Pepperl Fuchs UCC4000-50GK-B26-0,15M-Y – Ultrasonic sensor. Single head system, Thread M50
Request a Quote
Quick facts
| Availability | Confirmed on request |
| Category | Diffuse Mode and Retroreflective Sensors |
| Lifecycle | Active |
| Warranty | 12-month (new) · 3-month (used/refurbished) |
Shipping & availability
When can UCC4000-50GK-B26-0,15M-Y be shipped?
UCC4000-50GK-B26-0,15M-Y is sourced on request — request a quote and we'll confirm the exact availability and shipping timeline for this specific unit.
Can I pick up UCC4000-50GK-B26-0,15M-Y in person?
Local pickup from our Groningen, Netherlands warehouse may be possible — contact us before ordering to check availability and arrange a collection time.
Is express delivery available?
Yes — mention it when you request a quote for UCC4000-50GK-B26-0,15M-Y and we'll include express shipping options in our reply.
My factory is down and I need this urgently — can you help?
For a critical breakdown, contact us directly at +31 (0)50-7110348 or sales@partnerplc.com — we can look into same-day courier or dedicated taxi/hotshot delivery for UCC4000-50GK-B26-0,15M-Y, subject to availability and destination.
Ultrasonic sensor. Single head system, Thread M50, PTFE coated transducer, Physical LIN interface, Series: -50GK, Operating voltage: 8 ... 18 V DC , ripple 10 % SS , Interface type: Physical LIN interface, Connection type: fixed cable with plug, Housing: PBT. Sensing range: 250 ... 4000 mm. Dead band: 0 ... 250 mm. Standard target plate: 100 mm x 100 mm. Transducer frequency: approx. 75 kHz. Operating voltage: 8 ... 18 V DC , ripple 10 %SS. No-load supply current: ≤ 20 mA at 12 V DC. Power consumption: ≤ 250 mW in the measurement operating mode. Time delay before availability: ≤ 95 ms. Interface type: Physical LIN interface. Transfer rate: 19.2 kBit/s (8N1). Cycle time: 80 ms. Resolution: 2.5 mm. Repeat accuracy: ≤ 0.1 % of full-scale value. Temperature influence: 3 % of full-scale value over the entire temperature range. Electromagnetic compatibility: . Directive 2014/30/EUEN IEC 60947-5-2:2020 : chapter 8.2.6.2.2, 8.2.6.2.3, 8.2.6.3 The sensor is designed to be supplied by a battery. The sensor signals are further processed in a control unit, which is also responsible for EMC protection.: . Directive 2014/30/EU: EN IEC 60947-5-2:2020 : chapter 8.2.6.2.2, 8.2.6.2.3, 8.2.6.3 The sensor is designed to be supplied by a battery. The sensor signals are further processed in a control unit, which is also responsible for EMC protection.. Ambient temperature: -25 ... 70 °C (-13 ... 158 °F). Storage temperature: -40 ... 85 °C (-40 ... 185 °F). Connection type: fixed cable with plug. Degree of protection: IP66 / IP67 ( connector excluded ). Material: . HousingPBTTransducerepoxy resin/hollow glass bead mixture; Polyurethane foam, PTFE coated: . Housing: PBT. Transducer: epoxy resin/hollow glass bead mixture; Polyurethane foam, PTFE coated. Connector: . TypeJST connector: PHR-3Number of pins3: . Type: JST connector: PHR-3. Number of pins: 3. Cable: . Cable diameter3 x 0.25 mm2MaterialPVCLengthL150 mm: . Cable diameter: 3 x 0.25 mm2. Material: PVC. Length: 150 mm. Mass: 100 g. Dimensions: . Height37 mmWidth50 mmLength50 mm: . Height: 37 mm. Width: 50 mm. Length: 50 mm. Output: Temperature compensation Address setting 7. Scope of delivery: 1 Nut plastic
