Available on request

Pepperl Fuchs ICA-16IO-G20-IO-P16 – I/O hub IO-Link. G20 IO-Link I/O Hub for 16 freely…

MPN: ICA-16IO-G20-IO-P16 · Brand: Pepperl Fuchs
Price on request
Request a Quote

A real person replies, typically within 1 business day — see our privacy policy.

12-month warranty (new) · 3-month (used/refurbished)
30-day returns, no restocking fee on unused parts
Ships via

Quick facts

AvailabilityConfirmed on request
CategoryIO-Link Infrastructure
LifecycleActive
Warranty12-month (new) · 3-month (used/refurbished)

Shipping & availability

When can ICA-16IO-G20-IO-P16 be shipped?

ICA-16IO-G20-IO-P16 is sourced on request — request a quote and we'll confirm the exact availability and shipping timeline for this specific unit.

Can I pick up ICA-16IO-G20-IO-P16 in person?

Local pickup from our Groningen, Netherlands warehouse may be possible — contact us before ordering to check availability and arrange a collection time.

Is express delivery available?

Yes — mention it when you request a quote for ICA-16IO-G20-IO-P16 and we'll include express shipping options in our reply.

My factory is down and I need this urgently — can you help?

For a critical breakdown, contact us directly at +31 (0)50-7110348 or sales@partnerplc.com — we can look into same-day courier or dedicated taxi/hotshot delivery for ICA-16IO-G20-IO-P16, subject to availability and destination.

I/O hub IO-Link. G20 IO-Link I/O Hub for 16 freely configurable digital inputs/outputs. UL File Number: E223772. MTBF: 149 a. LED green: : IO1..8 / IO9..16 bank indication. LED yellow/red: IO1 ... IO16: inputs/outputs status, IO-Link status. Operating voltage: 18 ... 30 V DC, PELV Current limitation of the supply max. 4 A. No-load supply current: ≤ 25 mA. Operating current: max. 4 A. Interface type: IO-Link. IO-Link revision: 1.1. Device profile: Identification and Diagnosis - I&D Firmware update. Process data: Inputs 3 Byte - Input signals 16 Bit - diagnosis signals 5 Bit Outputs 2 Byte - Output signals 16 Bit. Vendor ID: 1 (0x0001). Device ID: 985345 (0x0F0901). Data transfer rate: COM3 (230.4 kbits/s). Min. cycle time: 1 ms. SIO mode support: no. Compatible master port type: Class A. Number/Type: 16 Inputs for 3-wire sensors (PNP), DC (IO1 ... IO16). Supply: from IO-Link. Current loading capacity: 200 mA , overload and short-circuit protected. Input current: ≤ 5 mA (limited internally). Switching point: Type 3 according to IEC 61131-2. Number/Type: 16 electronic outputs, PNP (IO1 … IO16), overload-proof and short-circuit-proof. Supply: from IO-Link. Voltage: ≥ (UB - 1.5 V). Current: 200 mA per output. Electromagnetic compatibility: . Directive 2014/30/EUEN 61326-1:2013 EN 55011:2016: . Directive 2014/30/EU: EN 61326-1:2013 EN 55011:2016. Degree of protection: EN 60529:2000. Input: EN 61131-2:2007. Communication interface: IEC 61131-9:2013 / IO-Link V1.1.3. Emitted interference: EN 61000-6-4:2007. Noise immunity: EN 61000-6-2:2005, EN 61326-1:2006. UL approval: UL 61010-1, UL 61010-2-201 Load specification DC General Use / DC Pilot Duty Degree of protection not tested by UL; tested by Pepperl+Fuchs SE. Ambient temperature: -30 ... 70 °C (-22 ... 158 °F). Storage temperature: -30 ... 85 °C (-22 ... 185 °F). Relative humidity: 85 % non-condensing. Climatic conditions: For indoor use only. Altitude: ≤ 5000 m above MSL. Shock and impact resistance: 30 g, 11 ms in 6 spatial directions, 3 shocks 10 g, 16 ms in 6 spatial directions, 1000 shocks. Vibration resistance: 0.35 mm / 5 g 5 ... 500 Hz. Pollution degree: 2. Degree of protection: IP54 according to EN 60529. Connection: IO-Link: M12 round plug connector in accordance with EN 61076-2-101, LM type (4-pin, connector contacts, screw-locking, A-coded)Female connector: LF type or similarIO: M8 round plug connector in accordance with EN 61076-2-104, LF type (4-pin, bushing contacts, screw-locking, A-coded)Mating connector: LM type or similar. Mass: 310 g. Dimensions: . Height27.5 mmWidth131.5 mmLength54 mm: . Height: 27.5 mm. Width: 131.5 mm. Length: 54 mm. Mounting: 2 clips with ∅ 8 mm drill hole The module must be secured to a solid, continuous surface using the two lugs. Cable length: 1 m (IO-Link)0.2 m (IO1/2, IO15/16), 0.3 m (IO3/4, IO13/14)0.4 m (IO5/6, IO11/12); 0.5 m (IO7/8, IO9/10)max. 10 m

