PUSH WIRE® Inline Splicing Connector; for solid and stranded conductors; max. 4 mm²; 2-conductor; transparent housing; Transparent cover; Surrounding air temperature: max 85°C (T85); 4,00 mm²
请求报价
产品概览
| 库存情况 | 需按需确认 |
| 分类 | Installation Terminal Blocks and Connectors |
| 生命周期状态 | active |
| 保修 | 12个月(全新)· 3个月(二手/翻新) |
发货与库存
2773-2401/995-020 何时可以发货?
2773-2401/995-020 属于按需采购产品——请申请报价,我们会为这一具体单品确认准确的库存情况及发货时间。
可以亲自到店提取 2773-2401/995-020 吗?
可以在我们位于荷兰格罗宁根的仓库安排自提——请在下单前联系我们,确认库存情况并预约提货时间。
是否提供快递服务?
可以——在为 2773-2401/995-020 申请报价时告诉我们,我们会在回复中附上快递发货选项。
我们的工厂停产了,急需这个零部件——你们能帮忙吗?
如遇紧急故障,请直接致电 +31 (0)50-7110348 或发邮件至 sales@partnerplc.com 联系我们——我们可根据库存情况及目的地,为 2773-2401/995-020 安排当日快递或专车加急配送。
<h2>Push wire® inline splicing connector, 2773 Series, PUSH WIRE®</h2><br/><br/>Push wire® inline splicing connector (item number 2773-2401/995-020) simplifies electrical installations. This series of PUSH WIRE® connectors ensures safe and quick connections in both surface-mounted and flush-mounted junction boxes in any building, regardless of installation complexity. Ensure that the strip lengths are between 10 and 11 mm when connecting conductors to push wire® inline splicing connector. Our splicing connector is rated for 450 V and is designed to handle a rated current of up to 32 A. As such, it is suitable for high-load applications. Featuring conductor terminals along with PUSH WIRE®, this product outperforms the competition. Our PUSH WIRE® connection uses the stiffness of the conductor to overcome the clamping spring's contact force, allowing faster and easier conductor clamping. Dimensions: (6.15 x 6.8 x 29.5) mm (width x height x depth). Depending on the conductor type, push wire® inline splicing connector is suitable for conductor cross sections ranging from 0.75 mm² to 4 mm².<br/><br/><h3></h3><br/><br/>Tin is used for coating the contact surfaces.<br/>
技术规格
Notes
| General safety information | NOTICE: Observe installation and safety instructions!Only to be used by electricians!Do not work under voltage/load!Use only for proper use!Observe national regulations/standards/guidelines!Observe technical specifications for the products!Observe the number of permissible potentials!Do not use damaged/dirty components!Observe conductor types, cross-sections and strip lengths!Insert conductor until it hits the product‘s backstop!Use original accessories!To be sold only with installation instructions! |
Electrical data - Ratings per IEC/EN
| Ratings per | EN 60664 |
| Nominal voltage (II/2) | 450 V |
| Rated impulse withstand voltage (II/2) | 4 kV |
| Rated current | 32 A |
| Legend (ratings) | (II / 2) ≙ Overvoltage category II / Pollution degree 2 |
| Ratings per | EN 60664 / EN 60664 / EN 60664 |
| Overvoltage category | III / III / II |
| Pollution degree | 3 / 2 / 2 |
| Nominal voltage | 450 V |
| Rated impulse withstand voltage | 4 kV |
| Rated current | 32 A |
Electrical data - Ratings per UL
| Approvals per | UL 486C |
| Rated voltage UL (Use Group C) | 600 V |
| Rated current UL (Use Group C) | 20 A |
| Approvals per | UL 486C / UL 486C / UL 486C |
| Use group | B / C / D |
| Rated voltage | 600 V |
| Rated current | 20 A |
Electrical data - General information
| Wiring direction | Side-entry wiring |
Connection data
| Clamping units | 2 |
| Total number of potentials | 1 |
Connection data - Connection 1
| Connection technology | PUSH WIRE® |
| Actuation type | Push-in |
| Solid conductor | 0.75 … 4 mm² / 18 … 12 AWG |
| Stranded conductor | 1.5 … 4 mm² |
| Fine-stranded conductor; with insulated ferrule | 0.75 … 1.5 mm² / 18 … 16 AWG |
| Fine-stranded conductor; with uninsulated ferrule | 1 … 1.5 mm² / 16 AWG |
| Conductor diameter | 1.6 … 2 mm / 18 … 12 AWG |
| Strip length | 10 … 11 mm / 0.39 … 0.43 inches |
| Wiring direction | Side-entry wiring |
Physical data
| Width | 6.15 mm / 0.242 inches |
| Height | 6.8 mm / 0.268 inches |
| Depth | 29.5 mm / 1.161 inches |
Material data
| Note (material data) | Information on material specifications can be found here |
| Color | transparent |
| Cover color | transparent |
| Material group | IIIa |
| Insulation material (main housing) | Polycarbonate (PC) |
| Flammability class per UL94 | V2 |
| Clamping spring material | Chrome-nickel spring steel (CrNi) |
| Contact material | Electrolytic copper (ECu) |
| Contact plating | Tin |
| Fire load | 0.038 MJ |
| Weight of insulation material | 0.8 g |
| Weight | 1.5 g |
Environmental requirements
| Ambient temperature (operation) | +85 °C |
| Processing temperature | -35 … +60 °C |
| Continuous operating temperature | 105 °C |
Commercial data
| PU (SPU) | 360 (20) pcs |
| Packaging type | Blister foil |
| Country of origin | DE |
| GTIN | 4066966349115 |
| Customs tariff number | 85369010000 |
Product Classification
| UNSPSC | 39121409 |
| ETIM 9.0 | EC000446 |
| ETIM 10.0 | EC000446 |
| ECCN | NO US CLASSIFICATION |
Environmental Product Compliance
| RoHS Compliance Status | Compliant,No Exemption |