Available on request

Pepperl Fuchs WHA-BLT-F9D0-N-A0-Z0-Ex1 – Bullet WirelessHART Adapter. Installation in Zone 0, 20

MPN: WHA-BLT-F9D0-N-A0-Z0-Ex1 · Brand: Pepperl Fuchs
Price on request
Request a Quote

A real person replies, typically within 1 business day — see our privacy policy.

12-month warranty (new) · 3-month (used/refurbished)
30-day returns, no restocking fee on unused parts
Ships via

Quick facts

AvailabilityConfirmed on request
CategoryAccessories
LifecycleActive
Warranty12-month (new) · 3-month (used/refurbished)

Shipping & availability

When can WHA-BLT-F9D0-N-A0-Z0-Ex1 be shipped?

WHA-BLT-F9D0-N-A0-Z0-Ex1 is sourced on request — request a quote and we'll confirm the exact availability and shipping timeline for this specific unit.

Can I pick up WHA-BLT-F9D0-N-A0-Z0-Ex1 in person?

Local pickup from our Groningen, Netherlands warehouse may be possible — contact us before ordering to check availability and arrange a collection time.

Is express delivery available?

Yes — mention it when you request a quote for WHA-BLT-F9D0-N-A0-Z0-Ex1 and we'll include express shipping options in our reply.

My factory is down and I need this urgently — can you help?

For a critical breakdown, contact us directly at +31 (0)50-7110348 or sales@partnerplc.com — we can look into same-day courier or dedicated taxi/hotshot delivery for WHA-BLT-F9D0-N-A0-Z0-Ex1, subject to availability and destination.

Bullet WirelessHART Adapter. Installation in Zone 0, 20, Installation in Class I, II, Division 1, Installation in Class III, Installation in Class I, Division 2, Ex i circuits for Ex i field devices, Cast aluminum housing, Loop powered, Direct mounting on HART or 4 mA ... 20 mA field device, Encapsulated antenna, Up to 8 field devices in multidrop. Rated voltage: 7 ... 30 V DC. Rated current: < 1 mA , max. 25 mA. Output current: 3.2 ... 25 mA. Supply: loop power for field devicesvoltage: 1 ... 2.5 V DC, adjustable in steps of 0.5 V. Connection: - 5 wires, 600 mm long, exiting from male thread NPT1/2 - 1 external grounding point. HART communication: . ProtocolHART 7.1, backward compatibleNumber of devicesup to 8 HART field devices (depending on installation): . Protocol: HART 7.1, backward compatible. Number of devices: up to 8 HART field devices (depending on installation). Interface: internal antenna. Communication: WirelessHART specifications- physical layer: IEEE 802.15.4.2006- frequency band: 2.4 GHz (ISM band, licence free)- maximum transmit power: +10 dBm- outdoor transmission range: 235 m- communication standard: WirelessHART acc. to IEC 62591. Radio and telecommunication terminal equipment: The usage of 2.4 GHz equipment is bound to local restrictions. Ensure that restrictions allow usage of this product before commisioning.. Directive 2014/53/EUEN 300 328 V2.1.1:2016 EN 301 489-1 V2.2.0:2017 EN 301 489-17 V3.2.0:2017FCC CFR47 Part 15 B and CANSI C63.4-2003 , FCC ID: X89-WA1101: . Directive 2014/53/EU: EN 300 328 V2.1.1:2016 EN 301 489-1 V2.2.0:2017 EN 301 489-17 V3.2.0:2017. FCC CFR47 Part 15 B and C: ANSI C63.4-2003 , FCC ID: X89-WA1101. Degree of protection: IEC 60529:2013. Ambient temperature: temperature class T5: -40 ... 85 °C (-40 ... 185 °F) temperature class T6: -40 ... 75 °C (-40 ... 167 °F). Storage temperature: -40 ... 85 °C (-40 ... 185 °F). Relative humidity: max. 100 %. Degree of protection: IP67. Material: aluminum alloy with polyurethane enamel paint. Mass: 460 g. Dimensions: 60.8 x 60.8 x 100 mm (l x w x h). Height100 mmDiameter60.8 mm: . Height: 100 mm. Diameter: 60.8 mm. EU-type examination certificate: FM 17 ATEX 0046 X. Marking II 1G Ex ia IIC T6...T5 Ga [exsign] II 1D Ex ia IIIC T95°C Da: . Marking: II 1G Ex ia IIC T6...T5 Ga [exsign] II 1D Ex ia IIIC T95°C Da. Directive conformity: . Directive 2014/34/EUEN 60079-0:2012+A11:2013 , EN 60079-11:2012: . Directive 2014/34/EU: EN 60079-0:2012+A11:2013 , EN 60079-11:2012. FM approval: FM 17 NUS 0010 FM 17 US 0191 X. Control drawing116-0425 (cFMus)Approved forIS Class I, II, III, Division 1, Groups A-G Class I, Zone 0, AEx ia IIC T6...T5 Ga Zone 20, AEx ia IIIC T95°C Da: . Control drawing: 116-0425 (cFMus). Approved for: IS Class I, II, III, Division 1, Groups A-G Class I, Zone 0, AEx ia IIC T6...T5 Ga Zone 20, AEx ia IIIC T95°C Da. CSA approval: FM 17 NCA 0004 FM 17 CA 0102 X. Control drawing116-0425 (cFMus)Approved forIS Class I, II, III, Division 1, Groups A-G Ex ia IIC T6...T5 Ga Ex ia IIIC T95°C Da associated apparatus [Ex ia]: . Control drawing: 116-0425 (cFMus). Approved for: IS Class I, II, III, Division 1, Groups A-G Ex ia IIC T6...T5 Ga Ex ia IIIC T95°C Da associated apparatus [Ex ia]. IECEx approval: . IECEx certificateIECEx FMG 17.0020XIECEx markingEx ia IIC T6...T5 Ga , Ex ia IIIC T95°C DaStandardsIEC 60079-0:2011 , IEC 60079-1:2014 , IEC 60079-11:2011 , IEC 60079-31:2013: . IECEx certificate: IECEx FMG 17.0020X. IECEx marking: Ex ia IIC T6...T5 Ga , Ex ia IIIC T95°C Da. Standards: IEC 60079-0:2011 , IEC 60079-1:2014 , IEC 60079-11:2011 , IEC 60079-31:2013. Supplementary information: Observe the certificates, declarations of conformity, instruction manuals, and manuals where applicable. For information see www.pepperl-fuchs.com.