Specifications

General specifications

UL File NumberE223772
MTBF149 a

Indicators/operating means

LED green<--, -->: IO1..8 / IO9..16 bank indication
LED yellow/redIO1 ... IO16: inputs/outputs status, IO-Link status

Electrical specifications

Operating voltage18 ... 30 V DC, PELV Current limitation of the supply max. 4 A UB
No-load supply current≤ 25 mA I0
Operating currentmax. 4 A IB

Interface

Interface typeIO-Link
IO-Link revision1.1
Device profileIdentification and Diagnosis - I&D Firmware update
Process dataInputs 3 Byte - Input signals 16 Bit - diagnosis signals 5 Bit Outputs 2 Byte - Output signals 16 Bit
Vendor ID1 (0x0001)
Device ID985345 (0x0F0901)
Data transfer rateCOM3 (230.4 kbits/s)
Min. cycle time1 ms
SIO mode supportno
Compatible master port typeClass A

Input

Number/Type16 Inputs for 3-wire sensors (PNP), DC (IO1 ... IO16)
Supplyfrom IO-Link
Current loading capacity200 mA , overload and short-circuit protected
Input current≤ 5 mA (limited internally)
Switching pointType 3 according to IEC 61131-2

Output

Number/Type16 electronic outputs, PNP (IO1 … IO16), overload-proof and short-circuit-proof
Supplyfrom IO-Link
Voltage≥ (UB - 1.5 V)
Current200 mA per output

Directive conformity

Electromagnetic compatibility
Directive 2014/30/EUEN 61326-1:2013 EN 55011:2016 Directive 2014/30/EU
Directive 2014/30/EUEN 61326-1:2013 EN 55011:2016

Standard conformity

Degree of protectionEN 60529:2000
InputEN 61131-2:2007
Communication interfaceIEC 61131-9:2013 / IO-Link V1.1.3
Emitted interferenceEN 61000-6-4:2007
Noise immunityEN 61000-6-2:2005, EN 61326-1:2006

Approvals and certificates

UL approvalUL 61010-1, UL 61010-2-201 Load specification DC General Use / DC Pilot Duty Degree of protection not tested by UL; tested by Pepperl+Fuchs SE

Ambient conditions

Ambient temperature-30 ... 70 °C (-22 ... 158 °F)
Storage temperature-30 ... 85 °C (-22 ... 185 °F)
Relative humidity85 % non-condensing
Climatic conditionsFor indoor use only
Altitude≤ 5000 m above MSL
Shock and impact resistance30 g, 11 ms in 6 spatial directions, 3 shocks 10 g, 16 ms in 6 spatial directions, 1000 shocks
Vibration resistance0.35 mm / 5 g 5 ... 500 Hz
Pollution degree2

