Pepperl Fuchs NMN20-18GH50-E2
Request a Quote
Quick facts
| Availability | Confirmed on request |
| Category | Inductive Sensors |
| Lifecycle | active |
| Warranty | 12-month (new) · 3-month (used/refurbished) |
Shipping & availability
When can NMN20-18GH50-E2 be shipped?
NMN20-18GH50-E2 is sourced on request — request a quote and we'll confirm the exact availability and shipping timeline for this specific unit.
Can I pick up NMN20-18GH50-E2 in person?
Local pickup from our Groningen, Netherlands warehouse may be possible — contact us before ordering to check availability and arrange a collection time.
Is express delivery available?
Yes — mention it when you request a quote for NMN20-18GH50-E2 and we'll include express shipping options in our reply.
My factory is down and I need this urgently — can you help?
For a critical breakdown, contact us directly at +31 (0)50-7110348 or sales@partnerplc.com — we can look into same-day courier or dedicated taxi/hotshot delivery for NMN20-18GH50-E2, subject to availability and destination.
Inductive sensor. Metal face proximity sensors, metal face, Switching function: Normally open (NO), Output type: PNP, Installation: non-flush, Output polarity: DC, Output type: 3-wire, Thread mold: M18, Construction type: Cylindrical, thread, Series: Cylindrical type, Type of voltage: DC, Connection type: cable TPE-S , 2 m 3 x 0.34 mm<sup>2</sup>, Housing material: Stainless steel 1.4435 / AISI 316L, Degree of protection: IP68 / IP69K. Switching function: Normally open (NO). Output type: PNP. Rated operating distance: 20 mm. Installation: non-flush. Output polarity: DC. Assured operating distance: 0 ... 16.2 mm. Reduction factor rAl: 1. Reduction factor rCu: 0.9. Reduction factor r304: 0.3 (0.6 of material thickness 2 mm). Reduction factor rSt37: 1. Output type: 3-wire. Installation conditions: . A34 mm (mild steel) 36 mm (stainless steel) 20 mm (aluminum) 22 mm (brass)B41 mmC60 mmF200 mm: . A: 34 mm (mild steel) 36 mm (stainless steel) 20 mm (aluminum) 22 mm (brass). B: 41 mm. C: 60 mm. F: 200 mm. Operating voltage: 10 ... 30 V. Switching frequency: 0 ... 200 Hz. Hysteresis: 3 ... 15 typ. 5 %. Reverse polarity protection: yes. Short-circuit protection: yes. Voltage drop: ≤ 2 V. Operating current: 0 ... 200 mA. Off-state current: ≤ 0.1 mA. No-load supply current: ≤ 10 mA. Time delay before availability: ≤ 40 ms. Switching state indicator: LED, yellow. Operating pressure statically: 60 bar (870.2 psi) max.. MTTFd: 655 a. Mission Time (TM): 20 a. Diagnostic Coverage (DC): 0 %. Standard conformity: . StandardsEN IEC 60947-5-2: . Standards: EN IEC 60947-5-2. UL approval: cULus Listed, General Purpose. CCC approval: CCC approval / marking not required for products rated ≤36 V. Ambient temperature: -25 ... 85 °C (-13 ... 185 °F). Connection type: cable TPE-S , 2 m 3 x 0.34 mm2. Housing material: Stainless steel 1.4435 / AISI 316L. Sensing face: Stainless steel 1.4435 / AISI 316L. Degree of protection: IP68 / IP69K. Mass: 112 g. Dimensions: . Length70 mmDiameter18 mm: . Length: 70 mm. Diameter: 18 mm
Specifications
General specifications
| Switching function | Normally open (NO) |
| Output type | PNP |
| Rated operating distance | 20 mm sn |
| Installation | non-flush |
| Output polarity | DC |
| Assured operating distance | 0 ... 16.2 mm sa |
| Reduction factor rAl | 1 |
| Reduction factor rCu | 0.9 |
| Reduction factor r304 | 0.3 (0.6 of material thickness 2 mm) |
| Reduction factor rSt37 | 1 |
| Output type | 3-wire |
Nominal ratings
| Installation conditions | |
| A34 mm (mild steel) 36 mm (stainless steel) 20 mm (aluminum) 22 mm (brass)B41 mmC60 mmF200 mm | A |
| A | 34 mm (mild steel) 36 mm (stainless steel) 20 mm (aluminum) 22 mm (brass) |
| B | 41 mm |
| C | 60 mm |
| F | 200 mm |
| Operating voltage | 10 ... 30 V UB |
| Switching frequency | 0 ... 200 Hz f |
| Hysteresis | 3 ... 15 typ. 5 % H |
| Reverse polarity protection | yes |
| Short-circuit protection | yes |
| Voltage drop | ≤ 2 V Ud |
| Operating current | 0 ... 200 mA IL |
| Off-state current | ≤ 0.1 mA Ir |
| No-load supply current | ≤ 10 mA I0 |
| Time delay before availability | ≤ 40 ms tv |
| Switching state indicator | LED, yellow |
Limit data
| Operating pressure statically | 60 bar (870.2 psi) max. |
Functional safety related parameters
| MTTFd | 655 a |
| Mission Time (TM) | 20 a |
| Diagnostic Coverage (DC) | 0 % |
Compliance with standards and directives
| Standard conformity | |
| StandardsEN IEC 60947-5-2 | Standards |
| Standards | EN IEC 60947-5-2 |
Approvals and certificates
| UL approval | cULus Listed, General Purpose |
| CCC approval | CCC approval / marking not required for products rated ≤36 V |
Ambient conditions
| Ambient temperature | -25 ... 85 °C (-13 ... 185 °F) |
Mechanical specifications
| Connection type | cable TPE-S , 2 m 3 x 0.34 mm2 |
| Housing material | Stainless steel 1.4435 / AISI 316L |
| Sensing face | Stainless steel 1.4435 / AISI 316L |
| Degree of protection | IP68 / IP69K |
| Mass | 112 g |
| Dimensions | |
| Length70 mmDiameter18 mm | Length |
| Length | 70 mm |
| Diameter | 18 mm |
More Pepperl Fuchs parts
NewPepperl + Fuchs KFD2-GUT-EX1.D New open box
Available on requestPepperl Fuchs V19-W-BK15M-PUR-U-V19-G
Available on requestPepperl Fuchs V1SD-G-GN65M-PUR-E1S-V45-G