Pepperl Fuchs WHA-BLT-F9D0-N-A0-Z1-1 – Bullet WirelessHART Adapter. Installation in Zone 1, 21
Request a Quote
Quick facts
| Availability | Confirmed on request |
| Category | Accessories |
| Lifecycle | Active |
| Warranty | 12-month (new) · 3-month (used/refurbished) |
Shipping & availability
When can WHA-BLT-F9D0-N-A0-Z1-1 be shipped?
WHA-BLT-F9D0-N-A0-Z1-1 is sourced on request — request a quote and we'll confirm the exact availability and shipping timeline for this specific unit.
Can I pick up WHA-BLT-F9D0-N-A0-Z1-1 in person?
Local pickup from our Groningen, Netherlands warehouse may be possible — contact us before ordering to check availability and arrange a collection time.
Is express delivery available?
Yes — mention it when you request a quote for WHA-BLT-F9D0-N-A0-Z1-1 and we'll include express shipping options in our reply.
My factory is down and I need this urgently — can you help?
For a critical breakdown, contact us directly at +31 (0)50-7110348 or sales@partnerplc.com — we can look into same-day courier or dedicated taxi/hotshot delivery for WHA-BLT-F9D0-N-A0-Z1-1, subject to availability and destination.
Bullet WirelessHART Adapter. Installation in Zone 1, 21, Installation in Class I, II, Division 1, Installation in Class III, Ex d housing for Ex d field devices, Cast aluminum housing, Loop powered, Direct mounting on HART or 4 mA ... 20 mA field device, Encapsulated antenna, Up to 8 field devices in multidrop. Rated voltage: 7 ... 32 V DC. Rated current: < 1 mA , max. 25 mA. Output current: 3.2 ... 25 mA. Supply: loop power for field devicesvoltage: 1 ... 2.5 V DC, adjustable in steps of 0.5 V. Connection: - 5 wires, 600 mm long, exiting from male thread NPT1/2 - 1 external grounding point. HART communication: . ProtocolHART 7.1, backward compatibleNumber of devicesup to 8 HART field devices (depending on installation): . Protocol: HART 7.1, backward compatible. Number of devices: up to 8 HART field devices (depending on installation). Interface: internal antenna. Communication: WirelessHART specifications- physical layer: IEEE 802.15.4.2006- frequency band: 2.4 GHz (ISM band, licence free)- maximum transmit power: +10 dBm- outdoor transmission range: 235 m- communication standard: WirelessHART acc. to IEC 62591. Radio and telecommunication terminal equipment: The usage of 2.4 GHz equipment is bound to local restrictions. Ensure that restrictions allow usage of this product before commisioning.. Directive 2014/53/EUEN 300 328 V2.1.1:2016 EN 301 489-1 V2.2.0:2017 EN 301 489-17 V3.2.0:2017FCC CFR47 Part 15 B and CANSI C63.4-2003 , FCC ID: X89-WA1101: . Directive 2014/53/EU: EN 300 328 V2.1.1:2016 EN 301 489-1 V2.2.0:2017 EN 301 489-17 V3.2.0:2017. FCC CFR47 Part 15 B and C: ANSI C63.4-2003 , FCC ID: X89-WA1101. Degree of protection: IEC 60529:2013. Ambient temperature: temperature class T5: -40 ... 85 °C (-40 ... 185 °F) temperature class T6: -40 ... 75 °C (-40 ... 167 °F). Storage temperature: -40 ... 85 °C (-40 ... 