Pepperl Fuchs SJ5-K-N-6M
Request a Quote
Quick facts
| Availability | Confirmed on request |
| Category | Inductive Sensors |
| Lifecycle | active |
| Warranty | 12-month (new) · 3-month (used/refurbished) |
Shipping & availability
When can SJ5-K-N-6M be shipped?
SJ5-K-N-6M is sourced on request — request a quote and we'll confirm the exact availability and shipping timeline for this specific unit.
Can I pick up SJ5-K-N-6M in person?
Local pickup from our Groningen, Netherlands warehouse may be possible — contact us before ordering to check availability and arrange a collection time.
Is express delivery available?
Yes — mention it when you request a quote for SJ5-K-N-6M and we'll include express shipping options in our reply.
My factory is down and I need this urgently — can you help?
For a critical breakdown, contact us directly at +31 (0)50-7110348 or sales@partnerplc.com — we can look into same-day courier or dedicated taxi/hotshot delivery for SJ5-K-N-6M, subject to availability and destination.
Inductive slot sensor. Extended temperature range, Switching function: Normally closed (NC), Output type: NAMUR, Output type: 2-wire, Construction type: Slot, Series: Slot type, Type of voltage: DC, Equipment protection level Ga: IECEx PTB 11.0091X, Equipment protection level Gb: IECEx PTB 11.0091X, Equipment protection level Da: IECEx PTB 11.0091X, Equipment protection level Mb: IECEx PTB 11.0091X, Equipment protection level Ga: PTB 99 ATEX 2219 X, Equipment protection level Gb: PTB 99 ATEX 2219 X. Switching function: Normally closed (NC). Output type: NAMUR. Slot width: 5 mm. Depth of immersion (lateral): 8 ... 10 typ. 9 mm. Output type: 2-wire. Nominal voltage: 8.2 V (Ri approx. 1 kΩ). Switching frequency: 0 ... 2000 Hz. Current consumption: . Measuring plate not detectedmin. 3 mAMeasuring plate detected≤ 1 mA: . Measuring plate not detected: min. 3 mA. Measuring plate detected: ≤ 1 mA. MTTFd: 4560 a. Mission Time (TM): 20 a. Diagnostic Coverage (DC): 0 %. Standard conformity: . NAMUREN 60947-5-6:2000 IEC 60947-5-6:1999StandardsEN IEC 60947-5-2: . NAMUR: EN 60947-5-6:2000 IEC 60947-5-6:1999. Standards: EN IEC 60947-5-2. IECEx approval: . Equipment protection level GaIECEx PTB 11.0091XEquipment protection level GbIECEx PTB 11.0091XEquipment protection level DaIECEx PTB 11.0091XEquipment protection level MbIECEx PTB 11.0091X: . Equipment protection level Ga: IECEx PTB 11.0091X. Equipment protection level Gb: IECEx PTB 11.0091X. Equipment protection level Da: IECEx PTB 11.0091X. Equipment protection level Mb: IECEx PTB 11.0091X. ATEX approval: . Equipment protection level GaPTB 99 ATEX 2219 XEquipment protection level GbPTB 99 ATEX 2219 XEquipment protection level DaPTB 99 ATEX 2219 X: . Equipment protection level Ga: PTB 99 ATEX 2219 X. Equipment protection level Gb: PTB 99 ATEX 2219 X. Equipment protection level Da: PTB 99 ATEX 2219 X. UL approval: cULus Listed Load Type: Resistive Circuitry: Class 2 Power Source Enclosure Type Rating: Type 1 Supply/Switching Voltage: 8.2 V DC. Ordinary LocationE87056Hazardous LocationE501628Control drawing116-0453: . Ordinary Location: E87056. Hazardous Location: E501628. Control drawing: 116-0453. CCC approval: . Hazardous Location2020322315002306: . Hazardous Location: 2020322315002306. NEPSI approval: . NEPSI certificateGYJ16.1391X: . NEPSI certificate: GYJ16.1391X. Ambient temperature: -25 ... 100 °C (-13 ... 212 °F). Connection type: cable. Housing material: PBT. Degree of protection: IP67. Cable: . Cable diameter6 mm ± 0.2 mmBending radius> 10 x cable diameterMaterialPVCCore cross section0.75 mm2LengthL6 m: . Cable diameter: 6 mm ± 0.2 mm. Bending radius: > 10 x cable diameter. Material: PVC. Core cross section: 0.75 mm2. Length: 6 m. Dimensions: . Height31 mmWidth32 mmLength29 mm: . Height: 31 mm. Width: 32 mm. Length: 29 mm. Use in the hazardous area: see instruction manuals
