |
| Mass | 25 g |
| Dimensions | |
| Length35 mmDiameter12 mm | Length |
| Length | 35 mm |
| Diameter | 12 mm |
General information
| Use in the hazardous area | see instruction manuals |
More Pepperl Fuchs parts
Available on requestPepperl Fuchs NCN4-12GM35-N0-0,5M-V1-Y – Inductive sensor. Extended temperature range
Available on requestPepperl Fuchs NCN4-12GM35-N0-10M – Inductive sensor. Extended temperature range
Available on requestPepperl Fuchs NCN4-12GM35-N0-5M – Inductive sensor. Extended temperature range
Available on requestPepperl Fuchs NCN4-12GM35-N0-V1 – Inductive sensor. Extended temperature range
Available on requestPepperl Fuchs NCN4-12GM40-E2-3G-3D – Inductive sensor. Switching function: Normally open (NO)
Available on requestPepperl Fuchs NCN4-12GM40-E2-V1-3G-3D – Inductive sensor. Switching function: Normally open (NO)
Available on requestPepperl Fuchs NCN4-12GM40-Z0 – Inductive sensor. Switching function: Normally open (NO)
Available on requestPepperl Fuchs NCN4-12GM40-Z0-10M – Inductive sensor. Switching function: Normally open (NO)