Available on request

Pepperl Fuchs ICA-AI-I/U-IO-V1 – IO-Link converter. IO-Link converter with analog input…

MPN: ICA-AI-I/U-IO-V1 · Brand: Pepperl Fuchs
Price on request
Request a Quote

A real person replies, typically within 1 business day — see our privacy policy.

12-month warranty (new) · 3-month (used/refurbished)
30-day returns, no restocking fee on unused parts
Ships via

Quick facts

AvailabilityConfirmed on request
CategoryIO-Link Infrastructure
Lifecycleactive
Warranty12-month (new) · 3-month (used/refurbished)

Shipping & availability

When can ICA-AI-I/U-IO-V1 be shipped?

ICA-AI-I/U-IO-V1 is sourced on request — request a quote and we'll confirm the exact availability and shipping timeline for this specific unit.

Can I pick up ICA-AI-I/U-IO-V1 in person?

Local pickup from our Groningen, Netherlands warehouse may be possible — contact us before ordering to check availability and arrange a collection time.

Is express delivery available?

Yes — mention it when you request a quote for ICA-AI-I/U-IO-V1 and we'll include express shipping options in our reply.

My factory is down and I need this urgently — can you help?

For a critical breakdown, contact us directly at +31 (0)50-7110348 or sales@partnerplc.com — we can look into same-day courier or dedicated taxi/hotshot delivery for ICA-AI-I/U-IO-V1, subject to availability and destination.

IO-Link converter. IO-Link converter with analog input (current/voltage). UL File Number: E223772. MTTFd: 246 a. LED 1: Device status, diagnostics. LED 2: IO-Link status. Rated operating voltage: 18 ... 30 V. Nominal voltage: 24 V DC. Nominal current: 230 mA. Current consumption: typ. 30 mA. Surge protection: Category II. Interface type: IO-Link. IO-Link revision: 1.1. Device ID: 0x0F0501 (984321). Transfer rate: COM2 (38.4 kBit/s). Min. cycle time: 2.3 ms. Process data width: 16 bits / 2 bytes. SIO mode support: no. Compatible master port type: A, B. Number/Type: 1 analog input for sensors with analog output. Sensor supply: 17 … 29.8 V DC ≤ 200 mA. Measuring range: Current input or voltage input, configurable: 0 mA…20 mA4 mA…20 mA0 V…10 V-10 V…10 V. Accuracy: 0.1 % FS at 25 °C. Resolution: ADC: 24 Bit Process data: 16 bit. Sampling rate: max. 200 Hz. Input filter: Average determination of process data, parameterizable. Temperature influence: 45 ppm/°K. Electromagnetic compatibility: . Directive 2014/30/EUEN 61000-6-2:2005, EN 61000-6-4:2007+A1:2011: . Directive 2014/30/EU: EN 61000-6-2:2005, EN 61000-6-4:2007+A1:2011. Degree of protection: EN 60529:2000. Fieldbus standard: IEC 61131-9 / IO-Link V1.1. Emitted interference: EN 61000-6-4. Noise immunity: EN 61000-4-2, EN 61000-4-3, EN 61000-4-4, EN 61000-4-6. Shock resistance: EN 60068, Part 2-6, Part 2-27. Ambient temperature: -30 ... 70 °C (-22 ... 158 °F). Storage temperature: -40 ... 85 °C (-40 ... 185 °F). Relative humidity: max. 85 %. Climatic conditions: Climatic class 3K3. Altitude: 0 ... 2000 m. Shock and impact resistance: 50 g, 11 ms, all axes. Pollution degree: 3. Degree of protection: IP67. Connection: IO-Link M12, A-coded Input M12, A-coded. Material: . ContactsZinc, CuNi platedHousingPlastic PC + PBT: . Contacts: Zinc, CuNi plated. Housing: Plastic PC + PBT. Mass: 44 g. Dimensions: . Height32.3 mmWidth16 mmLength79.7 mm: . Height: 32.3 mm. Width: 16 mm. Length: 79.7 mm. Construction type: Field housing

Specifications

General specifications

UL File NumberE223772

Functional safety related parameters

MTTFd246 a

Indicators/operating means

LED 1Device status, diagnostics
LED 2IO-Link status

Electrical specifications

Rated operating voltage18 ... 30 V Ue
Nominal voltage24 V DC
Nominal current230 mA
Current consumptiontyp. 30 mA
Surge protectionCategory II

Interface

Interface typeIO-Link
IO-Link revision1.1
Device ID0x0F0501 (984321)
Transfer rateCOM2 (38.4 kBit/s)
Min. cycle time2.3 ms
Process data width16 bits / 2 bytes
SIO mode supportno
Compatible master port typeA, B

