Pepperl Fuchs NJ40-FP-SN-B1-P1-Y024207 – Inductive sensor. Extended temperature range
Request a Quote
Quick facts
| Availability | Confirmed on request |
| Category | Inductive Sensors |
| Lifecycle | Active |
| Warranty | 12-month (new) · 3-month (used/refurbished) |
Shipping & availability
When can NJ40-FP-SN-B1-P1-Y024207 be shipped?
NJ40-FP-SN-B1-P1-Y024207 is sourced on request — request a quote and we'll confirm the exact availability and shipping timeline for this specific unit.
Can I pick up NJ40-FP-SN-B1-P1-Y024207 in person?
Local pickup from our Groningen, Netherlands warehouse may be possible — contact us before ordering to check availability and arrange a collection time.
Is express delivery available?
Yes — mention it when you request a quote for NJ40-FP-SN-B1-P1-Y024207 and we'll include express shipping options in our reply.
My factory is down and I need this urgently — can you help?
For a critical breakdown, contact us directly at +31 (0)50-7110348 or sales@partnerplc.com — we can look into same-day courier or dedicated taxi/hotshot delivery for NJ40-FP-SN-B1-P1-Y024207, subject to availability and destination.
Inductive sensor. Extended temperature range, Switching function: Normally closed (NC), Output type: NAMUR with safety function, Installation: flush, Output type: 2-wire, Construction type: Rectangular, Series: Rectangular type, Type of voltage: DC, Equipment protection level Gb: IECEx PTB 11.0092X, Equipment protection level Da: IECEx PTB 11.0092X, Equipment protection level Mb: IECEx PTB 11.0092X, Equipment protection level Gb: PTB 00 ATEX 2049 X, Equipment protection level Da: PTB 00 ATEX 2049 X. Switching function: Normally closed (NC). Output type: NAMUR with safety function. Rated operating distance: 40 mm. Installation: flush. Assured operating distance: 0 ... 32.4 mm. Reduction factor rAl: 0.4. Reduction factor rCu: 0.3. Reduction factor r304: 0.85. Output type: 2-wire. Nominal voltage: 8.2 V (Ri approx. 1 kΩ). Switching frequency: 0 ... 100 Hz. Current consumption: . Measuring plate not detectedmin. 3 mAMeasuring plate detected≤ 1 mA: . Measuring plate not detected: min. 3 mA. Measuring plate detected: ≤ 1 mA. Standard conformity: . NAMUREN 60947-5-6:2000 IEC 60947-5-6:1999StandardsEN IEC 60947-5-2: . NAMUR: EN 60947-5-6:2000 IEC 60947-5-6:1999. Standards: EN IEC 60947-5-2. IECEx approval: . Equipment protection level GbIECEx PTB 11.0092XEquipment protection level DaIECEx PTB 11.0092XEquipment protection level MbIECEx PTB 11.0092X: . Equipment protection level Gb: IECEx PTB 11.0092X. Equipment protection level Da: IECEx PTB 11.0092X. Equipment protection level Mb: IECEx PTB 11.0092X. ATEX approval: . Equipment protection level GbPTB 00 ATEX 2049 XEquipment protection level DaPTB 00 ATEX 2049 X: . Equipment protection level Gb: PTB 00 ATEX 2049 X. Equipment protection level Da: PTB 00 ATEX 2049 X. UL approval: cULus Listed Load Type: General Purpose Circuitry: Class 2 Power Source Enclosure Type Rating: Type 1 Supply/Switching Voltage: 8.2 V DC. Ambient temperature: -40 ... 100 °C (-40 ... 212 °F). Connection type: screw terminals. Core cross section: up to 2.5 mm2 , stripped insulation length: 7 mm. Connection (system side): screw terminals , M20 x 1.5 cable gland , usable thread length 10 mm , screw-in depth max. 10 mm. Housing material: PBT. Sensing face: PBT. Degree of protection: IP68. Dimensions: . Height40 mmWidth84 mmLength84 mm: . Height: 40 mm. Width: 84 mm. Length: 84 mm. Use in the hazardous area: see instruction manuals
