variable speed drive, Altivar Process ATV900, ATV950, 75kW, 400 to 480V, with braking unit, switch, IP55
Request a Quote
Quick facts
| Availability | Confirmed on request |
| Category | Altivar Process ATV900 |
| Lifecycle | active |
| Warranty | 12-month (new) · 3-month (used/refurbished) |
| Weight | 89.3 kg |
Shipping & availability
When can ATV950D75N4E be shipped?
ATV950D75N4E is sourced on request — request a quote and we'll confirm the exact availability and shipping timeline for this specific unit.
Can I pick up ATV950D75N4E in person?
Local pickup from our Groningen, Netherlands warehouse may be possible — contact us before ordering to check availability and arrange a collection time.
Is express delivery available?
Yes — mention it when you request a quote for ATV950D75N4E and we'll include express shipping options in our reply.
My factory is down and I need this urgently — can you help?
For a critical breakdown, contact us directly at +31 (0)50-7110348 or sales@partnerplc.com — we can look into same-day courier or dedicated taxi/hotshot delivery for ATV950D75N4E, subject to availability and destination.
This Altivar Process ATV900 variable speed drive can feed 3-phase synchronous and asynchronous power motors. It is suitable for motors with power rating up to 75kW/100HP for applications requiring slight overload (up to 120%). It is suitable for motors with power rating up to 55kW/75HP for applications requiring significant overload (up to 150%). It works at a rated supply voltage from 380Vac to 480Vac. This variable speed / frequency drive (VSD / VFD) is specifically designed for industrial processes. In the following market segments: oil and gas, mining, minerals and metals, food and beverage water and wastewater. It offers high motor performance on any motor and total control of any kind of coupling in master/slave applications. Network services help ensure operation continuity even in case of connection breakdown. Web server and data logging help reduce downtime through fast troubleshooting and preventive maintenance. Its advanced connectivity, including EtherNet/IP and Modbus TCP, allows deep integration into automation architectures.
Specifications
Specifications
| Range of product | Altivar Process ATV900 |
| Product specific application | Process for industrial |
| Product or component type | Variable speed drive |
| Variant | With load break switch, With braking chopper |
| Device application | Industrial application |
| Product destination | Synchronous motors, Asynchronous motors |
| Network number of phases | 3 phases |
| Mounting mode | Wall mount |
| Continuous output current | 145 A at 2.5 kHz for normal duty, 106 A at 2.5 kHz for heavy duty |
| Communication port protocol | Modbus TCP, EtherNet/IP, Modbus serial |
| option module | Slot A: communication module for Profibus DP V1, Slot A: communication module for PROFINET, Slot A: communication module for DeviceNet, Slot A: communication module for EtherCAT, Slot A: communication module for CANopen daisy chain RJ45, Slot A: communication module for CANopen SUB-D 9, Slot A: communication module for CANopen screw terminals, Slot A/slot B/slot C: digital and analog I/O extension module, Slot A/slot B/slot C: output relay extension module, Slot B: 5/12 V digital encoder interface module, Slot B: analog encoder interface module, Slot B: resolver encoder interface module, communication module for Ethernet Powerlink |
| [Us] rated supply voltage | 380...480 V |
| Relative symmetric mains voltage tolerance | 10 % |
| Relative symmetric network frequency tolerance | 5 % |
| nominal output current | 145.0 A |
| Motor power kW | 75.0 kW for normal duty, 55.0 kW for heavy duty |
| EMC filter | Integrated, With EMC plate option |
| IP degree of protection | IP55 |
| Degree of protection | UL type 1 |
| Electrical connection | Control: screw terminal 0.5...1.5 mm², Line side: screw terminal 95 mm², Motor: screw terminal 95...120 mm², DC bus: screw terminal 70...120 mm² |
| Transmission rate | 10, 100 Mbits, 4.8 kbps, 9600 bit/s, 19200 bit/s |
| Exchange mode | Half duplex, full duplex, autonegotiation Ethernet IP/Modbus TCP |
| Data format | 8 bits, configurable odd, even or no parity |
| Type of polarization | No impedance |