Specifications

Supply

Rated voltage7 ... 30 V DC Ur
Rated current< 1 mA , max. 25 mA Ir

Electrical specifications

Output current3.2 ... 25 mA
Supplyloop power for field devicesvoltage: 1 ... 2.5 V DC, adjustable in steps of 0.5 V

Input

Connection- 5 wires, 600 mm long, exiting from male thread NPT1/2 - 1 external grounding point
HART communication
ProtocolHART 7.1, backward compatibleNumber of devicesup to 8 HART field devices (depending on installation) Protocol
ProtocolHART 7.1, backward compatible
Number of devicesup to 8 HART field devices (depending on installation)

Output

Interfaceinternal antenna
CommunicationWirelessHART specifications- physical layer: IEEE 802.15.4.2006- frequency band: 2.4 GHz (ISM band, licence free)- maximum transmit power: +10 dBm- outdoor transmission range: 235 m- communication standard: WirelessHART acc. to IEC 62591

Directive conformity

Radio and telecommunication terminal equipmentThe usage of 2.4 GHz equipment is bound to local restrictions. Ensure that restrictions allow usage of this product before commisioning.
Directive 2014/53/EUEN 300 328 V2.1.1:2016 EN 301 489-1 V2.2.0:2017 EN 301 489-17 V3.2.0:2017FCC CFR47 Part 15 B and CANSI C63.4-2003 , FCC ID: X89-WA1101 Directive 2014/53/EU
Directive 2014/53/EUEN 300 328 V2.1.1:2016 EN 301 489-1 V2.2.0:2017 EN 301 489-17 V3.2.0:2017
FCC CFR47 Part 15 B and CANSI C63.4-2003 , FCC ID: X89-WA1101

Conformity

Degree of protectionIEC 60529:2013

Ambient conditions

Ambient temperaturetemperature class T5: -40 ... 85 °C (-40 ... 185 °F) temperature class T6: -40 ... 75 °C (-40 ... 167 °F)
Storage temperature-40 ... 85 °C (-40 ... 185 °F)
Relative humiditymax. 100 %

Mechanical specifications

Degree of protectionIP67
Materialaluminum alloy with polyurethane enamel paint
Mass460 g
Dimensions60.8 x 60.8 x 100 mm (l x w x h)
Height100 mmDiameter60.8 mm Height
Height100 mm
Diameter60.8 mm

Data for application in connection with hazardous areas

EU-type examination certificateFM 17 ATEX 0046 X
Marking II 1G Ex ia IIC T6...T5 Ga [exsign] II 1D Ex ia IIIC T95°C Da Marking
MarkingII 1G Ex ia IIC T6...T5 Ga [exsign] II 1D Ex ia IIIC T95°C Da
Directive conformity
Directive 2014/34/EUEN 60079-0:2012+A11:2013 , EN 60079-11:2012 Directive 2014/34/EU
Directive 2014/34/EUEN 60079-0:2012+A11:2013 , EN 60079-11:2012