Specifications
General specifications
| Switching function | Normally closed (NC) |
| Output type | NAMUR with safety function |
| Rated operating distance | 40 mm sn |
| Installation | flush |
| Assured operating distance | 0 ... 32.4 mm sa |
| Reduction factor rAl | 0.4 |
| Reduction factor rCu | 0.3 |
| Reduction factor r304 | 0.85 |
| Output type | 2-wire |
Nominal ratings
| Nominal voltage | 8.2 V (Ri approx. 1 kΩ) Uo |
| Switching frequency | 0 ... 100 Hz f |
| Current consumption | |
| Measuring plate not detectedmin. 3 mAMeasuring plate detected≤ 1 mA | Measuring plate not detected |
| Measuring plate not detected | min. 3 mA |
| Measuring plate detected | ≤ 1 mA |
Compliance with standards and directives
| Standard conformity | |
| NAMUREN 60947-5-6:2000 IEC 60947-5-6:1999StandardsEN IEC 60947-5-2 | NAMUR |
| NAMUR | EN 60947-5-6:2000 IEC 60947-5-6:1999 |
| Standards | EN IEC 60947-5-2 |
Approvals and certificates
| IECEx approval | |
| Equipment protection level GbIECEx PTB 11.0092XEquipment protection level DaIECEx PTB 11.0092XEquipment protection level MbIECEx PTB 11.0092X | Equipment protection level Gb |
| Equipment protection level Gb | IECEx PTB 11.0092X |
| Equipment protection level Da | IECEx PTB 11.0092X |
| Equipment protection level Mb | IECEx PTB 11.0092X |
| ATEX approval | |
| Equipment protection level GbPTB 00 ATEX 2049 XEquipment protection level DaPTB 00 ATEX 2049 X | Equipment protection level Gb |
| Equipment protection level Gb | PTB 00 ATEX 2049 X |
| Equipment protection level Da | PTB 00 ATEX 2049 X |
| UL approval | cULus Listed Load Type: General Purpose Circuitry: Class 2 Power Source Enclosure Type Rating: Type 1 Supply/Switching Voltage: 8.2 V DC |
Ambient conditions
| Ambient temperature | -40 ... 100 °C (-40 ... 212 °F) |
Mechanical specifications
| Connection type | screw terminals |
| Core cross section | up to 2.5 mm2 , stripped insulation length: 7 mm |
| Connection (system side) | screw terminals , M20 x 1.5 cable gland , usable thread length 10 mm , screw-in depth max. 10 mm |
| Housing material | PBT |
| Sensing face | PBT |
| Degree of protection | IP68 |
| Dimensions | |
| Height40 mmWidth84 mmLength84 mm | Height |
| Height | 40 mm |
| Width | 84 mm |
| Length | 84 mm |
General information
| Use in the hazardous area | see instruction manuals |
More Pepperl Fuchs parts
Available on requestPepperl Fuchs NJ4-12GM50-WS-V12 – Inductive sensor. Switching function: Normally open (NO)
Available on requestPepperl Fuchs NJ4-30GM-N-200 – Inductive sensor. Extended temperature range
Available on requestPepperl Fuchs NJ4-30GM-N-200-10M – Inductive sensor. Extended temperature range
Available on requestPepperl Fuchs NJ4-F-N – Inductive sensor. Extended temperature range
Available on requestPepperl Fuchs NJ40-FP-SN-P1 – Inductive sensor. Switching function: Normally closed (NC)
Available on requestPepperl Fuchs NJ40-FP-SN-P4 – Inductive sensor. Switching function: Normally closed (NC)
Available on requestPepperl Fuchs NJ40+U10+E2
Available on requestPepperl Fuchs NJ40+U1+E2