Specifications
General specifications
| Switching function | Normally closed (NC) |
| Output type | NAMUR |
| Slot width | 5 mm |
| Depth of immersion (lateral) | 8 ... 10 typ. 9 mm |
| Output type | 2-wire |
Nominal ratings
| Nominal voltage | 8.2 V (Ri approx. 1 kΩ) Uo |
| Switching frequency | 0 ... 2000 Hz f |
| Current consumption | |
| Measuring plate not detectedmin. 3 mAMeasuring plate detected≤ 1 mA | Measuring plate not detected |
| Measuring plate not detected | min. 3 mA |
| Measuring plate detected | ≤ 1 mA |
Functional safety related parameters
| MTTFd | 4560 a |
| Mission Time (TM) | 20 a |
| Diagnostic Coverage (DC) | 0 % |
Compliance with standards and directives
| Standard conformity | |
| NAMUREN 60947-5-6:2000 IEC 60947-5-6:1999StandardsEN IEC 60947-5-2 | NAMUR |
| NAMUR | EN 60947-5-6:2000 IEC 60947-5-6:1999 |
| Standards | EN IEC 60947-5-2 |
Approvals and certificates
| IECEx approval | |
| Equipment protection level GaIECEx PTB 11.0091XEquipment protection level GbIECEx PTB 11.0091XEquipment protection level DaIECEx PTB 11.0091XEquipment protection level MbIECEx PTB 11.0091X | Equipment protection level Ga |
| Equipment protection level Ga | IECEx PTB 11.0091X |
| Equipment protection level Gb | IECEx PTB 11.0091X |
| Equipment protection level Da | IECEx PTB 11.0091X |
| Equipment protection level Mb | IECEx PTB 11.0091X |
| ATEX approval | |
| Equipment protection level GaPTB 99 ATEX 2219 XEquipment protection level GbPTB 99 ATEX 2219 XEquipment protection level DaPTB 99 ATEX 2219 X | Equipment protection level Ga |
| Equipment protection level Ga | PTB 99 ATEX 2219 X |
| Equipment protection level Gb | PTB 99 ATEX 2219 X |
| Equipment protection level Da | PTB 99 ATEX 2219 X |
| UL approval | cULus Listed Load Type: Resistive Circuitry: Class 2 Power Source Enclosure Type Rating: Type 1 Supply/Switching Voltage: 8.2 V DC |
| Ordinary LocationE87056Hazardous LocationE501628Control drawing116-0453 | Ordinary Location |
| Ordinary Location | E87056 |
| Hazardous Location | E501628 |
| Control drawing | 116-0453 |
| CCC approval | |
| Hazardous Location2020322315002306 | Hazardous Location |
| Hazardous Location | 2020322315002306 |
| NEPSI approval | |
| NEPSI certificateGYJ16.1391X | NEPSI certificate |
| NEPSI certificate | GYJ16.1391X |
Ambient conditions
| Ambient temperature | -25 ... 100 °C (-13 ... 212 °F) |
Mechanical specifications
| Connection type | cable |
| Housing material | PBT |
| Degree of protection | IP67 |
| Cable | |
| Cable diameter6 mm ± 0.2 mmBending radius> 10 x cable diameterMaterialPVCCore cross section0.75 mm2LengthL6 m | Cable diameter |
| Cable diameter | 6 mm ± 0.2 mm |
| Bending radius | > 10 x cable diameter |
| Material | PVC |
| Core cross section | 0.75 mm2 |
| Length | 6 m L |
| Dimensions | |
| Height31 mmWidth32 mmLength29 mm | Height |
| Height | 31 mm |
| Width | 32 mm |
| Length | 29 mm |
General information
| Use in the hazardous area | see instruction manuals |
More Pepperl Fuchs parts
NewPepperl + Fuchs KFD2-GUT-EX1.D New open box
Available on requestPepperl Fuchs V19-W-BK15M-PUR-U-V19-G