Pepperl Fuchs PMI360D-F130-IE8-V15 – Ind. angular measuring system. Measuring range 0 ... 360°
Request a Quote
Quick facts
| Availability | Confirmed on request |
| Category | Inductive Positioning Systems |
| Lifecycle | Active |
| Warranty | 12-month (new) · 3-month (used/refurbished) |
Shipping & availability
When can PMI360D-F130-IE8-V15 be shipped?
PMI360D-F130-IE8-V15 is sourced on request — request a quote and we'll confirm the exact availability and shipping timeline for this specific unit.
Can I pick up PMI360D-F130-IE8-V15 in person?
Local pickup from our Groningen, Netherlands warehouse may be possible — contact us before ordering to check availability and arrange a collection time.
Is express delivery available?
Yes — mention it when you request a quote for PMI360D-F130-IE8-V15 and we'll include express shipping options in our reply.
My factory is down and I need this urgently — can you help?
For a critical breakdown, contact us directly at +31 (0)50-7110348 or sales@partnerplc.com — we can look into same-day courier or dedicated taxi/hotshot delivery for PMI360D-F130-IE8-V15, subject to availability and destination.
Ind. angular measuring system. Measuring range 0 ... 360°, Analog output 4 mA ... 20 mA, Adjustable switch points, Output polarity: DC, Measuring range: 360°, Type of voltage: DC, Output type: 2 switch outputs PNP, NO , reverse polarity protected , short-circuit protected, Output type: 1 current output: 4 ... 20 mA, UL approval: cULus Listed
Load Type: General Purpose
Circuitry: Class 2 Power Source
Enclosure Type Rating: Type 1
Supply/Switching Voltage: 30 V DC
Output Switching Current: 100 mA. Installation: non-flush. Measuring range: 360°. Rotational speed: max. 100 min-1. Operating voltage: 18 ... 30 V. Reverse polarity protection: reverse polarity protected. Repeat accuracy: ± 0.25 °. Resolution: 0.4°. Temperature drift: 0.02 ° / °C (-25 °C ... 70 °C). No-load supply current: ≤ 45 mA. Operating voltage indicator: LED green. MTTFd: 265 a. Mission Time (TM): 20 a. Diagnostic Coverage (DC): 0 %. Output type: 2 switch outputs PNP, NO , reverse polarity protected , short-circuit protected. Operating current: ≤ 100 mA. Voltage drop: ≤ 3 V. Short-circuit protection: pulsing. Output type: 1 current output: 4 ... 20 mA. Linearity error: ± 0.6 ° , (with original actuator). Load resistor: ≤ 400 Ω. Standard conformity: . StandardsEN 60947-5-2:2007 IEC 60947-5-2:2007: . Standards: EN 60947-5-2:2007 IEC 60947-5-2:2007. UL approval: cULus Listed Load Type: General Purpose Circuitry: Class 2 Power Source Enclosure Type Rating: Type 1 Supply/Switching Voltage: 30 V DC Output Switching Current: 100 mA. CCC approval: CCC approval / marking not required for products rated ≤36 V. Ambient temperature: -25 ... 70 °C (-13 ... 158 °F). Storage temperature: -40 ... 100 °C (-40 ... 212 °F). Connection type: 5-pin, M12 x 1 connector. Housing material: PBT. Shaft diameter: max. 27.5 mm Steel. Degree of protection: IP67. Mass: 180 g. Dimensions: . Height22 mmWidth76.5 mmLength120 mm: . Height: 22 mm. Width: 76.5 mm. Length: 120 mm
Specifications
General specifications
| Installation | non-flush |
| Measuring range | 360° |
| Rotational speed | max. 100 min-1 |
Nominal ratings
| Operating voltage | 18 ... 30 V |
| Reverse polarity protection | reverse polarity protected |
| Repeat accuracy | ± 0.25 ° |
| Resolution | 0.4° |
| Temperature drift | 0.02 ° / °C (-25 °C ... 70 °C) |
| No-load supply current | ≤ 45 mA |
| Operating voltage indicator | LED green |
Functional safety related parameters
| MTTFd | 265 a |
| Mission Time (TM) | 20 a |
| Diagnostic Coverage (DC) | 0 % |
Switching output
| Output type | 2 switch outputs PNP, NO , reverse polarity protected , short-circuit protected |
| Operating current | ≤ 100 mA |
| Voltage drop | ≤ 3 V |
| Short-circuit protection | pulsing |
Analog output
| Output type | 1 current output: 4 ... 20 mA |
| Linearity error | ± 0.6 ° , (with original actuator) |
| Load resistor | ≤ 400 Ω |
Compliance with standards and directives
| Standard conformity | |
| StandardsEN 60947-5-2:2007 IEC 60947-5-2:2007 | |
| Standards | EN 60947-5-2:2007 IEC 60947-5-2:2007 |
Approvals and certificates
| UL approval | cULus Listed Load Type: General Purpose Circuitry: Class 2 Power Source Enclosure Type Rating: Type 1 Supply/Switching Voltage: 30 V DC Output Switching Current: 100 mA |
| CCC approval | CCC approval / marking not required for products rated ≤36 V |
Ambient conditions
| Ambient temperature | -25 ... 70 °C (-13 ... 158 °F) |
| Storage temperature | -40 ... 100 °C (-40 ... 212 °F) |
Mechanical specifications
| Connection type | 5-pin, M12 x 1 connector |
| Housing material | PBT |
| Shaft diameter | max. 27.5 mm Steel |
| Degree of protection | IP67 |
| Mass | 180 g |
| Dimensions | |
| Height22 mmWidth76.5 mmLength120 mm | |
| Height | 22 mm |
| Width | 76.5 mm |
| Length | 120 mm |
More Pepperl Fuchs parts
Available on requestPepperl Fuchs PMI15V-F166-EP-IO-1M-Y70105596 – Inductive positioning system. IO-Link interface for service…
Available on requestPepperl Fuchs PMI210-F110-2U-V1-Y70137901 – Inductive positioning system. Measuring range 0 ... 210 mm
Available on requestPepperl Fuchs PMI210-F110-IU-V1 – Inductive positioning system. Analog output 0 V ... 10 V/4…
Available on requestPepperl Fuchs PMI360-F110-IU-V1 – Inductive positioning system. Analog output 0 V ... 10 V/4…
Available on requestPepperl Fuchs PMI360DV-F130-3E2-V15 – Ind. angular measuring system. 3 configurable switching…
Available on requestPepperl Fuchs PMI360DV-F130-IU-V15 – Ind. angular measuring system. Analog output
Available on requestPepperl Fuchs PMI360DV-F130-IU2E2-V15 – Ind. angular measuring system. Analog output
Available on requestPepperl Fuchs PMI40-F90-3EP-IO-V15 – Inductive positioning system. Parameterization and…