Specifications
General specifications
| Sensing range | 250 ... 4000 mm |
| Dead band | 0 ... 250 mm |
| Standard target plate | 100 mm x 100 mm |
| Transducer frequency | approx. 75 kHz |
Electrical specifications
| Operating voltage | 8 ... 18 V DC , ripple 10 %SS |
| No-load supply current | ≤ 20 mA at 12 V DC |
| Power consumption | ≤ 250 mW in the measurement operating mode |
| Time delay before availability | ≤ 95 ms |
Interface
| Interface type | Physical LIN interface |
| Transfer rate | 19.2 kBit/s (8N1) |
| Cycle time | 80 ms |
Output
| Resolution | 2.5 mm |
| Repeat accuracy | ≤ 0.1 % of full-scale value |
| Temperature influence | 3 % of full-scale value over the entire temperature range |
Directive conformity
| Electromagnetic compatibility | |
| Directive 2014/30/EUEN IEC 60947-5-2:2020 : chapter 8.2.6.2.2, 8.2.6.2.3, 8.2.6.3 The sensor is designed to be supplied by a battery. The sensor signals are further processed in a control unit, which is also responsible for EMC protection. | |
| Directive 2014/30/EU | EN IEC 60947-5-2:2020 : chapter 8.2.6.2.2, 8.2.6.2.3, 8.2.6.3 The sensor is designed to be supplied by a battery. The sensor signals are further processed in a control unit, which is also responsible for EMC protection. |
Ambient conditions
| Ambient temperature | -25 ... 70 °C (-13 ... 158 °F) |
| Storage temperature | -40 ... 85 °C (-40 ... 185 °F) |
Mechanical specifications
| Connection type | fixed cable with plug |
| Degree of protection | IP66 / IP67 ( connector excluded ) |
| Material | |
| HousingPBTTransducerepoxy resin/hollow glass bead mixture; Polyurethane foam, PTFE coated | |
| Housing | PBT |
| Transducer | epoxy resin/hollow glass bead mixture; Polyurethane foam, PTFE coated |
| Connector | |
| TypeJST connector: PHR-3Number of pins3 | |
| Type | JST connector: PHR-3 |
| Number of pins | 3 |
| Cable | |
| Cable diameter3 x 0.25 mm2MaterialPVCLengthL150 mm | |
| Cable diameter | 3 x 0.25 mm2 |
| Material | PVC |
| Length | 150 mm |
| Mass | 100 g |
| Dimensions | |
| Height37 mmWidth50 mmLength50 mm | |
| Height | 37 mm |
| Width | 50 mm |
| Length | 50 mm |
Factory settings
| Output | Temperature compensation Address setting 7 |
General information
| Scope of delivery | 1 Nut plastic |
More Pepperl Fuchs parts
Available on requestPepperl Fuchs UCC2500-50GK-B26-0,15M-Y – Ultrasonic sensor. Single head system, Thread M50
Available on requestPepperl Fuchs UCC2500-50GK-B26-8MOL-Y – Ultrasonic sensor. Single head system, Thread M50
Available on requestPepperl Fuchs UCC2500-50GK-B26-V15-Y70169749 – Ultrasonic sensor. Single head system, Thread M50
Available on requestPepperl Fuchs UCC3500-30GH70-IE2R2-V15 – Ultrasonic sensor. Ultrasonic direct detection sensor
Available on requestPepperl Fuchs UCC4000-50GK-B26-V15-Y70169750 – Ultrasonic sensor. Single head system, Thread M50
Available on requestPepperl Fuchs UCC500-30GH70-IE2R2-V15 – Ultrasonic sensor. Ultrasonic direct detection sensor
Available on requestPepperl Fuchs UCC500-30GM-IU-V1 B540 – Ultrasonic sensor. Ultrasonic sensor
Available on requestPepperl Fuchs UCC6000-30GH70-IE2R2-V15 – Ultrasonic sensor. Ultrasonic direct detection sensor