Mechanical specifications

Degree of protectionIP54 according to EN 60529
ConnectionIO-Link: M12 round plug connector in accordance with EN 61076-2-101, LM type (4-pin, connector contacts, screw-locking, A-coded)Female connector: LF type or similarIO: M8 round plug connector in accordance with EN 61076-2-104, LF type (4-pin, bushing contacts, screw-locking, A-coded)Mating connector: LM type or similar
Mass310 g
Dimensions
Height27.5 mmWidth131.5 mmLength54 mm Height
Height27.5 mm
Width131.5 mm
Length54 mm
Mounting2 clips with ∅ 8 mm drill hole The module must be secured to a solid, continuous surface using the two lugs
Cable length1 m (IO-Link)0.2 m (IO1/2, IO15/16), 0.3 m (IO3/4, IO13/14)0.4 m (IO5/6, IO11/12); 0.5 m (IO7/8, IO9/10)max. 10 m
12-month warrantyon all new stock
3-month warrantyon used & refurbished parts
30-day returnsno restocking fee on unused parts
Global shippingFast, tracked delivery worldwide

More Pepperl Fuchs parts

Pepperl Fuchs ICA-16DI-G60A-IOAvailable on requestPepperl Fuchs ICA-16DI-G60A-IO
MPN: ICA-16DI-G60A-IO · Pepperl Fuchs
Price on request
Request a quote
Pepperl Fuchs ICA-16DIO-G11-IO – I/O hub. I/O hub with IO-Link interface for 16 freely…Available on requestPepperl Fuchs ICA-16DIO-G11-IO – I/O hub. I/O hub with IO-Link interface for 16 freely…
MPN: ICA-16DIO-G11-IO · Pepperl Fuchs
Price on request
Request a quote
Pepperl Fuchs ICA-16DIO-G16-IO – I/O hub. I/O hub with IO-Link interface for 16 freely…Available on requestPepperl Fuchs ICA-16DIO-G16-IO – I/O hub. I/O hub with IO-Link interface for 16 freely…
MPN: ICA-16DIO-G16-IO · Pepperl Fuchs
Price on request
Request a quote
Pepperl Fuchs ICA-16DIO-G60AL-IO – I/O hub. I/O hub with IO-Link interface for 16 digital…Available on requestPepperl Fuchs ICA-16DIO-G60AL-IO – I/O hub. I/O hub with IO-Link interface for 16 digital…
MPN: ICA-16DIO-G60AL-IO · Pepperl Fuchs
Price on request
Request a quote
Pepperl Fuchs ICA-8DIO-CB10-IO – IO-Link printed circuit board module. I/O hub with IO-Link…Available on requestPepperl Fuchs ICA-8DIO-CB10-IO – IO-Link printed circuit board module. I/O hub with IO-Link…
MPN: ICA-8DIO-CB10-IO · Pepperl Fuchs
Price on request
Request a quote
Pepperl Fuchs ICA-8DIO4M1-G20-IO – IO-Link Motor Roller Module. G20 MDR module with IO-Link…Available on requestPepperl Fuchs ICA-8DIO4M1-G20-IO – IO-Link Motor Roller Module. G20 MDR module with IO-Link…
MPN: ICA-8DIO4M1-G20-IO · Pepperl Fuchs
Price on request
Request a quote
Pepperl Fuchs ICA-8IO-4M4-G20-IO-P14 – IO-Link Motor Roller Module. G20 MDR module with IO-Link…Available on requestPepperl Fuchs ICA-8IO-4M4-G20-IO-P14 – IO-Link Motor Roller Module. G20 MDR module with IO-Link…
MPN: ICA-8IO-4M4-G20-IO-P14 · Pepperl Fuchs
Price on request
Request a quote
Pepperl Fuchs ICA-AI-I/U-IO-V1 – IO-Link converter. IO-Link converter with analog input…Available on requestPepperl Fuchs ICA-AI-I/U-IO-V1 – IO-Link converter. IO-Link converter with analog input…
MPN: ICA-AI-I/U-IO-V1 · Pepperl Fuchs
Price on request
Request a quote