Pepperl Fuchs LB9547-S70-0-0-1-0-M – Redundancy Field Unit. Standard enclosure for LB-System
Request a Quote
Quick facts
| Availability | Confirmed on request |
| Category | LB (Zone 2, Class I/Div. 2) |
| Lifecycle | Active |
| Warranty | 12-month (new) · 3-month (used/refurbished) |
Shipping & availability
When can LB9547-S70-0-0-1-0-M be shipped?
LB9547-S70-0-0-1-0-M is sourced on request — request a quote and we'll confirm the exact availability and shipping timeline for this specific unit.
Can I pick up LB9547-S70-0-0-1-0-M in person?
Local pickup from our Groningen, Netherlands warehouse may be possible — contact us before ordering to check availability and arrange a collection time.
Is express delivery available?
Yes — mention it when you request a quote for LB9547-S70-0-0-1-0-M and we'll include express shipping options in our reply.
My factory is down and I need this urgently — can you help?
For a critical breakdown, contact us directly at +31 (0)50-7110348 or sales@partnerplc.com — we can look into same-day courier or dedicated taxi/hotshot delivery for LB9547-S70-0-0-1-0-M, subject to availability and destination.
Redundancy Field Unit. Standard enclosure for LB-System, Max. 46 slots for I/O modules, Installation in Zone 2 or safe area, For MODBUS TCP/IP, Number of modules: 46, Material: Stainless steel, Redundancy, Fieldbus type: MODBUS TCP, Redundancy. Installed components: backplane LB9022E , backplane LB9024A. Bus coupler: 2. Supply: 6. I/O modules (single width): max. 46. I/O modules (dual width): max. 23. Connection: screw terminals, max. 10 mm2. Rated voltage: 24 V DC. Maximum safe voltage Um: 60 V. Redundancy: yes. Fieldbus type: MODBUS TCP. Connection: RJ-45 connector (not included with delivery). Redundancy: yes. Electromagnetic compatibility: . Directive 2014/30/EUEN 61326-1: . Directive 2014/30/EU: EN 61326-1. Degree of protection: EN 60529. Impact resistance: EN 60079-0. Ambient temperature: -20 ... 40 °C (-4 ... 104 °F). Storage temperature: -25 ... 70 °C (-13 ... 158 °F). Relative humidity: < 75 % (annual mean)< 95 % (30 d/year), no moisture condensation. Shock resistance: shock type I, shock duration 11 ms, shock amplitude 15 g, number of shocks 18. Vibration resistance: frequency range 10 ... 150 Hz; transition frequency: 57.56 Hz, amplitude/acceleration ± 0.075 mm/1 g; 10 cyclesfrequency range 5 ... 100 Hz; transition frequency: 13.2 Hz amplitude/acceleration ± 1 mm/0.7 g; 90 minutes at each resonance. Impact resistance: 7J. Enclosure cover: hinged door with cam lock and double-bit insert. Degree of protection: IP66, NEMA 4X. Cable entry: power supply (Ex e): 2 x M25 and 2 x stopping plugs bus (Ex e): 6 x M20 field signals (Ex i): 184 x M16 and 8 x stopping plugs. Material: . HousingStainless steel 1.4404 / AISI 316LSurfaceelectropolishedCable glandPolyamide (PA)SealNeoprene, fire-resistant, one pieceMaterial thicknessenclosure body: 1.2 mmenclosure cover: 1.5 mmmounting plate, gland plate: 3 mm: . Housing: Stainless steel 1.4404 / AISI 316L. Surface: electropolished. Cable gland: Polyamide (PA). Seal: Neoprene, fire-resistant, one piece. Material thickness: enclosure body: 1.2 mmenclosure cover: 1.5 mmmounting plate, gland plate: 3 mm. Mass: approx. 35 kg , without modules. Dimensions: (W x H x D) 800 x 800 x 300 mm (31.5 x 31.5 x 11.8 inch). Height800 mmWidth800 mmDepth300 mm: . Height: 800 mm. Width: 800 mm. Depth: 300 mm. Mounting: thru-holes Ø11 mm. Grounding: grounding bolt M10 , brass. Certificate: PF 16 CERT 1267 X. Marking II 3(1/2)G Ex e nA [ia Ga/ib Gb/ic] IIC T4 Gc [exsign] II 3(1/2)D Ex tc [ia Da/ib Db/ic] IIIC T135 °C Dc: . Marking: II 3(1/2)G Ex e nA [ia Ga/ib Gb/ic] IIC T4 Gc [exsign] II 3(1/2)D Ex tc [ia Da/ib Db/ic] IIIC T135 °C Dc. Directive conformity: . Directive 2014/34/EUEN 60079-0:2012 , EN 60079-15:2010 , EN 60079-31:2014: . Directive 2014/34/EU: EN 60079-0:2012 , EN 60079-15:2010 , EN 60079-31:2014. Marine approval: . Lloyd Register15/20021DNV GL MarineTAA0000034American Bureau of ShippingT1450280/UN: . Lloyd Register: 15/20021. DNV GL Marine: TAA0000034. American Bureau of Shipping: T1450280/UN. Supplementary information: EC-Type Examination Certificate, Statement of Conformity, Declaration of Conformity, Attestation of Conformity and instructions have to be observed where applicable. For information see www.pepperl-fuchs.com.