| Number of addresses | 1…247 |
| Supply | External supply for digital inputs: 24 V DC (19…30 V), <1.25 mA, protection type: overload and short-circuit protection, Internal supply for reference potentiometer (1 to 10 kOhm): 10.5 V DC +/- 5 %, <10 mA, protection type: overload and short-circuit protection, Internal supply for digital inputs and STO: 24 V DC (21…27 V), <200 mA, protection type: overload and short-circuit protection |
| Local signalling | Local diagnostic: 3 LED (mono/dual colour), Embedded communication status: 5 LED (dual colour), Communication module status: 2 LED (dual colour), Presence of voltage: 1 LED (red) |
| Input compatibility | DI1...DI8: discrete input level 1 PLC conforming to IEC 61131-2, DI7, DI8: pulse input level 1 PLC conforming to IEC 65A-68, STOA, STOB: discrete input level 1 PLC conforming to IEC 61131-2 |
| Discrete input logic | 16 preset speeds |
| Sampling duration | 2 ms +/- 0.5 ms (DI1...DI8) - discrete input, 5 ms +/- 1 ms (DI7, DI8) - pulse input, 1 ms +/- 1 ms (AI1, AI2, AI3) - analog input, 5 ms +/- 1 ms (AQ1, AQ2) - analog output |
| Accuracy | +/- 0.6 % AI1, AI2, AI3 for a temperature variation 60 °C analog input, +/- 1 % AQ1, AQ2 for a temperature variation 60 °C analog output |
| Linearity error | AI1, AI2, AI3: +/- 0.15 % of maximum value for analog input, AQ1, AQ2: +/- 0.2 % for analog output |
| Refresh time | Relay output (R1, R2, R3): 5 ms (+/- 0.5 ms) |
| Isolation | Between power and control terminals |
| Discrete input number | 10 |
| Discrete input type | DI1...DI8 programmable, 24 V DC (<= 30 V), impedance: 3.5 kOhm, DI7, DI8 programmable as pulse input: 0…30 kHz, 24 V DC (<= 30 V), STOA, STOB safe torque off, 24 V DC (<= 30 V), impedance: > 2.2 kOhm |
| Discrete output number | 2 |
| Discrete output type | Logic output DQ+ 0…1 kHz <= 30 V DC 100 mA, Programmable as pulse output DQ+ 0…30 kHz <= 30 V DC 20 mA, Logic output DQ- 0…1 kHz <= 30 V DC 100 mA |
| Analogue input number | 3 |
| Analogue input type | AI1, AI2, AI3 software-configurable voltage: 0...10 V DC, impedance: 30 kOhm, resolution 12 bits, AI1, AI2, AI3 software-configurable current: 0...20 mA/4...20 mA, impedance: 250 Ohm, resolution 12 bits |
| Analogue output number | 2 |
| Analogue output type | Software-configurable voltage AQ1, AQ2: 0...10 V DC impedance 470 Ohm, resolution 10 bits, Software-configurable current AQ1, AQ2: 0...20 mA impedance 500 Ohm, resolution 10 bits |
| Relay output number | 3 |
| Relay output type | Configurable relay logic R1: fault relay NO/NC electrical durability 100000 cycles, Configurable relay logic R2: sequence relay NO electrical durability 1000000 cycles, Configurable relay logic R3: sequence relay NO electrical durability 1000000 cycles |
| Maximum switching current | Relay output R1 on resistive load, cos phi = 1: 3 A at 250 V AC, Relay output R1 on resistive load, cos phi = 1: 3 A at 30 V DC, Relay output R1 on inductive load, cos phi = 0.4 and L/R = 7 ms: 2 A at 250 V AC, Relay output R1 on inductive load, cos phi = 0.4 and L/R = 7 ms: 2 A at 30 V DC, Relay output R2, R3 on resistive load, cos phi = 1: 5 A at 250 V AC, Relay output R2, R3 on resistive load, cos phi = 1: 5 A at 30 V DC, Relay output R2, R3 on inductive load, cos phi = 0.4 and L/R = 7 ms: 2 A at 250 V AC, Relay output R2, R3 on inductive load, cos phi = 0.4 and L/R = 7 ms: 2 A at 30 V DC |
| Minimum switching current | Relay output R1, R2, R3: 5 mA at 24 V DC |
| Physical interface | Ethernet, 2-wire RS 485 |
| Connector type | 2 RJ45, 1 RJ45 |
| Method of access | Slave Modbus TCP |
| Transmission frame | RTU |
| 4 quadrant operation possible | True |
| Asynchronous motor control profile | Variable torque standard, Optimized torque mode, Constant torque standard |
| Synchronous motor control profile | Permanent magnet motor, Synchronous reluctance motor |
| Maximum output frequency | 599 Hz |
| Acceleration and deceleration ramps | Linear adjustable separately from 0.01...9999 s |
| Motor slip compensation | Adjustable, Not available in permanent magnet motor law, Automatic whatever the load, Can be suppressed |
| Switching frequency | 1...8 kHz adjustable, 2.5...8 kHz with derating factor |
| Nominal switching frequency | 2.5 kHz |
