Pepperl Fuchs PMI510-F110-IU-V1 – Inductive positioning system. Analog output 0 V ... 10 V/4…
Request a Quote
Quick facts
| Availability | Confirmed on request |
| Category | Inductive Positioning Systems |
| Lifecycle | active |
| Warranty | 12-month (new) · 3-month (used/refurbished) |
Shipping & availability
When can PMI510-F110-IU-V1 be shipped?
PMI510-F110-IU-V1 is sourced on request — request a quote and we'll confirm the exact availability and shipping timeline for this specific unit.
Can I pick up PMI510-F110-IU-V1 in person?
Local pickup from our Groningen, Netherlands warehouse may be possible — contact us before ordering to check availability and arrange a collection time.
Is express delivery available?
Yes — mention it when you request a quote for PMI510-F110-IU-V1 and we'll include express shipping options in our reply.
My factory is down and I need this urgently — can you help?
For a critical breakdown, contact us directly at +31 (0)50-7110348 or sales@partnerplc.com — we can look into same-day courier or dedicated taxi/hotshot delivery for PMI510-F110-IU-V1, subject to availability and destination.
Inductive positioning system. Analog output 0 V ... 10 V/4 mA ... 20 mA, Measuring range 0 ... 510 mm, Switching element function: analog, current or voltage output, Output polarity: DC, Operating voltage: 18 ... 30 V DC, Type of voltage: DC, Output type: 1 current output: 4 ... 20 mA
1 voltage output: 0 ... 10 V, UL approval: cULus Listed
Load Type: General Purpose
Circuitry: Class 2 Power Source
Enclosure Type Rating: Type 1
Supply/Switching Voltage: 30 V DC. Switching element function: analog, current or voltage output. Object distance: max. 6 mm. Measuring range: 0 ... 510 mm. Operating voltage: 18 ... 30 V DC. Reverse polarity protection: reverse polarity protected. Linearity error: ± 0.6 mm. Repeat accuracy: ± 0.5 mm. Resolution: 550 µm. Temperature drift: ± 0.7 mm (-25 °C ... 70 °C). No-load supply current: ≤ 65 mA. Operating voltage indicator: LED green. MTTFd: 183 a. Mission Time (TM): 20 a. Diagnostic Coverage (DC): 0 %. Output type: 1 current output: 4 ... 20 mA 1 voltage output: 0 ... 10 V. Load resistor: current output: ≤ 400 Ω voltage output: ≥ 1000 Ω. Short-circuit protection: voltage output: pulsing. Standard conformity: . StandardsEN 60947-5-2:2007 EN 60947-5-2/A1:2012 IEC 60947-5-2:2007 IEC 60947-5-2 AMD 1:2012: . Standards: EN 60947-5-2:2007 EN 60947-5-2/A1:2012 IEC 60947-5-2:2007 IEC 60947-5-2 AMD 1:2012. UL approval: cULus Listed Load Type: Resistive Circuitry: Class 2 Power Source Enclosure Type Rating: Type 1 Supply/Switching Voltage: 30 V DC. CCC approval: CCC approval / marking not required for products rated ≤36 V. Ambient temperature: -25 ... 70 °C (-13 ... 158 °F). Connection type: 4-pin, M12 x 1 connector. Housing length L: 550 mm. Degree of protection: IP65. Material: . HousingPA 6 / ALTargetmild steel, e. g. 1.0037, SR235JR (formerly St37-2): . Housing: PA 6 / AL. Target: mild steel, e. g. 1.0037, SR235JR (formerly St37-2). Dimensions: . Height30 mmWidth41 mmLength567 mm: . Height: 30 mm. Width: 41 mm. Length: 567 mm. Note: The data relating to accuracy only apply to a distance to the object to be detected of 1 ... 6 mm.
Specifications
General specifications
| Switching element function | analog, current or voltage output |
| Object distance | max. 6 mm |
| Measuring range | 0 ... 510 mm |
Nominal ratings
| Operating voltage | 18 ... 30 V DC UB |
| Reverse polarity protection | reverse polarity protected |
| Linearity error | ± 0.6 mm |
| Repeat accuracy | ± 0.5 mm R |
| Resolution | 550 µm |
| Temperature drift | ± 0.7 mm (-25 °C ... 70 °C) |
| No-load supply current | ≤ 65 mA I0 |
| Operating voltage indicator | LED green |
Functional safety related parameters
| MTTFd | 183 a |
| Mission Time (TM) | 20 a |
| Diagnostic Coverage (DC) | 0 % |
Analog output
| Output type | 1 current output: 4 ... 20 mA 1 voltage output: 0 ... 10 V |
| Load resistor | current output: ≤ 400 Ω voltage output: ≥ 1000 Ω |
| Short-circuit protection | voltage output: pulsing |
Compliance with standards and directives
| Standard conformity | |
| StandardsEN 60947-5-2:2007 EN 60947-5-2/A1:2012 IEC 60947-5-2:2007 IEC 60947-5-2 AMD 1:2012 | Standards |
| Standards | EN 60947-5-2:2007 EN 60947-5-2/A1:2012 IEC 60947-5-2:2007 IEC 60947-5-2 AMD 1:2012 |
Approvals and certificates
| UL approval | cULus Listed Load Type: Resistive Circuitry: Class 2 Power Source Enclosure Type Rating: Type 1 Supply/Switching Voltage: 30 V DC |
| CCC approval | CCC approval / marking not required for products rated ≤36 V |
Ambient conditions
| Ambient temperature | -25 ... 70 °C (-13 ... 158 °F) |
Mechanical specifications
| Connection type | 4-pin, M12 x 1 connector |
| Housing length L | 550 mm |
| Degree of protection | IP65 |
| Material | |
| HousingPA 6 / ALTargetmild steel, e. g. 1.0037, SR235JR (formerly St37-2) | Housing |
| Housing | PA 6 / AL |
| Target | mild steel, e. g. 1.0037, SR235JR (formerly St37-2) |
| Dimensions | |
| Height30 mmWidth41 mmLength567 mm | Height |
| Height | 30 mm |
| Width | 41 mm |
| Length | 567 mm |
| Note | The data relating to accuracy only apply to a distance to the object to be detected of 1 ... 6 mm. |
More Pepperl Fuchs parts
Available on requestPepperl Fuchs PMI360DV-F130-IU-V15 – Ind. angular measuring system. Analog output
Available on requestPepperl Fuchs PMI360DV-F130-IU2E2-V15 – Ind. angular measuring system. Analog output
Available on requestPepperl Fuchs PMI40-F90-3EP-IO-V15 – Inductive positioning system. Parameterization and…
Available on requestPepperl Fuchs PMI40-F90-U-V15 – Inductive positioning system. Measuring range 0 ... 40 mm
Available on requestPepperl Fuchs PMI80-F90-3EP-IO-V15 – Inductive positioning system. Parameterization and…
Available on requestPepperl Fuchs PMI80-F90-IE8-V15 – Inductive positioning system. Analog output 4 mA ... 20 mA
Available on requestPepperl Fuchs PMI80-F90-IU-V1 – Inductive positioning system. Analog output 0 V ... 10 V/4…
Available on requestPepperl Fuchs PMI810-F110-IU-V1 – Inductive positioning system. Analog output 0 V ... 10 V/4…