Input

Number/Type1 analog input for sensors with analog output
Sensor supply17 … 29.8 V DC ≤ 200 mA
Measuring rangeCurrent input or voltage input, configurable: 0 mA…20 mA4 mA…20 mA0 V…10 V-10 V…10 V
Accuracy0.1 % FS at 25 °C
ResolutionADC: 24 Bit Process data: 16 bit
Sampling ratemax. 200 Hz
Input filterAverage determination of process data, parameterizable
Temperature influence45 ppm/°K

Directive conformity

Electromagnetic compatibility
Directive 2014/30/EUEN 61000-6-2:2005, EN 61000-6-4:2007+A1:2011 Directive 2014/30/EU
Directive 2014/30/EUEN 61000-6-2:2005, EN 61000-6-4:2007+A1:2011

Standard conformity

Degree of protectionEN 60529:2000
Fieldbus standardIEC 61131-9 / IO-Link V1.1
Emitted interferenceEN 61000-6-4
Noise immunityEN 61000-4-2, EN 61000-4-3, EN 61000-4-4, EN 61000-4-6
Shock resistanceEN 60068, Part 2-6, Part 2-27

Ambient conditions

Ambient temperature-30 ... 70 °C (-22 ... 158 °F)
Storage temperature-40 ... 85 °C (-40 ... 185 °F)
Relative humiditymax. 85 %
Climatic conditionsClimatic class 3K3
Altitude0 ... 2000 m
Shock and impact resistance50 g, 11 ms, all axes
Pollution degree3

Mechanical specifications

Degree of protectionIP67
ConnectionIO-Link M12, A-coded Input M12, A-coded
Material
ContactsZinc, CuNi platedHousingPlastic PC + PBT Contacts
ContactsZinc, CuNi plated
HousingPlastic PC + PBT
Mass44 g
Dimensions
Height32.3 mmWidth16 mmLength79.7 mm Height
Height32.3 mm
Width16 mm
Length79.7 mm
Construction typeField housing
12-month warrantyon all new stock
3-month warrantyon used & refurbished parts
30-day returnsno restocking fee on unused parts
Global shippingFast, tracked delivery worldwide

More Pepperl Fuchs parts

Pepperl Fuchs ICA-16IO-G20-IO-P16 – I/O hub IO-Link. G20 IO-Link I/O Hub for 16 freely…Available on requestPepperl Fuchs ICA-16IO-G20-IO-P16 – I/O hub IO-Link. G20 IO-Link I/O Hub for 16 freely…
MPN: ICA-16IO-G20-IO-P16 · Pepperl Fuchs
Price on request
Request a quote
Pepperl Fuchs ICA-8DIO-CB10-IO – IO-Link printed circuit board module. I/O hub with IO-Link…Available on requestPepperl Fuchs ICA-8DIO-CB10-IO – IO-Link printed circuit board module. I/O hub with IO-Link…
MPN: ICA-8DIO-CB10-IO · Pepperl Fuchs
Price on request
Request a quote
Pepperl Fuchs ICA-8DIO4M1-G20-IO – IO-Link Motor Roller Module. G20 MDR module with IO-Link…Available on requestPepperl Fuchs ICA-8DIO4M1-G20-IO – IO-Link Motor Roller Module. G20 MDR module with IO-Link…
MPN: ICA-8DIO4M1-G20-IO · Pepperl Fuchs
Price on request
Request a quote
Pepperl Fuchs ICA-8IO-4M4-G20-IO-P14 – IO-Link Motor Roller Module. G20 MDR module with IO-Link…Available on requestPepperl Fuchs ICA-8IO-4M4-G20-IO-P14 – IO-Link Motor Roller Module. G20 MDR module with IO-Link…
MPN: ICA-8IO-4M4-G20-IO-P14 · Pepperl Fuchs
Price on request
Request a quote
Pepperl Fuchs ICA-AO-I/U-IO-V1 – IO-Link converter. IO-Link converter with analog output…Available on requestPepperl Fuchs ICA-AO-I/U-IO-V1 – IO-Link converter. IO-Link converter with analog output…
MPN: ICA-AO-I/U-IO-V1 · Pepperl Fuchs
Price on request
Request a quote
Pepperl Fuchs ICA-F85E2-MC-IO-V1 – Push button box. Programmable push button box with IO-Link…Available on requestPepperl Fuchs ICA-F85E2-MC-IO-V1 – Push button box. Programmable push button box with IO-Link…
MPN: ICA-F85E2-MC-IO-V1 · Pepperl Fuchs
Price on request
Request a quote
Pepperl Fuchs ICA-IIOT-KIT2G-IOAvailable on requestPepperl Fuchs ICA-IIOT-KIT2G-IO
MPN: ICA-IIOT-KIT2G-IO · Pepperl Fuchs
Price on request
Request a quote