| Braking to standstill | By DC injection |
| Brake chopper integrated | True |
| Line current | 131.3 A at 380 V (normal duty), 98.9 A at 380 V (heavy duty), 112.7 A at 480 V (normal duty), 86.9 A at 480 V (heavy duty) |
| Maximum input current | 131.3 A |
| Maximum output voltage | 480.0 V |
| Apparent power | 93.7 kVA at 480 V (normal duty), 72.2 kVA at 480 V (heavy duty) |
| Maximum transient current | 174 A during 60 s (normal duty), 159 A during 60 s (heavy duty) |
| Network frequency | 50...60 Hz |
| Prospective line Isc | 50 kA |
| Base load current at high overload | 106.0 A |
| Base load current at low overload | 145.0 A |
| With safety function Safely Limited Speed (SLS) | True |
| With safety function Safe brake management (SBC/SBT) | True |
| With safety function Safe Operating Stop (SOS) | False |
| With safety function Safe Position (SP) | False |
| With safety function Safe programmable logic | False |
| With safety function Safe Speed Monitor (SSM) | False |
| With safety function Safe Stop 1 (SS1) | True |
| With sft fct Safe Stop 2 (SS2) | False |
| With safety function Safe torque off (STO) | True |
| With safety function Safely Limited Position (SLP) | False |
| With safety function Safe Direction (SDI) | False |
| Protection type | Thermal protection: motor, Safe torque off: motor, Motor phase break: motor, Thermal protection: drive, Safe torque off: drive, Overheating: drive, Overcurrent between output phases and earth: drive, Overload of output voltage: drive, Short-circuit protection: drive, Motor phase break: drive, Overvoltages on the DC bus: drive, Line supply overvoltage: drive, Line supply undervoltage: drive, Line supply phase loss: drive, Overspeed: drive, Break on the control circuit: drive |
| Quantity per set | 1 |
| Width | 345 mm |
| Height | 1250 mm |
| Depth | 436 mm |
| Net weight | 89.3 kg |
| Insulation resistance | > 1 MOhm 500 V DC for 1 minute to earth |
| Noise level | 69.9 dB |
| Vibration resistance | 1.5 mm peak to peak (f= 2…13 Hz) conforming to IEC 60068-2-6, 1 gn (f= 13…200 Hz) conforming to IEC 60068-2-6 |
| Shock resistance | 15 gn for 11 ms conforming to IEC 60068-2-27 |
| Environmental characteristic | Chemical pollution resistance class 3C3 conforming to IEC 60721-3-3, Dust pollution resistance class 3S3 conforming to IEC 60721-3-3 |
| Relative humidity | 5…95 % without condensation conforming to IEC 60068-2-3 |
| Ambient air temperature for operation | -15…40 °C (without derating), 40…50 °C (with derating factor) |
| Operating altitude | <= 1000 m without derating, 1000...4800 m with current derating 1 % per 100 m |
| Operating position | Vertical +/- 10 degree |
| Product certifications | TÜV |
| Marking | CE |
| Standards | UL 508C, IEC 61800-3, IEC 61800-5-1, IEC 61000-3-12, IEC 60721-3, IEC 61508, IEC 13849-1 |
| Maximum THDI | <48 % from 80...100 % of load conforming to IEC 61000-3-12 |
| Assembly style | Enclosed |
| Electromagnetic compatibility | Electrostatic discharge immunity test level 3 conforming to IEC 61000-4-2, Radiated radio-frequency electromagnetic field immunity test level 3 conforming to IEC 61000-4-3, Electrical fast transient/burst immunity test level 4 conforming to IEC 61000-4-4, 1.2/50 µs - 8/20 µs surge immunity test level 3 conforming to IEC 61000-4-5, Conducted radio-frequency immunity test level 3 conforming to IEC 61000-4-6 |
| Environmental class (during operation) | Class 3C3 according to IEC 60721-3-3, Class 3S3 according to IEC 60721-3-3 |
| Maximum acceleration under shock impact (during operation) | 150 m/s² at 11 ms |
| Maximum acceleration under vibrational stress (during operation) | 10 m/s² at 13...200 Hz |
| Maximum deflection under vibratory load (during operation) | 1.5 mm at 2...13 Hz |
| Permitted relative humidity (during operation) | Class 3K5 according to EN 60721-3 |
| Overvoltage category | III |
| Regulation loop | Adjustable PID regulator |
| Pollution degree | 2 |
| Ambient air transport temperature | -40…70 °C |
| Ambient air temperature for storage | -40…70 °C |
| Unit Type of Package 1 | PCE |
| Number of Units in Package 1 | 1 |
| Package 1 Height | 55.0 cm |
| Package 1 Width | 48.0 cm |
| Package 1 Length | 143.0 cm |
| Package 1 Weight | 102.0 kg |
| Warranty (in months) | 18 |