Specifications
General specifications
| Installed components | backplane LB9022E , backplane LB9024A |
Slots
| Bus coupler | 2 |
| Supply | 6 |
| I/O modules (single width) | max. 46 |
| I/O modules (dual width) | max. 23 |
Supply
| Connection | screw terminals, max. 10 mm2 |
| Rated voltage | 24 V DC Ur |
| Maximum safe voltage Um | 60 V |
| Redundancy | yes |
Fieldbus connection
| Fieldbus type | MODBUS TCP |
| Connection | RJ-45 connector (not included with delivery) |
| Redundancy | yes |
Directive conformity
| Electromagnetic compatibility | |
| Directive 2014/30/EUEN 61326-1 | Directive 2014/30/EU |
| Directive 2014/30/EU | EN 61326-1 |
Conformity
| Degree of protection | EN 60529 |
| Impact resistance | EN 60079-0 |
Ambient conditions
| Ambient temperature | -20 ... 40 °C (-4 ... 104 °F) |
| Storage temperature | -25 ... 70 °C (-13 ... 158 °F) |
| Relative humidity | < 75 % (annual mean)< 95 % (30 d/year), no moisture condensation |
| Shock resistance | shock type I, shock duration 11 ms, shock amplitude 15 g, number of shocks 18 |
| Vibration resistance | frequency range 10 ... 150 Hz; transition frequency: 57.56 Hz, amplitude/acceleration ± 0.075 mm/1 g; 10 cyclesfrequency range 5 ... 100 Hz; transition frequency: 13.2 Hz amplitude/acceleration ± 1 mm/0.7 g; 90 minutes at each resonance |
| Impact resistance | 7J |
Mechanical specifications
| Enclosure cover | hinged door with cam lock and double-bit insert |
| Degree of protection | IP66, NEMA 4X |
| Cable entry | power supply (Ex e): 2 x M25 and 2 x stopping plugs bus (Ex e): 6 x M20 field signals (Ex i): 184 x M16 and 8 x stopping plugs |
| Material | |
| HousingStainless steel 1.4404 / AISI 316LSurfaceelectropolishedCable glandPolyamide (PA)SealNeoprene, fire-resistant, one pieceMaterial thicknessenclosure body: 1.2 mmenclosure cover: 1.5 mmmounting plate, gland plate: 3 mm | Housing |
| Housing | Stainless steel 1.4404 / AISI 316L |
| Surface | electropolished |
| Cable gland | Polyamide (PA) |
| Seal | Neoprene, fire-resistant, one piece |
| Material thickness | enclosure body: 1.2 mmenclosure cover: 1.5 mmmounting plate, gland plate: 3 mm |
| Mass | approx. 35 kg , without modules |
| Dimensions | (W x H x D) 800 x 800 x 300 mm (31.5 x 31.5 x 11.8 inch) |
| Height800 mmWidth800 mmDepth300 mm | Height |
| Height | 800 mm |
| Width | 800 mm |
| Depth | 300 mm |
| Mounting | thru-holes Ø11 mm |
| Grounding | grounding bolt M10 , brass |
Data for application in connection with hazardous areas
| Certificate | PF 16 CERT 1267 X |
| Marking II 3(1/2)G Ex e nA [ia Ga/ib Gb/ic] IIC T4 Gc [exsign] II 3(1/2)D Ex tc [ia Da/ib Db/ic] IIIC T135 °C Dc | Marking |
| Marking | II 3(1/2)G Ex e nA [ia Ga/ib Gb/ic] IIC T4 Gc [exsign] II 3(1/2)D Ex tc [ia Da/ib Db/ic] IIIC T135 °C Dc |
| Directive conformity | |
| Directive 2014/34/EUEN 60079-0:2012 , EN 60079-15:2010 , EN 60079-31:2014 | Directive 2014/34/EU |
| Directive 2014/34/EU | EN 60079-0:2012 , EN 60079-15:2010 , EN 60079-31:2014 |
International approvals
| Marine approval | |
| Lloyd Register15/20021DNV GL MarineTAA0000034American Bureau of ShippingT1450280/UN | Lloyd Register |
| Lloyd Register | 15/20021 |
| DNV GL Marine | TAA0000034 |
| American Bureau of Shipping | T1450280/UN |
General information
| Supplementary information | EC-Type Examination Certificate, Statement of Conformity, Declaration of Conformity, Attestation of Conformity and instructions have to be observed where applicable. For information see www.pepperl-fuchs.com. |
More Pepperl Fuchs parts
Available on requestPepperl Fuchs LB9516-T6*-B-0**-**-*-Y* – Field Unit, Stainless Steel. Preconfigured enclosures for…
Available on requestPepperl Fuchs LB9516-T6*-B-M**-**-*-Y* – Field Unit, Stainless Steel. Preconfigured enclosures for…
Available on requestPepperl Fuchs LB9523-T7*-*-***-**-*-Y* – Redundancy Field Unit, Stainless Steel. Preconfigured…
Available on requestPepperl Fuchs LB9532-T60-B-0A0-00-0 – Field Unit, Stainless Steel. Standard enclosure for…
Available on requestPepperl Fuchs LB9547-T7*-*-***-**-*-Y* – Redundancy Field Unit, Stainless Steel. Preconfigured…
Available on requestPepperl Fuchs LB9568-T8*-*-***-**-*-Y* – Field Unit, Stainless Steel. Preconfigured enclosures for…
Available on requestPepperl Fuchs LC-Ex S03 BC – Leather bag. Leather case for Smart-Ex 03. Color: yellow.…
Available on requestPepperl Fuchs LC-Ex S03 SC – Leather bag. Leather case for Smart-Ex 03. Color: yellow.…