Pepperl Fuchs WCS3B-LS810DHS-OM
Request a Quote
Quick facts
| Availability | Confirmed on request |
| Category | Optical Linear Positioning Systems |
| Lifecycle | active |
| Warranty | 12-month (new) · 3-month (used/refurbished) |
Shipping & availability
When can WCS3B-LS810DHS-OM be shipped?
WCS3B-LS810DHS-OM is sourced on request — request a quote and we'll confirm the exact availability and shipping timeline for this specific unit.
Can I pick up WCS3B-LS810DHS-OM in person?
Local pickup from our Groningen, Netherlands warehouse may be possible — contact us before ordering to check availability and arrange a collection time.
Is express delivery available?
Yes — mention it when you request a quote for WCS3B-LS810DHS-OM and we'll include express shipping options in our reply.
My factory is down and I need this urgently — can you help?
For a critical breakdown, contact us directly at +31 (0)50-7110348 or sales@partnerplc.com — we can look into same-day courier or dedicated taxi/hotshot delivery for WCS3B-LS810DHS-OM, subject to availability and destination.
Read head. Read head, IO-Link interface, IO-Link interface for service and process data, Non-contact, absolute position encoder, Automatic detection of dirt accumulation, Integrated display module, Extended temperature range, For outdoor use, Output of position and speed, Acceleration measurement in 3 axis, Output of the ID number for ID pads. Passage speed: ≤ 12.5 m/s. Measuring length: max. 314.5 m. Free tolerances to code rail: horizontal: 31 mm ( ± 15.5 mm )vertical: 28 mm ( ± 14 mm ). Resolution: ± 0.4 mm (1,250 positions/m). MTTFd: 40 a. Mission Time (TM): 10 a. Diagnostic Coverage (DC): 0 %. Operation indicator: LED green:constantly on - power onflashing - IO-Link mode. Data flow indicator: LED yellow: data communication active. Error indicator: LED red flashing: read head outside of code rail solid on: internal diagnostic test failed. Display: Display module, 6-digit , adaptable to installation position. Operating voltage: 18 ... 30 V DC. Power consumption: 12 VA. Interface type: IO-Link. IO-Link revision: 1.1. Device profile: Identification and Diagnosis - I&D Firmware update. Process data: Input: 18 Byte - Position value 32 Bit - Velocity value 16 Bit - Acceleration values 3 x 16 Bit - Ident number 16 Bit - Heartbeat 8 Bit - status data 24 Bit output: 1 Byte - control signals 8 Bit. Vendor ID: 1 (0x0001). Device ID: 6291713 (0x600101). Transfer rate: COM3 (230.4 kbits/s). Min. cycle time: 1.5 ms. SIO mode support: no. Compatible master port type: Class A. Communication interface: IEC 61131-9 / IO-Link V1.1.3. Emitted interference: DIN EN 61000-6-4 , DIN EN 12015. Noise immunity: DIN EN 61000-6-2 , DIN EN 12016. Shock resistance: DIN EN 60068-2-27, half sine 30 g, 18 ms. Vibration resistance: DIN EN 60068-2-6, sine, 5 g, 10 - 2000 Hz, 10 cycles. CSA approval: cCSAus Certified, General Purpose Class 2 power source. CCC approval: CCC approval / marking not required for products rated ≤36 V. Operating temperature: -40 ... 60 °C (-40 ... 140 °F). Storage temperature: -40 ... 85 °C (-40 ... 185 °F). Connection type: 5-pin, M12 x 1 connector. Degree of protection: IP67 / IP69. Material: . HousingPET , PC (Polycarbonate): . Housing: PET , PC (Polycarbonate). Mass: 1000 g. Note: The reader must not be operated without the protective housing!. Ordering information: Mounting plate included with delivery
Specifications
General specifications
| Passage speed | ≤ 12.5 m/s v |
| Measuring length | max. 314.5 m |
| Free tolerances to code rail | horizontal: 31 mm ( ± 15.5 mm )vertical: 28 mm ( ± 14 mm ) |
| Resolution | ± 0.4 mm (1,250 positions/m) |
Functional safety related parameters
| MTTFd | 40 a |
| Mission Time (TM) | 10 a |
| Diagnostic Coverage (DC) | 0 % |
Indicators/operating means
| Operation indicator | LED green:constantly on - power onflashing - IO-Link mode |
| Data flow indicator | LED yellow: data communication active |
| Error indicator | LED red flashing: read head outside of code rail solid on: internal diagnostic test failed |
| Display | Display module, 6-digit , adaptable to installation position |
Electrical specifications
| Operating voltage | 18 ... 30 V DC UB |
| Power consumption | 12 VA P0 |
Interface
| Interface type | IO-Link |
| IO-Link revision | 1.1 |
| Device profile | Identification and Diagnosis - I&D Firmware update |
| Process data | Input: 18 Byte - Position value 32 Bit - Velocity value 16 Bit - Acceleration values 3 x 16 Bit - Ident number 16 Bit - Heartbeat 8 Bit - status data 24 Bit output: 1 Byte - control signals 8 Bit |
| Vendor ID | 1 (0x0001) |
| Device ID | 6291713 (0x600101) |
| Transfer rate | COM3 (230.4 kbits/s) |
| Min. cycle time | 1.5 ms |
| SIO mode support | no |
| Compatible master port type | Class A |
Standard conformity
| Communication interface | IEC 61131-9 / IO-Link V1.1.3 |
| Emitted interference | DIN EN 61000-6-4 , DIN EN 12015 |
| Noise immunity | DIN EN 61000-6-2 , DIN EN 12016 |
| Shock resistance | DIN EN 60068-2-27, half sine 30 g, 18 ms |
| Vibration resistance | DIN EN 60068-2-6, sine, 5 g, 10 - 2000 Hz, 10 cycles |
Approvals and certificates
| CSA approval | cCSAus Certified, General Purpose Class 2 power source |
| CCC approval | CCC approval / marking not required for products rated ≤36 V |
Ambient conditions
| Operating temperature | -40 ... 60 °C (-40 ... 140 °F) |
| Storage temperature | -40 ... 85 °C (-40 ... 185 °F) |
Mechanical specifications
| Connection type | 5-pin, M12 x 1 connector |
| Degree of protection | IP67 / IP69 |
| Material | |
| HousingPET , PC (Polycarbonate) | Housing |
| Housing | PET , PC (Polycarbonate) |
| Mass | 1000 g |
| Note | The reader must not be operated without the protective housing! |
General information
| Ordering information | Mounting plate included with delivery |
More Pepperl Fuchs parts
NewPepperl + Fuchs KFD2-GUT-EX1.D New open box
Available on requestPepperl Fuchs V19-W-BK15M-PUR-U-V19-G
Available on requestPepperl Fuchs V1SD-G-GN65M-PUR-E1S-V45-G