185 °F). Relative humidity: max. 100 %. Degree of protection: IP67. Material: aluminum alloy with polyurethane enamel paint. Mass: 460 g. Dimensions: 60.8 x 60.8 x 100 mm (l x w x h). Height100 mmDiameter60.8 mm: . Height: 100 mm. Diameter: 60.8 mm. EU-type examination certificate: FM 17 ATEX 0046 X. Marking II 2 G Ex db IIC T6...T5 Gb [exsign] II 2 D Ex tb IIIC T95°C Db: . Marking: II 2 G Ex db IIC T6...T5 Gb [exsign] II 2 D Ex tb IIIC T95°C Db. Directive conformity: . Directive 2014/34/EUEN 60079-0:2012+A11:2013 , EN 60079-1:2014 , EN 60079-31:2014: . Directive 2014/34/EU: EN 60079-0:2012+A11:2013 , EN 60079-1:2014 , EN 60079-31:2014. FM approval: FM 17 NUS 0010 FM 17 US 0191 X. Control drawing116-0425 (cFMus)Approved forXP Class I, II, III, Division 1, Groups A-G Class I, Zone 1, AEx db IIC T6...T5 Gb Zone 21, AEx tb IIIC T95°C Db: . Control drawing: 116-0425 (cFMus). Approved for: XP Class I, II, III, Division 1, Groups A-G Class I, Zone 1, AEx db IIC T6...T5 Gb Zone 21, AEx tb IIIC T95°C Db. CSA approval: FM 17 NCA 0004 FM 17 CA 0102 X. Control drawing116-0425 (cFMus)Approved forXP Class I, II, III, Division 1, Groups A-G Ex db IIC T6...T5 Gb Ex tb IIIC T95°C Db: . Control drawing: 116-0425 (cFMus). Approved for: XP Class I, II, III, Division 1, Groups A-G Ex db IIC T6...T5 Gb Ex tb IIIC T95°C Db. IECEx approval: . IECEx certificateIECEx FMG 17.0020XIECEx markingEx db IIC T6...T5 Gb , Ex tb IIIC T95°C DbStandardsIEC 60079-0:2011 , IEC 60079-1:2014 , IEC 60079-31:2013: . IECEx certificate: IECEx FMG 17.0020X. IECEx marking: Ex db IIC T6...T5 Gb , Ex tb IIIC T95°C Db. Standards: IEC 60079-0:2011 , IEC 60079-1:2014 , IEC 60079-31:2013. Supplementary information: Observe the certificates, declarations of conformity, instruction manuals, and manuals where applicable. For information see www.pepperl-fuchs.com.
Specifications
Supply
| Rated voltage | 7 ... 32 V DC Ur |
| Rated current | < 1 mA , max. 25 mA Ir |
Electrical specifications
| Output current | 3.2 ... 25 mA |
| Supply | loop power for field devicesvoltage: 1 ... 2.5 V DC, adjustable in steps of 0.5 V |
Input
| Connection | - 5 wires, 600 mm long, exiting from male thread NPT1/2 - 1 external grounding point |
| HART communication | |
| ProtocolHART 7.1, backward compatibleNumber of devicesup to 8 HART field devices (depending on installation) | Protocol |
| Protocol | HART 7.1, backward compatible |
| Number of devices | up to 8 HART field devices (depending on installation) |
Output
| Interface | internal antenna |
| Communication | WirelessHART specifications- physical layer: IEEE 802.15.4.2006- frequency band: 2.4 GHz (ISM band, licence free)- maximum transmit power: +10 dBm- outdoor transmission range: 235 m- communication standard: WirelessHART acc. to IEC 62591 |
Directive conformity
| Radio and telecommunication terminal equipment | The usage of 2.4 GHz equipment is bound to local restrictions. Ensure that restrictions allow usage of this product before commisioning. |
| Directive 2014/53/EUEN 300 328 V2.1.1:2016 EN 301 489-1 V2.2.0:2017 EN 301 489-17 V3.2.0:2017FCC CFR47 Part 15 B and CANSI C63.4-2003 , FCC ID: X89-WA1101 | Directive 2014/53/EU |
| Directive 2014/53/EU | EN 300 328 V2.1.1:2016 EN 301 489-1 V2.2.0:2017 EN 301 489-17 V3.2.0:2017 |
| FCC CFR47 Part 15 B and C | ANSI C63.4-2003 , FCC ID: X89-WA1101 |