International approvals

FM approvalFM 17 NUS 0010 FM 17 US 0191 X
Control drawing116-0425 (cFMus)Approved forIS Class I, II, III, Division 1, Groups A-G Class I, Zone 0, AEx ia IIC T6...T5 Ga Zone 20, AEx ia IIIC T95°C Da Control drawing
Control drawing116-0425 (cFMus)
Approved forIS Class I, II, III, Division 1, Groups A-G Class I, Zone 0, AEx ia IIC T6...T5 Ga Zone 20, AEx ia IIIC T95°C Da
CSA approvalFM 17 NCA 0004 FM 17 CA 0102 X
Control drawing116-0425 (cFMus)Approved forIS Class I, II, III, Division 1, Groups A-G Ex ia IIC T6...T5 Ga Ex ia IIIC T95°C Da associated apparatus [Ex ia] Control drawing
Control drawing116-0425 (cFMus)
Approved forIS Class I, II, III, Division 1, Groups A-G Ex ia IIC T6...T5 Ga Ex ia IIIC T95°C Da associated apparatus [Ex ia]
IECEx approval
IECEx certificateIECEx FMG 17.0020XIECEx markingEx ia IIC T6...T5 Ga , Ex ia IIIC T95°C DaStandardsIEC 60079-0:2011 , IEC 60079-1:2014 , IEC 60079-11:2011 , IEC 60079-31:2013 IECEx certificate
IECEx certificateIECEx FMG 17.0020X
IECEx markingEx ia IIC T6...T5 Ga , Ex ia IIIC T95°C Da
StandardsIEC 60079-0:2011 , IEC 60079-1:2014 , IEC 60079-11:2011 , IEC 60079-31:2013

General information

Supplementary informationObserve the certificates, declarations of conformity, instruction manuals, and manuals where applicable. For information see www.pepperl-fuchs.com.
12-month warrantyon all new stock
3-month warrantyon used & refurbished parts
30-day returnsno restocking fee on unused parts
Global shippingFast, tracked delivery worldwide

More Pepperl Fuchs parts

Pepperl Fuchs Weather Cap for REF-C110-2 – Mounting aid DGE. Weather hood for series reflectorAvailable on requestPepperl Fuchs Weather Cap for REF-C110-2 – Mounting aid DGE. Weather hood for series reflector
MPN: Weather Cap for REF-C110-2 · Pepperl Fuchs
Price on request
Request a quote
Pepperl Fuchs Wetterhaube AIR30Available on requestPepperl Fuchs Wetterhaube AIR30
MPN: Wetterhaube AIR30 · Pepperl Fuchs
Price on request
Request a quote
Pepperl Fuchs Wetterschutzhaube PIR 20 – Mounting aid DGE. Protection from adverse effects of…Available on requestPepperl Fuchs Wetterschutzhaube PIR 20 – Mounting aid DGE. Protection from adverse effects of…
MPN: Wetterschutzhaube PIR 20 · Pepperl Fuchs
Price on request
Request a quote
Pepperl Fuchs WHA-BLT-F9D0-N-A0-GP-1 – Bullet WirelessHART Adapter. Cast aluminum housingAvailable on requestPepperl Fuchs WHA-BLT-F9D0-N-A0-GP-1 – Bullet WirelessHART Adapter. Cast aluminum housing
MPN: WHA-BLT-F9D0-N-A0-GP-1 · Pepperl Fuchs
Price on request
Request a quote
Pepperl Fuchs WHA-BLT-F9D0-N-A0-Z1-1 – Bullet WirelessHART Adapter. Installation in Zone 1, 21Available on requestPepperl Fuchs WHA-BLT-F9D0-N-A0-Z1-1 – Bullet WirelessHART Adapter. Installation in Zone 1, 21
MPN: WHA-BLT-F9D0-N-A0-Z1-1 · Pepperl Fuchs
Price on request
Request a quote
Pepperl Fuchs Wrist strap – Hand strap. Hand strap for universal use. Color: black.…Available on requestPepperl Fuchs Wrist strap – Hand strap. Hand strap for universal use. Color: black.…
MPN: Wrist strap · Pepperl Fuchs
Price on request
Request a quote
Pepperl Fuchs WS-UCC2500-F406-B41-01-02-IBCAvailable on requestPepperl Fuchs WS-UCC2500-F406-B41-01-02-IBC
MPN: WS-UCC2500-F406-B41-01-02-IBC · Pepperl Fuchs
Price on request
Request a quote
Pepperl Fuchs WS-VAL-2N-F406-B41-01-02Available on requestPepperl Fuchs WS-VAL-2N-F406-B41-01-02
MPN: WS-VAL-2N-F406-B41-01-02 · Pepperl Fuchs
Price on request
Request a quote