Pepperl Fuchs RJ15-N-Y52553
Request a Quote
Quick facts
| Availability | Confirmed on request |
| Category | Inductive Sensors |
| Lifecycle | active |
| Warranty | 12-month (new) · 3-month (used/refurbished) |
Shipping & availability
When can RJ15-N-Y52553 be shipped?
RJ15-N-Y52553 is sourced on request — request a quote and we'll confirm the exact availability and shipping timeline for this specific unit.
Can I pick up RJ15-N-Y52553 in person?
Local pickup from our Groningen, Netherlands warehouse may be possible — contact us before ordering to check availability and arrange a collection time.
Is express delivery available?
Yes — mention it when you request a quote for RJ15-N-Y52553 and we'll include express shipping options in our reply.
My factory is down and I need this urgently — can you help?
For a critical breakdown, contact us directly at +31 (0)50-7110348 or sales@partnerplc.com — we can look into same-day courier or dedicated taxi/hotshot delivery for RJ15-N-Y52553, subject to availability and destination.
Inductive ring sensor. Switching function: Normally closed (NC), Output type: NAMUR, Output type: 2-wire, Construction type: Ring, Series: Ring Type, Type of voltage: DC, Equipment protection level Gb: PTB 99 ATEX 2128 X, Connection type: cable, Housing material: PBT, Degree of protection: IP67, Material: PUR. Switching function: Normally closed (NC). Output type: NAMUR. Inside diameter: 15 mm. Measuring cylinder: . Diameter3 mmLength4 mm: . Diameter: 3 mm. Length: 4 mm. Output type: 2-wire. Nominal voltage: 8.2 V (Ri approx. 1 kΩ). Operating voltage: 5 ... 25 V. Switching frequency: 0 ... 1500 Hz. Current consumption: . Measuring plate not detected≥ 3 mA at nominal voltageMeasuring plate detected≤ 1 mA at nominal voltage: . Measuring plate not detected: ≥ 3 mA at nominal voltage. Measuring plate detected: ≤ 1 mA at nominal voltage. MTTFd: 9340 a. Mission Time (TM): 20 a. Diagnostic Coverage (DC): 0 %. Standard conformity: . NAMUREN 60947-5-6:2000 IEC 60947-5-6:1999StandardsEN IEC 60947-5-2: . NAMUR: EN 60947-5-6:2000 IEC 60947-5-6:1999. Standards: EN IEC 60947-5-2. ATEX approval: . Equipment protection level GbPTB 99 ATEX 2128 X: . Equipment protection level Gb: PTB 99 ATEX 2128 X. FM approval: . Control drawing116-0165: . Control drawing: 116-0165. UL approval: cULus Listed Load Type: Resistive Circuitry: Class 2 Power Source Enclosure Type Rating: Type 1 Supply/Switching Voltage: 8.2 V DC. Ambient temperature: -25 ... 70 °C (-13 ... 158 °F). Connection type: cable. Housing material: PBT. Degree of protection: IP67. Cable: . Wire end ferrulesyesCable diameter4.8 mm ± 0.2 mmBending radius> 10 x cable diameterMaterialPURColorblackNumber of cores2Core cross section0.34 mm2LengthL2 m: . Wire end ferrules: yes. Cable diameter: 4.8 mm ± 0.2 mm. Bending radius: > 10 x cable diameter. Material: PUR. Color: black. Number of cores: 2. Core cross section: 0.34 mm2. Length: 2 m. Dimensions: . Height25 mmWidth29 mmLength45 mm: . Height: 25 mm. Width: 29 mm. Length: 45 mm. Use in the hazardous area: see instruction manuals
Specifications
General specifications
| Switching function | Normally closed (NC) |
| Output type | NAMUR |
| Inside diameter | 15 mm |
| Measuring cylinder | |
| Diameter3 mmLength4 mm | Diameter |
| Diameter | 3 mm |
| Length | 4 mm |
| Output type | 2-wire |
Nominal ratings
| Nominal voltage | 8.2 V (Ri approx. 1 kΩ) Uo |
| Operating voltage | 5 ... 25 V UB |
| Switching frequency | 0 ... 1500 Hz f |
| Current consumption | |
| Measuring plate not detected≥ 3 mA at nominal voltageMeasuring plate detected≤ 1 mA at nominal voltage | Measuring plate not detected |
| Measuring plate not detected | ≥ 3 mA at nominal voltage |
| Measuring plate detected | ≤ 1 mA at nominal voltage |
Functional safety related parameters
| MTTFd | 9340 a |
| Mission Time (TM) | 20 a |
| Diagnostic Coverage (DC) | 0 % |
Compliance with standards and directives
| Standard conformity | |
| NAMUREN 60947-5-6:2000 IEC 60947-5-6:1999StandardsEN IEC 60947-5-2 | NAMUR |
| NAMUR | EN 60947-5-6:2000 IEC 60947-5-6:1999 |
| Standards | EN IEC 60947-5-2 |
Approvals and certificates
| ATEX approval | |
| Equipment protection level GbPTB 99 ATEX 2128 X | Equipment protection level Gb |
| Equipment protection level Gb | PTB 99 ATEX 2128 X |
| FM approval | |
| Control drawing116-0165 | Control drawing |
| Control drawing | 116-0165 |
| UL approval | cULus Listed Load Type: Resistive Circuitry: Class 2 Power Source Enclosure Type Rating: Type 1 Supply/Switching Voltage: 8.2 V DC |
Ambient conditions
| Ambient temperature | -25 ... 70 °C (-13 ... 158 °F) |
Mechanical specifications
| Connection type | cable |
| Housing material | PBT |
| Degree of protection | IP67 |
| Cable | |
| Wire end ferrulesyesCable diameter4.8 mm ± 0.2 mmBending radius> 10 x cable diameterMaterialPURColorblackNumber of cores2Core cross section0.34 mm2LengthL2 m | Wire end ferrules |
| Wire end ferrules | yes |
| Cable diameter | 4.8 mm ± 0.2 mm |
| Bending radius | > 10 x cable diameter |
| Material | PUR |
| Color | black |
| Number of cores | 2 |
| Core cross section | 0.34 mm2 |
| Length | 2 m L |
| Dimensions | |
| Height25 mmWidth29 mmLength45 mm | Height |
| Height | 25 mm |
| Width | 29 mm |
| Length | 45 mm |
General information
| Use in the hazardous area | see instruction manuals |
More Pepperl Fuchs parts
Available on requestPepperl Fuchs Ring switch for Lite-Ex PL 30e
Available on requestPepperl Fuchs RJ15-14-N
Available on requestPepperl Fuchs RJ15-14-N-5M
Available on requestPepperl Fuchs RJ21-E2
Available on requestPepperl Fuchs RJ21-E2-0,1M-V1
Available on requestPepperl Fuchs RJ43-E2
Available on requestPepperl Fuchs RL ID01