Conformity
| Degree of protection | IEC 60529:2013 |
Ambient conditions
| Ambient temperature | temperature class T5: -40 ... 85 °C (-40 ... 185 °F) temperature class T6: -40 ... 75 °C (-40 ... 167 °F) |
| Storage temperature | -40 ... 85 °C (-40 ... 185 °F) |
| Relative humidity | max. 100 % |
Mechanical specifications
| Degree of protection | IP67 |
| Material | aluminum alloy with polyurethane enamel paint |
| Mass | 460 g |
| Dimensions | 60.8 x 60.8 x 100 mm (l x w x h) |
| Height100 mmDiameter60.8 mm | Height |
| Height | 100 mm |
| Diameter | 60.8 mm |
Data for application in connection with hazardous areas
| EU-type examination certificate | FM 17 ATEX 0046 X |
| Marking II 2 G Ex db IIC T6...T5 Gb [exsign] II 2 D Ex tb IIIC T95°C Db | Marking |
| Marking | II 2 G Ex db IIC T6...T5 Gb [exsign] II 2 D Ex tb IIIC T95°C Db |
| Directive conformity | |
| Directive 2014/34/EUEN 60079-0:2012+A11:2013 , EN 60079-1:2014 , EN 60079-31:2014 | Directive 2014/34/EU |
| Directive 2014/34/EU | EN 60079-0:2012+A11:2013 , EN 60079-1:2014 , EN 60079-31:2014 |
International approvals
| FM approval | FM 17 NUS 0010 FM 17 US 0191 X |
| Control drawing116-0425 (cFMus)Approved forXP Class I, II, III, Division 1, Groups A-G Class I, Zone 1, AEx db IIC T6...T5 Gb Zone 21, AEx tb IIIC T95°C Db | Control drawing |
| Control drawing | 116-0425 (cFMus) |
| Approved for | XP Class I, II, III, Division 1, Groups A-G Class I, Zone 1, AEx db IIC T6...T5 Gb Zone 21, AEx tb IIIC T95°C Db |
| CSA approval | FM 17 NCA 0004 FM 17 CA 0102 X |
| Control drawing116-0425 (cFMus)Approved forXP Class I, II, III, Division 1, Groups A-G Ex db IIC T6...T5 Gb Ex tb IIIC T95°C Db | Control drawing |
| Control drawing | 116-0425 (cFMus) |
| Approved for | XP Class I, II, III, Division 1, Groups A-G Ex db IIC T6...T5 Gb Ex tb IIIC T95°C Db |
| IECEx approval | |
| IECEx certificateIECEx FMG 17.0020XIECEx markingEx db IIC T6...T5 Gb , Ex tb IIIC T95°C DbStandardsIEC 60079-0:2011 , IEC 60079-1:2014 , IEC 60079-31:2013 | IECEx certificate |
| IECEx certificate | IECEx FMG 17.0020X |
| IECEx marking | Ex db IIC T6...T5 Gb , Ex tb IIIC T95°C Db |
| Standards | IEC 60079-0:2011 , IEC 60079-1:2014 , IEC 60079-31:2013 |
General information
| Supplementary information | Observe the certificates, declarations of conformity, instruction manuals, and manuals where applicable. For information see www.pepperl-fuchs.com. |
More Pepperl Fuchs parts
Available on requestPepperl Fuchs Wetterhaube AIR30
Available on requestPepperl Fuchs Wetterschutzhaube PIR 20 – Mounting aid DGE. Protection from adverse effects of…
Available on requestPepperl Fuchs WHA-BLT-F9D0-N-A0-GP-1 – Bullet WirelessHART Adapter. Cast aluminum housing
Available on requestPepperl Fuchs WHA-BLT-F9D0-N-A0-Z0-Ex1 – Bullet WirelessHART Adapter. Installation in Zone 0, 20
Available on requestPepperl Fuchs Wrist strap – Hand strap. Hand strap for universal use. Color: black.…
Available on requestPepperl Fuchs WS-UCC2500-F406-B41-01-02-IBC
Available on requestPepperl Fuchs WS-VAL-2N-F406-B41-01-02
Available on requestPepperl Fuchs WS-VAL-2N4-F406-B41-01-02